MI648D12ERW [MPD]
MI600ERW SERIES;型号: | MI648D12ERW |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MI600ERW SERIES |
文件: | 总4页 (文件大小:845K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MI600ERWSeries
2:1 Input, 6W,
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 6W Output Power
Conditions
12 VDC Input
Min.
9.0
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
9.0
18.0
36.0
Units
Input Voltage Range
Input Start Voltage
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
24 VDC Input
48 VDC Input
VDC
• 2:1 Input Voltage Range
• Miniature 1” x 1” Case
• 1,500 VDC Isolation
• 24 Standard Models
• Single & Dual Outputs
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Chassis Mount Option
• DIN Rail Option
VDC
Input Filter
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Cross Regulation
Ripple (20 MHz)
Pi () Filter
Conditions
Min.
Typ.
1.0
0.5
0.2
0.5
Max.
2.0
1.5
0.5
1.0
5.0
25
Units
%
%
%
%
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 5% to 100%
See Note 1
%
See Note 2
See Note 2
15
50
300
3.0
mV P - P
mV P - P
µSec
%
%/°C
%VOUT
Noise (20 MHz)
75
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Over Voltage Protection
Output Short Circuit
General
500
5.0
0.03
140
25% Load Step Change
110
120
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
1,000
300
Standard
Level
Radiated Emissions
Conducted Emissions
ESD
See Note 4
See Note 4
EN 55022
EN 55022
Class A
Class A
Criteria B; 4 kV Contact
Criteria A; 10V/m
Criteria B; 2 kV
Criteria B; 4 kV
Criteria B; 2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
RS
See Note 5
See Note 5
See Note 6
EFT
Surge
CS
Voltage Dips
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+85
+105
+125
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-55
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
Case Material
Weight
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)
Aluminum (UL94-V0)
0.46 Oz (15g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Typ.
Max.
Units
MHours
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
25.0
50.0
100.0
300
Units
VDC
°C
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Fuse
Rating
Reflected
Capacitive
Load
Model
Number
Efficiency
(%, Typ)
Ripple
Voltage (VDC)
Current (mA)
Full-Load No-Load
Voltage Current
Current
(mA, Min)
Current
(mA Typ)
Slow-Blow
(mA)
(µF, Max)
(VDC)
(mA, Max)
Nominal
12
Range
MI612S-03ERW
MI612S-05ERW
MI612S-12ERW
MI612S-15ERW
MI612S-24ERW
MI612D-05ERW
MI612D-12ERW
MI612D-15ERW
MI624S-03ERW
MI624S-05ERW
MI624S-12ERW
MI624S-15ERW
MI624S-24ERW
MI624D-05ERW
MI624D-12ERW
MI624D-15ERW
MI648S-03ERW
MI648S-05ERW
MI648S-12ERW
MI648S-15ERW
MI648S-24ERW
MI648D-05ERW
MI648D-12ERW
MI648D-15ERW
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
528
617
588
588
581
617
588
588
261
301
287
287
287
301
287
287
130
151
143
142
142
151
143
142
12
12
12
12
12
12
12
12
7
7
7
7
7
7
7
7
3
3
3
3
3
3.3
5.0
12.0
15.0
24.0
5.0
12.0
15.0
3.3
1,500
1,200
500
400
250
600
250
200
1,500
1,200
500
400
250
600
250
200
1,500
1,200
500
400
250
600
250
200
75.0
60.0
25.0
20.0
12.0
30
78
81
85
85
86
81
85
85
79
83
87
87
87
83
87
87
79
83
87
88
88
83
87
88
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
1,800
1,000
100
100
47
470
100
100
1,800
1,000
100
100
47
470
100
100
1,800
1,000
100
100
47
1,200
1,200
1,200
1,200
1,200
1,200
1,200
1,200
600
600
600
600
600
600
600
600
300
300
300
300
300
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
12
10
75.0
60.0
25.0
20.0
12.0
30
5.0
12.0
15.0
24.0
5.0
12.0
15.0
3.3
12
10
75.0
60.0
25.0
20.0
12.0
30
5.0
12.0
15.0
24.0
5.0
12.0
15.0
3
3
3
470
100
100
300
300
300
12
10
Notes:
Derating Curve
1. Cross regulation is measured on dual output models with one output at 50% load
while the other output is varied from 10% load to 100% load.
2. When measuring output ripple & noise, it is recommended that an external capacitor
(10 µF) be placed from the +VOUT to the -VOUT pins for single output units and from
each output to common for dual output models.
3. Transient recovery is measured to within a 1% error band for a load step change
of 25%.
4. With the addition of the DCFM-0x (or a similar discrete filter), all models will meet EN
55022 class B. Suggested input circuits are shown in the connection diagrams below &
on page 3. Contact the factory for more information.
