MPM-10D-12IS [MPD]
Chassis Mount, 15W Single, Dual & Triple Out AC/DC Power Supplies; 底座安装, 15W单,双和三输出AC / DC电源型号: | MPM-10D-12IS |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Chassis Mount, 15W Single, Dual & Triple Out AC/DC Power Supplies |
文件: | 总2页 (文件大小:241K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPM-10IS
Board Mount, 10W
Single & Dual Output
AC/DC Power Supplies
Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 10W Output Power
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
• Universal 85-265 VAC Input
• EN 60950 Approved
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Single and Dual Outputs
• Meets EN55022 B
Conditions
Min.
85
47
Typ.
Max.
265
440
Units
VAC
Hz
See Model Selection Guide
115 VAC
230 VAC
10.0
20.0
Inrush Current
A Pk
EMI
Meets CISPR Pub. 22/FCC Class B
• >300 kHour MTBF
115 VAC
230 VAC
0.1
0.3
Safety Ground Leakage Current
mA
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage
Output Current
See Model Selection Guide
See Model Selection Guide
Output Voltage Accuracy
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
1.0
2.0
1.0
1.0
5.0
1.8
1.0
%
%
%
%
VIN = Min to Max
IO = Min to Max
IO = Min to Max
0.5
0.5
2.5
1.5
0.8
20
3.3V & 5.0 VDC Output
All Other Outputs
115 VAC, 60 Hz
Ripple & Noise (20 MHz)
%VP-P of VO
Hold-Up Time
mSec
%/°C
% of VO
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 3
Overload Protection, Note 4
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
0.02
120
Zener Diode Clamp
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Conditions
Input to Output 3,000
Input to Output, Flash Tested For 60S 4,700
Min.
Typ.
Max.
Units
VAC
VAC
M
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
100
EN 55022 Level B
IEC/EN 61000-4-2 Level 3
IEC/EN61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-4 Level 3 2 kV
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
100
kHz
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
-25
-40
Typ.
+25
Max.
+71
+85
Units
°C
°C
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
2.52 x 1.77 x 0.75 Inches (64.0 x 45.0 x 19.0 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
3.23 Oz (92g)
Case Material
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
Safety Standards
Safety Approvals
Safety Class
IEN 60950, IEC 60950
IEN 60950, IEC 60950
IEC 61140 Class II
Model Selection Guide
Input
Output 1 (Vout 1)
Current (A)
Output 2 (Vout 2)
Current (A)
Max. Min.
Capacitive
Load
(µF, Max)
Model
Number
Efficiency
(%, Typ)
Current (A)
Voltage
Voltage
(VDC)
(VDC)
115 VAC 230 VAC
Max.
Min.
MPM-10S-03IS
MPM-10S-05IS
MPM-10S-12IS
MPM-10S-15IS
MPM-10S-24IS
MPM-10D-12IS
MPM-10D-15IS
0.137
0.199
0.191
0.191
0.190
0.172
0.169
0.075
0.075
0.075
0.075
0.075
0.075
0.075
3.3
5.0
2.000
2.000
0.833
0.666
0.416
+0.380
+0.300
0.200
0.200
0.083
0.066
0.042
+0.038
+0.030
3,900
3,300
2,200
2,200
1,000
1,000
1,000
70
73
76
76
76
77
77
12.0
15.0
24.0
+12.0
+15.0
-12.0
-15.0
-0.380 -0.038
-0.300 -0.030
Derating Curve
Other output combinations are available
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. Load regulation is measured for an output change of 0% to 100% at
nominal input line. For multiple output models, the loads are balanced.
2. Operation at no-load will not damage these units. However, they may
not meet all specifications.
3. Output short circuit protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is removed.
4. Output overload protection is provided by a fold back current limiting
circuit.
5. The MPM-10IS series includes a built-in 2A/250 VAC fuse. It is recom-
mended that an external 1.5A slow blow fuse also be used on the input
for protection.
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
2
3
4
5
AC-Neutral AC-Neutral
AC-Line
-Vo
AC-Line
-Vo
NC
Common
+Vo
+Vo
NP = No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明