MI648D12ERW [MPD]

MI600ERW SERIES;
MI648D12ERW
型号: MI648D12ERW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MI600ERW SERIES

文件: 总4页 (文件大小:845K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MI600ERWSeries  
2:1 Input, 6W,  
Ultra-Miniature  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Key Features:  
6W Output Power  
Conditions  
12 VDC Input  
Min.  
9.0  
Typ.  
12.0  
24.0  
48.0  
Max.  
18.0  
36.0  
75.0  
9.0  
18.0  
36.0  
Units  
Input Voltage Range  
Input Start Voltage  
24 VDC Input 18.0  
48 VDC Input 36.0  
12 VDC Input  
24 VDC Input  
48 VDC Input  
VDC  
2:1 Input Voltage Range  
Miniature 1” x 1” Case  
1,500 VDC Isolation  
24 Standard Models  
Single & Dual Outputs  
-40°C to +85°C Operation  
Industry Standard Pin-Out  
Chassis Mount Option  
DIN Rail Option  
VDC  
Input Filter  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Load Regulation  
Cross Regulation  
Ripple (20 MHz)  
Pi () Filter  
Conditions  
Min.  
Typ.  
1.0  
0.5  
0.2  
0.5  
Max.  
2.0  
1.5  
0.5  
1.0  
5.0  
25  
Units  
%
%
%
%
Dual Outputs, Balanced Loads  
VIN = Min to Max  
IOUT = 5% to 100%  
See Note 1  
%
See Note 2  
See Note 2  
15  
50  
300  
3.0  
mV P - P  
mV P - P  
µSec  
%
%/°C  
%VOUT  
Noise (20 MHz)  
75  
Transient Recovery Time, See Note 3  
Transient Response Deviation  
Temperature Coefficient  
Output Over Voltage Protection  
Output Short Circuit  
General  
500  
5.0  
0.03  
140  
25% Load Step Change  
110  
120  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
Typ.  
Max.  
Units  
VDC  
M  
pF  
kHz  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
1,000  
300  
Standard  
Level  
Radiated Emissions  
Conducted Emissions  
ESD  
See Note 4  
See Note 4  
EN 55022  
EN 55022  
Class A  
Class A  
Criteria B; 4 kV Contact  
Criteria A; 10V/m  
Criteria B; 2 kV  
Criteria B; 4 kV  
Criteria B; 2 kV  
Criteria A; 3 Vrms  
Criteria B; 0% - 70%  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-29  
RS  
See Note 5  
See Note 5  
See Note 6  
EFT  
Surge  
CS  
Voltage Dips  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
+25  
Max.  
+85  
+105  
+125  
Units  
°C  
°C  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-55  
°C  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
Physical  
Case Size  
Case Material  
Weight  
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)  
Aluminum (UL94-V0)  
0.46 Oz (15g)  
Reliability Specifications  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
25.0  
50.0  
100.0  
300  
Units  
VDC  
°C  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
Lead Temperature  
1.5 mm From Case for 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Fuse  
Rating  
Reflected  
Capacitive  
Load  
Model  
Number  
Efficiency  
(%, Typ)  
Ripple  
Voltage (VDC)  
Current (mA)  
Full-Load No-Load  
Voltage Current  
Current  
(mA, Min)  
Current  
(mA Typ)  
Slow-Blow  
(mA)  
F, Max)  
(VDC)  
(mA, Max)  
Nominal  
12  
Range  
MI612S-03ERW  
MI612S-05ERW  
MI612S-12ERW  
MI612S-15ERW  
MI612S-24ERW  
MI612D-05ERW  
MI612D-12ERW  
MI612D-15ERW  
MI624S-03ERW  
MI624S-05ERW  
MI624S-12ERW  
MI624S-15ERW  
MI624S-24ERW  
MI624D-05ERW  
MI624D-12ERW  
MI624D-15ERW  
MI648S-03ERW  
MI648S-05ERW  
MI648S-12ERW  
MI648S-15ERW  
MI648S-24ERW  
MI648D-05ERW  
MI648D-12ERW  
MI648D-15ERW  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
528  
617  
588  
588  
581  
617  
588  
588  
261  
301  
287  
287  
287  
301  
287  
287  
130  
151  
143  
142  
142  
151  
143  
142  
12  
12  
12  
12  
12  
12  
12  
12  
7
7
7
7
7
7
7
7
3
3
3
3
3
3.3  
5.0  
12.0  
15.0  
