MG212SMR-05RI4 [MPD]

Medical Approved Compact MiniDIP, 2W DC/DC Converters;
MG212SMR-05RI4
型号: MG212SMR-05RI4
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Medical Approved Compact MiniDIP, 2W DC/DC Converters

文件: 总2页 (文件大小:235K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MG200MRRI4  
Medical Approved  
Compact MiniDIP, 2W  
DC/DC Converters  
Key Features:  
Electrical Specifications  
EN 60601 3RD Ed. Approved Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
2W Output Power  
Conditions  
Min.  
Typ.  
5.0  
Max.  
5.5  
Units  
4.0 kVrms Isolation  
5 VDC Input  
4.5  
Input Voltage Range  
12 VDC Input 10.8  
24 VDC Input 21.6  
Internal Capacitor  
12.0  
24.0  
13.2  
26.4  
VDC  
Reinforced Insulation  
1 x MOPP & 2 x MOOP per  
EN 60601-1 3RD Edition &  
ANSI/AAMI ES 60601-1  
2 µA Leakage Current Max  
Compact MiniDIP Case  
Single & Dual Outputs  
2.0 MH MTBF  
Input Filter  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Conditions  
Min.  
Typ.  
2.0  
0.1  
1.2  
Max.  
4.0  
1.0  
Units  
%
%
Dual Outputs, Balanced Loads  
VIN = Min to Max  
1.5  
%
Load Regulation, See Note 2  
Ripple & Noise (20 MHz)  
Temperature Coefficient  
Output Short Circuit  
General  
See Model Selection Guide  
See Note 3 100  
0.01  
0.5 Sec. Max (Autorecovery)  
150  
0.02  
mV P - P  
%/°C  
Parameter  
Conditions  
Min.  
60 Seconds 4,000  
300 Vrms  
Typ.  
Max.  
Units  
Vrms  
Isolation Voltage, Rated  
Reinforced Insulation Working Voltage  
Leakage Current  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
2.0  
µA  
G  
pF  
500 VDC  
100 kHz, 1V  
10  
50  
15  
80  
20  
100  
kHz  
Standard  
Criteria  
Level  
EMC  
EMS  
Complies With EN 55011 4TH Edition  
Complies With EN 60601-1-2  
Environmental  
Parameter  
Conditions  
Min.  
-25  
Typ.  
Max.  
+80  
+105  
+125  
Units  
°C  
°C  
Ambient  
Case  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Humidity  
-50  
°C  
Free Air Convection  
RH, Non-condensing  
95  
%
Physical  
Case Size  
See Mechanical Diagram (Page 2)  
Case Material  
Weight  
Non-Conductive Black Plastic (UL94-V0)  
0.18 Oz (5.1g)  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Reliability Specifications  
Parameter  
MTBF  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
IEC/EN 60601-1, EN 60601-1 3RD Edition, 1xMOPP & 2xMOPP  
ANSI/AAMI ES 60601-1 1xMOPP & 2xMOPP Recognition (UL Certificate)  
ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No.60601-1  
Min.  
2.0  
Typ.  
Max.  
Units  
MHours  
Safety Standards  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
9.0  
18.0  
30.0  
260  
Units  
VDC  
°C  
5 VDC Input  
Input Voltage Surge (1 Sec)  
12 VDC Input  
24 VDC Input  
1.5 mm From Case For 10 Sec  
Lead Temperature  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Capacitive  
Load  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Number  
Current (mA)  
Load  
(µF, Max)  
Regulation  
(%, Max)  
Voltage Current  
Current  
(VDC)  
(mA, Max) (mA, Min)  
Nominal Range Full-Load No-Load  
MG205SMR-05RI4  
MG205SMR-12RI4  
MG205SMR-15RI4  
MG205DMR-12RI4  
MG205DMR-15RI4  
MG212SMR-05RI4  
MG212SMR-12RI4  
MG212SMR-15RI4  
MG212DMR-12RI4  
MG212DMR-15RI4  
MG224SMR-05RI4  
MG224SMR-12RI4  
MG224SMR-15RI4  
MG224DMR-12RI4  
MG224DMR-15RI4  
5
5
5
5
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
606  
600  
605  
553  
542  
253  
250  
252  
224  
220  
126  
125  
126  
112  
110  
60  
60  
60  
60  
60  
30  
30  
30  
30  
30  
15  
15  
15  
15  
15  
5.0  
12.0  
15.0  
12.0  
15.0  
5.0  
12.0  
15.0  
12.0  
15.0  
5.0  
400.0  
165.0  
133.0  
83.0  
8.0  
3.0  
2.5  
1.5  
1.0  
8.0  
3.0  
2.5  
1.5  
1.0  
8.0  
3.0  
2.5  
1.5  
1.0  
330  
330  
330  
100  
100  
330  
330  
330  
100  
100  
330  
330  
330  
100  
100  
12  
10  
10  
10  
10  
12  
10  
10  
10  
10  
12  
10  
10  
10  
10  
66  
66  
66  
72  
73  
66  
66  
66  
74  
75  
66  
66  
66  
74  
75  
1,200  
1,200  
1,200  
1,200  
1,200  
500  
500  
500  
500  
500  
5
66.0  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
400.0  
165.0  
133.0  
83.0  
66.0  
400.0  
165.0  
133.0  
83.0  
250  
250  
250  
250  
12.0  
15.0  
12.0  
15.0  
66.0  
250  
Notes:  
Derating Curve  
0. The specified maximum capacitive load is for each output.  
2. Load regulation is measured for a load change of 2±% to 0±±%.  
3. When measuring output ripple, it is recommended that an external ±.47 µF ceramic capacitor be  
placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common  
for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the  
output ripple.  
4. Operation at no-load will not damage these units. However, they may not meet all specifications.  
5. For dual output units, the maximum capacitive load is given for each output.  
6. The converter should be connected to a low ac-impedance source. An input source with  
a highly inductive impedance may affect the stability of the converter. In applications  
where the converter output loading is high and input power is supplied over long lines,  
it may be necessary to use a capacitor on the input to insure start-up. In this case, it  
is recommended that a low ESR (ESR <0.±at 0±± kHz) capacitor be mounted close  
to the converter. For 5V input units a 2.2 µF is recommended, for 02V input units, a  
0.± µF; and for 24V units a ±.47 µF.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the  
table above for the correct rating.  
Mechanical Dimensions  
Pin Connections  
Pin  
Single  
Dual  
1
-Vin  
-Vin  
7
NC  
NC  
8
NC  
Common  
+Vout  
-Vout  
+Vin  
9
+Vout  
-Vout  
+Vin  
10  
16  
NC = No Connection  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = ±±.±0 (±±.25)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MG212SMR-12RI4

Medical Approved Compact MiniDIP, 2W DC/DC Converters
MPD

MG212SMR-15RI4

Medical Approved Compact MiniDIP, 2W DC/DC Converters
MPD

MG2157A

LED DOT MATRIX DISPLAY
MICRO-ELECTRO

MG2157C

LED DOT MATRIX DISPLAY
MICRO-ELECTRO

MG2158A

5 X 8 Dot Matrix LED Display, 1-Character, Green, 58.34mm, CASE D-2158S, 14 PIN
MICRO-ELECTRO

MG2158C

5 X 8 Dot Matrix LED Display, 1-Character, Green, 58.34mm, CASE D-2158S, 14 PIN
MICRO-ELECTRO

MG2194(132CQPF)

Field Programmable Gate Array, CMOS, CQFP132,
ATMEL

MG2194(196MQFP)

Field Programmable Gate Array, CMOS, PQFP196
ATMEL

MG2194(256MQFP)

Field Programmable Gate Array, CMOS, PQFP256,
ATMEL

MG2194(352MQFP)

Field Programmable Gate Array, CMOS, PQFP352,
ATMEL

MG2194E(MQFP132)

Field Programmable Gate Array, CMOS, PQFP132,
ATMEL

MG21B0R5B100CT

High capacitance in given case size
WALSIN