Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
Conditions
Min.
Typ.
3.3
5.0
Max.
3.63
5.50
Units
VDC
• 0.5W Output Power
• Ultra-Miniature SIP Case
• 35 Standard Models
• 3,000 VDC Isolation
• >1.1 MHour MTBF
3.3 VDC Input 2.97
5 VDC Input 4.50
Input Voltage Range
12 VDC Input 10.80 12.0 13.20
24 VDC Input 21.60 24.0 26.40
48 VDC Input 43.20 48.0 52.80
20
Input Reflected Ripple Current
Input Filter
mA P - P
Internal Capacitor
• -40°C to +85°C Operation
Output
Parameter
Conditions
Min.
Typ.
3.0
1.2
Max.
Max.
Units
%
%
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
For VIN Change of 1%
See Model Selection Guide
100
0.02
mV P - P
%/°C
Momentary (0.5 Sec.)
Parameter
Conditions
Conditions
Min.
60 Seconds 3,000
500 VDC 1,000
100 kHz, 1V
Typ.
Units
VDC
M
pF
kHz
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics, See Note 3
Parameter
Radiated Emissions
Conducted Emissions
ESD
60
80
Min.
EN 55022
Typ.
Max.
Class B
Class B
Units
EN 55022
EN 61000-4-2 Criteria A; 8 kV Air/ 6 kV Contact
RS
EFT
Surge
CS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Criteria A; 10V/m
Criteria A; 2 kV
Criteria A; 0.5 kV
Criteria A; 10 Vrms
Criteria A; 1A/m
PFMF
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+85
+100
+125
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-40
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
48 VIN Models
All Other Models
0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm)
0.46 x 0.24 x 0.40 Inches (11.68 x 6.0 x 10.2 mm)
Non-Conductive Black Plastic (UL-94V0)
0.05 Oz (1.5g)
Case Size
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
Weight
Reliability Specifications
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign 1.121
Min.
Typ.
Typ.
Max.
Units
MHours
MTBF
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
Conditions
Min.
Max.
6.0
7.0
15.0
28.0
54.0
260
Units
VDC
°C
3.3 VDC Input -0.0
5 VDC Input -0.0
12 VDC Input -0.0
24 VDC Input -0.0
48 VDC Input -0.0
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Fuse
Input
Output
Capacitive
Load
Regulation
(% Typ)
Model
Efficiency
(%, Typ)
Rating
Slow-Blow
(mA)
Voltage (VDC)
Number
Current (mA)
Load
(µF, Max)
Voltage
Current
(mA, Max)
(VDC)
Nominal
3.3
3.3
3.3
3.3
3.3
3.3
3.3
5.0
5.0
5.0
5.0
5.0
5.0
5.0
12
Range
Full-Load No-Load
ME0503S-03I
ME0503S-05I
ME0503S-09I
ME0503S-12I
ME0503S-15I
ME0503S-18I
ME0503S-24I
ME0505S-03I
ME0505S-05I
ME0505S-09I
ME0505S-12I
ME0505S-15I
ME0505S-18I
ME0505S-24I
ME0512S-03I
ME0512S-05I
ME0512S-09I
ME0512S-12I
ME0512S-15I
ME0512S-18I
ME0512S-24I
ME0524S-03I
ME0524S-05I
ME0524S-09I
ME0524S-12I
ME0524S-15I
ME0524S-18I
ME0524S-24I
ME0548S-03I
ME0548S-05I
ME0548S-09I
ME0548S-12I
ME0548S-15I
ME0548S-18I
ME0548S-24I
2.97 - 3.63
2.97 - 3.63
2.97 - 3.63
2.97 - 3.63
2.97 - 3.63
2.97 - 3.63
2.97 - 3.63
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
205
216
216
201
208
208
208
132
121
128
127
130
127
134
58
54
57
58
61
61
59
31
20
25
25
25
25
25
25
20
13
15
18
22
20
25
15
10
15
20
20
15
15
8
3.3
5.0
9.0
12.0
15.0
18.0
24.0
3.3
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
76
70
70
72
73
73
73
76
83
78
79
77
79
75
72
78
73
72
69
68
71
69
73
71
71
73
73
72
60
66
62
64
62
62
61
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
500
500
500
500
500
500
500
250
250
250
250
250
250
250
150
150
150
150
150
150
150
75
75
75
75
75
75
75
50
50
50
50
50
50
5.0
9.0
12.0
15.0
18.0
24.0
3.3
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
12
12
12
12
12
12
24
24
24
24
24
24
24
48
48
48
5.0
9.0
12.0
15.0
18.0
24.0
3.3
29
8
5.0
9.0
30
30
10
8
12.0
15.0
18.0
24.0
3.3
5.0
9.0
12.0
15.0
18.0
24.0
29
29
29
17
10
10
10
6
16
6
17
6
48
48
48
48
17
6
17
6
17
6
18
10
50
Notes:
Mechanical Dimensions
1. Output load regulation is specified for a load change of 2±% to 1±±%.
2. Operation at no-load will not damage these units. However, they may not meet all specifications.
3. These converters will operate without external components. However, to meet the specified EMI
limits, a simple external input filter is required. See the input filter note below for more information.
4. All units are rated for operation at full output power to +85°C. Operation over +85°C without airflow
is not recommended. Output power should be derated linearly from 1±±% at 85°C to ±% at 1±±°C.
5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model
Selection table above for the correct rating.
Input Filter
Pin Connections
Pin
1
Description
-VIN
The filter (C1, C2, C3 & L1) shown in the figure above
is required to meet EN 55±22 level B. Recommended
component values are shown in the table at right.
Capacitor C1 is a 121±, 1±±V/ceramic, except for the
48V input which is a 1±±V/electrolytic. Capacitor C2 is a
121± 1±±V/ceramic. Capacitor C3 is a 12±6 3 kV/ceramic.
Capacitor C4 is added to meet EN 61±±±-4-4 and
EN 61±±±-4-5. This capacitor is a 47± µF, 1±±V/electro-
lytic. All components should be mounted as close to the
unit as possible.
VIN
C1
L1
C2
C3
2
+VIN
(VDC) (µF)
(µH)
(µF)
(pF)
3
-VOUT
3.3
5.0
12
2.2 18.0
2.2 18.0
2.2 18.0
4
+VOUT
For 48VDC input models the width of the
unit is ±.29 (7.5)andthe pins are set ±.±8
(2.±) from the edge of the case. These
dimensions are identified with an “*” on
the mechanical drawing
24
2.2 18.0 2.2 470
48 10.0 18.0 2.2 470
Notes:
•
•
•
All dimensions are typical in inches (mm)
Tolerance x.xx = ±±.±2 (±±.5±)
Pin 1 is marked by a “dot” or indentation on the front of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明