24.0  
5.0  
12.0  
15.0  
3.3  
1,500  
1,200  
500  
400  
250  
600  
250  
200  
1,500  
1,200  
500  
400  
250  
600  
250  
200  
1,500  
1,200  
500  
400  
250  
600  
250  
200  
75.0  
60.0  
25.0  
20.0  
12.0  
30  
78  
81  
85  
85  
86  
81  
85  
85  
79  
83  
87  
87  
87  
83  
87  
87  
79  
83  
87  
88  
88  
83  
87  
88  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
1,800  
1,000  
100  
100  
47  
470  
100  
100  
1,800  
1,000  
100  
100  
47  
470  
100  
100  
1,800  
1,000  
100  
100  
47  
1,200  
1,200  
1,200  
1,200  
1,200  
1,200  
1,200  
1,200  
600  
600  
600  
600  
600  
600  
600  
600  
300  
300  
300  
300  
300  
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
48  
12  
10  
75.0  
60.0  
25.0  
20.0  
12.0  
30  
5.0  
12.0  
15.0  
24.0  
5.0  
12.0  
15.0  
3.3  
12  
10  
75.0  
60.0  
25.0  
20.0  
12.0  
30  
5.0  
12.0  
15.0  
24.0  
5.0  
12.0  
15.0  
3
3
3
470  
100  
100  
300  
300  
300  
12  
10  
Notes:  
Derating Curve  
1. Cross regulation is measured on dual output models with one output at 50% load  
while the other output is varied from 10% load to 100% load.  
2. When measuring output ripple & noise, it is recommended that an external capacitor  
(10 µF) be placed from the +VOUT to the -VOUT pins for single output units and from  
each output to common for dual output models.  
3. Transient recovery is measured to within a 1% error band for a load step change  
of 25%.  
4. With the addition of the DCFM-0x (or a similar discrete filter), all models will meet EN  
55022 class B. Suggested input circuits are shown in the connection diagrams below &  
on page 3. Contact the factory for more information.  
5. To meet the requirements of EN 61000-4-4 ( 2 kV), external components are needed.  
The connection diagrams below & on page 3 shows an external input filter that would  
typically achieve this. With the addition of the DCFM-0x, EN 61000-4-4 ( 4 kV) can  
be achieved. Contact the factory for more information.  
6. To meet the requirements of EN 61000-4-5 ( 2 kV), external components are needed.  
This can be done discretely (as shown in the connection diagrams below & on page 3),  
or with the addition of the DCFM-0x. Contact the factory for more information.  
7. Dual output units may be connected to provide a 10V, 24V, or 30 VDC output. To do this,  
connect the load across the positive (+Vout) and negative (-Vout) outputs and float the  
output common.  
8. Operation at no-load will not damage these units.However,they may not meet all specifica-  
tions. The recommended minimum load is given in the model selection table above.  
9. It is recommended that a fuse be used on the input of a power supply for protection. See  
the Model Selection table above for the correct rating.  
Typical Board Layout: With DCFM-01 Input Module (See note at left)  
Input noise and surge suppression modules are available for a number of  
MPD DC/DC converters. An MI600xERW connection (with a DCFM-01/02)  
is illustrated in the diagram at right. With this connection, the converter  
will meet the specified EMI/EMS levels. Recommended values for the  
components shown are:  
Output  
Fuse  
C1  
<48VDC Input >48VDC Input  
See Table Above  
330 µF/50V  
330 µF/100V  
For pricing or full technical information on these modules (DCFM-01 and  
DCFM-02) please contact the factory.  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
www.micropowerdirect.com  
Typical Connection  
For applications that require meeting EMC standards,the diagram above 5. Recommended values for components are:  
6. Thedrawingsbelowshowtypicalboardlayoutsforthe EMC/  
EMI circuit shown above (one for single output models and  
one for dual output units).  
7. In many applications simply adding input/output  
capacitors will enhance the input surge protection  
and reduce output ripple sufficiently. The value of  
the input capacitor can range from 10 µF to 330 µF,  
depending on the needs of the application. The output  
capacitor would typically be 10 µF.  
illustrates a typical connection of the MI600xERW series. The units  
do not require external components to operate as specified.Some notes  
on this diagram (starting with the input circuit) are:  
Component  
MOV  
LDM1  
TVS  
12 VIN  
---  
---  
SMCJ28A  
680 µF/25V  
1µF/50V  
4.7 µH  
1nF/2 kV  
1nF/2 kV  
10 µF  
24 VIN  
S14K35  
56 µH  
48 VIN  
S14K60  
56 µH  
SMCJ90A  
330 µF/100V  
1µF/100V  
4.7 µH  
1nF/2 kV  
1nF/2 kV  
10 µF  
1. An external fuse should be used in all power module applications.  
The recommended fuse is shown in the model chart on page 2.  
2. To protect against a surge,an external MOV is recommended on the  
input. A suggested value is given in the table at right.  
3. To protect against voltage spikes, it is recommended that a TVS be  
used on the input. A suggested value is given in the table at right.  
4. The output filtering capacitor (C3) is a high frequency,low resistance  
electrolytic capacitor. Care must be taken in choosing this capacitor  
not to exceed the capacitive load specification for the unit. Voltage  
derating of capacitors should be 60% or greater.  
SMCJ48A  
330 µF/50V  
1µF/50V  
4.7 µH  
C1  
C2  
LDM2  
CY1  
CY2  
1nF/2 kV  
1nF/2 kV  
10 µF  
C3  
C4  
10 µF  
10 µF  
10 µF  
Typical Board Layout: With External Filter/Surge Components for Single Output Unit  
Typical Board Layout: With External Filter/Surge Components for Dual Output Unit  
MicroPower Direct  
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
www.micropowerdirect.com  
Mechanical Dimensions  
Pin Connections  
Pin  
1
Single Output  
+VIN  
Pin  
1
Dual Output  
+VIN  
2
-VIN  
2
-VIN  
3
+VOUT  
3
+VOUT  
4
5
No Pin  
-VOUT  
4
5
Common  
-VOUT  
Notes:  
All dimensions are typical in inches (mm)  
Pin Section Tolerance x.xxx = 0.004 ( 0.100)  
General Tolerance x.xx = 0.01 ( 0.25)  
Pin 1 is marked by a “dot” or indentation on the top of the unit  
All MI600xERW models are available on adapters for chassis or DIN RAIL mounting. Specifications  
for these adapters are shown in the diagrams below. Contact the factory for more information.  
Chassis Mount Option: (-A2 added to Model No.)  
DIN Rail Option: (-A4 added to Model No.)  
Pin Connections  
Pin Connections  
Pin  
1
Single Output  
No Connection  
-VIN  
Pin  
1
2
3
4
Dual Output  
No Connection  
-VIN  
+VIN  
-VOUT  
Common  
+VOUT  
Pin  
1
Single Output  
No Connection  
-VIN  
Pin  
1
2
3
4
Dual Output  
No Connection  
-VIN  
+VIN  
-VOUT  
Common  
+VOUT  
2
2
3
+VIN  
3
+VIN  
4
-VOUT  
4
-VOUT  
5
6
No Connection  
+VOUT  
5
6
5
6
No Connection  
+VOUT  
5
6
Notes:  
All dimensions are typical in inches (mm)  
General Tolerance x.xx = 0.02 ( 0.50)  
Wire Range is 24 AWG to 12 AWG  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MI648D15ERU

MI600ERU SERIES
MPD

MI648D15ERW

MI600ERW SERIES
MPD

MI648S03ERU

MI600ERU SERIES
MPD

MI648S03ERW

MI600ERW SERIES
MPD

MI648S05ERW

MI600ERW SERIES
MPD

MI648S12ERU

MI600ERU SERIES
MPD

MI648S12ERW

MI600ERW SERIES
MPD

MI648S15ERU

MI600ERU SERIES
MPD

MI648S15ERW

MI600ERW SERIES
MPD

MI648S24ERU

MI600ERU SERIES
MPD

MI648S24ERW

MI600ERW SERIES
MPD

MI910

Supports CRT, LVDS, optional DVI
ETC