5. To meet the requirements of EN 61000-4-4 ( 2 kV), external components are needed.
The connection diagrams below & on page 3 shows an external input filter that would
typically achieve this. With the addition of the DCFM-0x, EN 61000-4-4 ( 4 kV) can
be achieved. Contact the factory for more information.
6. To meet the requirements of EN 61000-4-5 ( 2 kV), external components are needed.
This can be done discretely (as shown in the connection diagrams below & on page 3),
or with the addition of the DCFM-0x. Contact the factory for more information.
7. Dual output units may be connected to provide a 10V, 24V, or 30 VDC output. To do this,
connect the load across the positive (+Vout) and negative (-Vout) outputs and float the
output common.
8. Operation at no-load will not damage these units.However,they may not meet all specifica-
tions. The recommended minimum load is given in the model selection table above.
9. It is recommended that a fuse be used on the input of a power supply for protection. See
the Model Selection table above for the correct rating.
Typical Board Layout: With DCFM-01 Input Module (See note at left)
Input noise and surge suppression modules are available for a number of
MPD DC/DC converters. An MI600xERW connection (with a DCFM-01/02)
is illustrated in the diagram at right. With this connection, the converter
will meet the specified EMI/EMS levels. Recommended values for the
components shown are:
Output
Fuse
C1
<48VDC Input >48VDC Input
See Table Above
330 µF/50V
330 µF/100V
For pricing or full technical information on these modules (DCFM-01 and
DCFM-02) please contact the factory.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Typical Connection
For applications that require meeting EMC standards,the diagram above 5. Recommended values for components are:
6. Thedrawingsbelowshowtypicalboardlayoutsforthe EMC/
EMI circuit shown above (one for single output models and
one for dual output units).
7. In many applications simply adding input/output
capacitors will enhance the input surge protection
and reduce output ripple sufficiently. The value of
the input capacitor can range from 10 µF to 330 µF,
depending on the needs of the application. The output
capacitor would typically be 10 µF.
illustrates a typical connection of the MI600xERW series. The units
do not require external components to operate as specified.Some notes
on this diagram (starting with the input circuit) are:
Component
MOV
LDM1
TVS
12 VIN
---
---
SMCJ28A
680 µF/25V
1µF/50V
4.7 µH
1nF/2 kV
1nF/2 kV
10 µF
24 VIN
S14K35
56 µH
48 VIN
S14K60
56 µH
SMCJ90A
330 µF/100V
1µF/100V
4.7 µH
1nF/2 kV
1nF/2 kV
10 µF
1. An external fuse should be used in all power module applications.
The recommended fuse is shown in the model chart on page 2.
2. To protect against a surge,an external MOV is recommended on the
input. A suggested value is given in the table at right.
3. To protect against voltage spikes, it is recommended that a TVS be
used on the input. A suggested value is given in the table at right.
4. The output filtering capacitor (C3) is a high frequency,low resistance
electrolytic capacitor. Care must be taken in choosing this capacitor
not to exceed the capacitive load specification for the unit. Voltage
derating of capacitors should be 60% or greater.
SMCJ48A
330 µF/50V
1µF/50V
4.7 µH
C1
C2
LDM2
CY1
CY2
1nF/2 kV
1nF/2 kV
10 µF
C3
C4
10 µF
10 µF
10 µF
Typical Board Layout: With External Filter/Surge Components for Single Output Unit
Typical Board Layout: With External Filter/Surge Components for Dual Output Unit
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
1
Single Output
+VIN
Pin
1
Dual Output
+VIN
2
-VIN
2
-VIN
3
+VOUT
3
+VOUT
4
5
No Pin
-VOUT
4
5
Common
-VOUT
Notes:
All dimensions are typical in inches (mm)
Pin Section Tolerance x.xxx = 0.004 ( 0.100)
General Tolerance x.xx = 0.01 ( 0.25)
Pin 1 is marked by a “dot” or indentation on the top of the unit
All MI600xERW models are available on adapters for chassis or DIN RAIL mounting. Specifications
for these adapters are shown in the diagrams below. Contact the factory for more information.
Chassis Mount Option: (-A2 added to Model No.)
DIN Rail Option: (-A4 added to Model No.)
Pin Connections
Pin Connections
Pin
1
Single Output
No Connection
-VIN
Pin
1
2
3
4
Dual Output
No Connection
-VIN
+VIN
-VOUT
Common
+VOUT
Pin
1
Single Output
No Connection
-VIN
Pin
1
2
3
4
Dual Output
No Connection
-VIN
+VIN
-VOUT
Common
+VOUT
2
2
3
+VIN
3
+VIN
4
-VOUT
4
-VOUT
5
6
No Connection
+VOUT
5
6
5
6
No Connection
+VOUT
5
6
Notes:
•
•
•
All dimensions are typical in inches (mm)
General Tolerance x.xx = 0.02 ( 0.50)
Wire Range is 24 AWG to 12 AWG
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com