Series
MPM-05MM
Miniature 1 x 1 Inch
5W, Single Output
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 5W Output Power
Parameter
Conditions
Min.
85
120
47
Typ.
Max.
264
370
440
Units
VAC
VDC
Hz
• Miniature 1 x 1 Inch Case
• Universal 85-264 VAC Input
• EN 60950 Approved
• Chassis Mount Option
• Meets EN 55022 B
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
115 VAC
20.0
40.0
300
Inrush Current, See Note 1
A Pk
mW
230 VAC
See Note 2
No Load Power Consumption
Output
Parameter
• Meets IEC Safety Class II
Conditions
Min.
Typ.
Max.
Units
• >1.20 MHour MTBF
Output Voltage
Output Current
See Model Selection Guide
See Model Selection Guide
Output Voltage Accuracy
Line Regulation
Load Regulation
2.0
1.0
1.0
60
%
%
%
VIN = Min to Max
IOUT = 0% to 100%
3.3 & 5 VDC Out Models
All Other Models
115 VAC
m V P-P
% V P-P of VOUT
Ripple & Noise, See Note 3
1.0
8.0
40
Hold-Up Time
mS
230 VAC
Temperature Coefficient
Over Voltage Protection
Overshoot
0.05
190
5.0
%/°C
%VOUT
%VOUT
See Note 4
125
Short Circuit Protection, See Note 5
Overload Protection
General
Continuous (Autorecovery)
See Note 6 135
150
%W
Parameter
Conditions
Input to Output 3,000
500 VDC 100
Min.
Typ.
Max.
Units
VAC
M
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
65
kHz
Standard
Criteria
Level
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
EN 55014, EN 55024
EN 55022
Class B
Class B
8 kV Air/ 4 kV Contact
10V/m
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
A
A
A
A
A
A
A
B
2 kV
1 kV
10 Vrms
30A/m
30% 10 mS
95% 500 mS
Interruptions
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Conditions
Min.
-25
-40
Typ.
+25
Max.
+70
+85
Units
°C
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Humidity
%
Physical
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Case Size
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL94-V0)
Case Material
Board Mount
Chassis Mount
0.69 Oz (19.7g)
0.85 Oz (19.7g)
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
MIL HDBK 217F, 25°C, Gnd Benign 1.20
EN 60950
Min.
Typ.
Max.
Units
MHours
IEC 60536 Class II
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Current (mA)
Fuse
Current
Capacitive
Model
Number
Efficiency
(%, Typ)
Rating
Slow-Blow
(mA)
(mA Typ)
Load
Voltage
(µF Max)
(VDC)
115 VAC
Max.
Min.
Peak
Other outputs may be available
Contact the factory for details at:
sales@micropowerdirect.com
MPM-05S-03MM (C)
MPM-05S-05MM (C)
MPM-05S-09MM (C)
MPM-05S-12MM (C)
MPM-05S-15MM (C)
MPM-05S-24MM (C)
MPM-05S-48MM (C)
117
108
106
106
104
104
102
3.3
5.0
9.0
12.0
15.0
24.0
48.0
1,515
1,000
555
416
333
0.0
0.0
0.0
0.0
0.0
0.0
0.0
1,970
1,300
721
540
433
74
80
82
82
83
83
85
2,200
1,000
300
160
100
43
1,000
1,000
1,000
1,000
1,000
1,000
1,000
208
104
270
135
10
Derating Curve
Notes:
1. Inrush current is given for a cold start at 25°C.
2. No load power consumption meets the standby power consumption limits in
the European ERP Directive 2009/125/EC.
3. Ripple & Noise is specified over a range of 0 - 20 MHz. It is measured with a
1 µF/50V MLCC connected from +VOUT to -VOUT.
4. Over voltage protection is provided by a zener diode clamp.
5. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
6. Output overload protection is provided by a fold back current limiting circuit
with auto-recovery. A long-term overload could damage the unit.
7. Operation at no-load will not damage these units. However, they may not meet
all specifications.
8. Peak load is specified as lasting <30s with a maximum duty cycle of 10%
The average power should not exceed the maximum power rating.
9. It is recommended that an external slow blow fuse also be used on the input
for protection. See the table above for the correct rating.
Mechanical Dimensions
Board Mount
Chassis Mount
Pin Connections
Pin
Function
1
2
3
4
5
AC-Neutral
AC-Line
No Connection
-VOUT
+VOUT
To order a chassis mount version, add a “C” to the model number
(i.e. MPM-05S-15MMC)
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明