ML348S-24RU [MPD]
Ultra-Compact, 3W Wide 4:1 Input, SMT DC/DC Con vert ers;型号: | ML348S-24RU |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Ultra-Compact, 3W Wide 4:1 Input, SMT DC/DC Con vert ers |
文件: | 总2页 (文件大小:687K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ML300RUSeries
Ultra-Compact, 3W
Wide 4:1 Input, SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
24 VDC Input
Min.
9.0
Typ.
24.0
48.0
6.0
Max.
36.0
75.0
8.5
17.0
8.0
Units
Key Features:
• 3W Output Power
• Ultra-Compact SMT Case
• Wide 4:1 Input
Input Voltage Range
VDC
48 VDC Input 18.0
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
4.5
8.5
Start Up Voltage
VDC
12.0
• 1,500 VDC Isolation
Under Voltage Shutdown
VDC
mW
16.0
2,000
• Single & Dual Outputs
Short Circuit Input Power
Input Filter
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
ꢀ (Pi) Filter - Meets EN 55022 Class A
• -40ºC to +80ºC Operation
• 16 Standard Models
Conditions
Min.
Typ.
Max.
2.0
2.0
1.0
1.2
Units
%
• Tight Line/Load Regulation
• Available on Tape/Reel
Dual Output, Balanced Loads
For VIN = Min to Max
For IOUT = 15% to 100%
See Note 2
1.0
0.5
0.5
50
300
3
%
%
mV P - P
µS
%
%/ºC
%
Load Regulation
Ripple & Noise (20 MHz)
Transient Response Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Overload Protection
Output Short Circuit
General
100
600
25% Load Step Change
0.01
150
0.02
Foldback Type
Continuous (Autorecovery)
110
Parameter
Conditions
Conditions
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
M
pF
kHz
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off, See Note 4
Parameter
350
350
500
Min.
2.5
-0.7
Typ.
Max.
5.5
0.8
5
Units
VDC
VDC
mA
Supply On
Supply Off
Standby Input Current
Control Common
Environmental
Parameter
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Cooling
Referenced to Negative Input (pin 1)
Min.
-40
Typ.
Max.
+80
+105
+125
Units
ºC
ºC
Ambient
Case
-50
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
See Mechanical Drawing (Page 2)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
Weight
Reliability Specifications
Parameter
Non-Conductive Black Plastic (UL94-V0)
0.14 Oz (4.2g)
Conditions
Min.
Typ.
Max.
Units
kHours
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
300
A random waveform 1~200 Hz/0.52 Grms, 30 min. on each axis
(X, Y, Z) and 2~300 Hz/1.05 Grms, 30 min. on each axis (X, Y, and Z)
Shock & Vibration
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Moisture Sensitivity Level (MSL)
Absolute Maximum Ratings
Parameter
IPC/JEDEC J-STD-020D.1
Level 2
Conditions
Min.
Typ.
Max.
50.0
100.0
245
Units
VDC
24 VDC Input
48 VDC Input
See Note 5
Input Voltage Surge (1 Sec)
Peak Reflow Temperature
Lead Temperature
ºC
ºC
1.5 mm From Case For 10 Sec.
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Output
Input
Output
Fuse Rating
Slow-Blow
(mA)
Model
Number
Efficiency Capacitive
Voltage (VDC)
Current (mA)
Voltage Current
Current
(mA, Min)
(%, Typ)
Load
(VDC)
(mA, Max)
Nominal
24
Range
Full-Load No-Load
(µF, Max)
ML324S-03RU
ML324S-05RU
ML324S-12RU
ML324S-15RU
ML324S-24RU
ML324D-05RU
ML324D-12RU
ML324D-15RU
ML348S-03RU
ML348S-05RU
ML348S-12RU
ML348S-15RU
ML348S-24RU
ML348D-05RU
ML348D-12RU
ML348D-15RU
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
110
160
156
156
156
162
156
156
55
30
30
30
30
30
30
30
30
20
20
20
20
20
20
20
20
3.3
5.0
12.0
15.0
24.0
5.0
12.0
15.0
3.3
600
600
250
200
125
300
125
100
600
600
250
200
125
300
125
100
90
90
38
30
19
45
19
15
90
90
38
30
19
45
19
15
75
78
80
80
80
77
80
80
75
78
80
80
80
77
80
80
220
220
47
47
47
47
47
47
220
220
47
47
47
47
47
47
800
800
800
800
800
800
800
800
400
400
400
400
400
400
400
400
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
80
78
78
78
5.0
12.0
15.0
24.0
5.0
12.0
15.0
81
78
78
Notes:
Derating Curve, 3.3V & 5V Outputs
1. The specified maximum capacitive load is for
each output.
seconds at 217 °C. For more information, please
contact the factory.
2. When measuring output ripple, it is recommend- 6. Operation at no-load will not damage these units.
ed that an external 0.47 µF ceramic capacitor However, they may not meet all specifications.
be placed from +VOUT to -VOUT for single output 7. The converter should be connected to a low
models or from each output to common for dual
output models. For noise sensitive applications,
the use of 3.3 µF capacitors will reduce the
output ripple.
3. Transient recovery is measured to within a 1% error
band for a load step change of 75% to 100%.
4. The maximum control current at the on/off input (pin
2) during a logic high (+5V) is 400 µA.The maximum
controlcurrenttotheon/offpinatlogiclow(0V)is-400
µA. If the on/off pin is left open, the unit operates. If
grounded, the unit will shut off.
ac-impedance source. An input source with a
highly inductive impedance may affect the sta-
bility of the converter. In applications where the
converter output loading is high and input power
is supplied over long lines, it may be necessary
to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR
(<1.0 at 100 kHz) capacitor be mounted close
to the converter. For 24V input units a 4.7 µF is
recommended and for 48V input models, a 2.2 µF.
8. It is recommended that a fuse be used on the
input of a power supply for protection. See the
table above for the correct rating.
5. The recommended reflow settings are a peak
temperature of 245 °C for a maximum period
(TPK) of 10S and a time above liquidous (TL) of <60
Mechanical Dimensions
Derating Curve, All Other Outputs
Board Layout
Pin Connections
Pin
Single
Dual
1
2
-VIN
-VIN
Remote On/Off
7
NC
NC
NC
Common
+VOUT
-VOUT
8
9
+VOUT
-VOUT
+VIN
10
16
+VIN
NC = No connection
Notes:
•
•
•
All dimensions are typical in inches (mm)
Tolerance x.xx = 0.01 ( 0.25)
Pin 1 is marked by a “dot” or indentation on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
ML350RAT5N4GLH
General Purpose Inductor, 0.0054uH, 2%, 1 Element, Air-Core, SMD, 1014, CHIP, 1410
COILCRAFT
ML350RAT5N4JLN
General Purpose Inductor, 0.0054uH, 5%, 1 Element, Air-Core, SMD, 1014, CHIP, 1410
COILCRAFT
©2020 ICPDF网 联系我们和版权申明