MPM-03S-12MM [MPD]
3W Output Power;型号: | MPM-03S-12MM |
厂家: | MICROPOWER DIRECT, LLC |
描述: | 3W Output Power |
文件: | 总2页 (文件大小:532K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPM-03MM
Miniature 1 x 1 Inch
3W, Single Output
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 3W Output Power
Parameter
Conditions
Min.
85
120
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
• Miniature 1 x 1 Inch Case
• Universal 85-264 VAC Input
• EN 60950 Approved
• Six Standard Models
• Meets EN 55022 B
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
115 VAC
15.0
25.0
150
Inrush Current, See Note 1
A Pk
mW
230 VAC
See Note 2
No Load Power Consumption
Output
Parameter
• Meets IEC Safety Class II
Conditions
Min.
Typ.
Max.
Units
• >1.20 MHour MTBF
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Overshoot
See Model Selection Guide
See Model Selection Guide
2.0
1.0
1.0
70
%
%
%
m V P-P
mS
%/°C
%VOUT
%VOUT
VIN = Min to Max
IOUT = 0% to 100%
115 VAC
8.0
0.05
190
5.0
See Note 3
125
Short Circuit Protection, See Note 4
Overload Protection
General
Continuous (Auto-Recovery)
See Note 5 135
150
%W
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
M
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Input to Output, 60S 3,000
500 VDC 100
65
kHz
Standard
Criteria
Level
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
EN 55014, EN 55024
Class B
Class B
8 kV Air
10V/m
2 kV
1 kV
10 Vrms
30A/m
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
A
A
A
A
A
A
A
B
30% 10 mS
95% 5,000 mS
Interruptions
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Conditions
Min.
-25
-40
Typ.
+25
Max.
+70
+85
Units
°C
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing 95
Humidity
%
Physical
Case Size
T: (781) 344-8226
F: (781) 344-8481
See Mechanical Diagram (Page 2)
Case Material
Weight
Non-Conductive Black Plastic (UL94-V0)
0.59 Oz (17.4g)
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 1.20
MHours
Safety Standards
Safety Class
EN 60950
IEC 60536 Class II
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Current (mA)
Fuse
Current
Capacitive
Model
Number
Efficiency
(%, Typ)
Rating
Slow-Blow
(mA)
(mA Typ)
Load
Voltage
(VDC)
(µF Max)
Other outputs may be available
Contact the factory for details at:
sales@micropowerdirect.com
115 VAC
Max.
Min.
Peak
MPM-03S-03MM
MPM-03S-05MM
MPM-03S-09MM
MPM-03S-12MM
MPM-03S-15MM
MPM-03S-24MM
62
61
57
56
56
56
3.3
5.0
9.0
12.0
15.0
24.0
900
600
333
250
200
125
0.0
0.0
0.0
0.0
0.0
0.0
1,170
780
430
320
260
160
70
72
77
78
78
78
1,200
820
470
330
270
180
1,000
1,000
1,000
1,000
1,000
1,000
Derating Curve
Notes:
1. Inrush current is given for a cold start at 25°C.
2. No load power consumption meets the standby power consumption limits in
the European ERP Directive 2009/125/EC.
3. Over voltage protection is provided by a zener diode clamp.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit
with auto-recovery. A long-term overload could damage the unit.
6. Operation at no-load will not damage these units. However, they may not meet
all specifications.
7. Peak load is specified as lasting <30s with a maximum duty cycle of 10%
The average power should not exceed the maximum power rating.
8. It is recommended that an external slow blow fuse also be used on the input
for protection. See the table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
Function
1
2
3
4
5
AC-Neutral
AC-Line
No Connection
-VOUT
+VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号: