MPM-24MD-12xx [MPD]
24W Output Power;型号: | MPM-24MD-12xx |
厂家: | MICROPOWER DIRECT, LLC |
描述: | 24W Output Power |
文件: | 总4页 (文件大小:1252K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPM-24M
Medical Approved, 24W
Single & Dual Output
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 24W Output Power
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• EN 60601-1 3RD Edition
• Universal 85-264 VAC Input
• EN 60950 Approved
• Reinforced Insulation
• Meets IEC Safety Class II
• Low Leakage Current
• Single and Dual Outputs
• Meets UL 508
Parameter
Conditions
Min.
85
120
47
Typ.
Max.
264
370
440
Units
VAC
VDC
Hz
Input Voltage Range
Input Frequency
115 VAC
230 VAC
20
40
Inrush Current, See Note 2
A Pk
W
No Load Power Consumption
Output
Parameter
Output Voltage Accuracy
Line Regulation
0.3
Conditions
Min.
Typ.
2.0
0.5
0.5
2.5
1.5
1.0
20
Max.
Units
%
%
VIN = Min to Max
Single Output
Load Regulation, IO = Min to Max
Ripple & Noise (20 MHz), See Note 3
Hold-Up Time
%
%VP-P of VO
mS
Dual Output
5.0 VDC Output
All Other Outputs
115 VAC, 60 Hz
230 VAC, 50 Hz
1.8
1.3
Chassis Mount Models
& DIN Rail Mount
Option Available!
80
Temperature Coefficient
Over Voltage Protection
Overshoot
Overload Protection
Over Temperature Protection
Short Circuit Protection, See Note 7
General
0.02
120
%/°C
% of VO
%
% INOM
°C
See Note 4
5
See Note 5 105
See Note 6
90
Continuous (Autorecovery)
Parameter
Isolation Voltage (Reinforced)
Leakage Current
Isolation Resistance
Switching Frequency
Environmental
Conditions Min. Typ.
Max.
Units
VAC rms
µA
M⍀
kHz
Input to Output 4,000
500 VDC 1,000
80
132
Parameter
Radiated Emissions
Conducted Emissions
Standard
EN 55014, EN 55024
EN 55022
Criterea
Level
Class B
Class B
A
A
A
A
A
A
A
A
B
8 kV Air
4 kV Contact
10 V/m
2 kV
1 kV
10 Vrms
30 A/M
30% 10 mS
95% 5,000 mS
ESD
EN 61000-4-2
RS
EFT
Surge
CS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
PFM
Voltage Dips
Interruptions
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling, See Note 8
Humidity
Physical
Case Size
Case Material
Reliability Specifications
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
Typ.
+25
Max.
+80
+95
Units
°C
°C
Ambient
-40
-40
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
%
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
See Mechanical Diagrams (Pages 3 & 4)
Non-Conductive Plastic Resin (UL94-V0)
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
400
kHours
Safety Standards
UL 60950, EN 60950
Safety Class
IEC 60536 Class II
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Output
Current (A)
Input Current
Capacitive
Load
(µF, Max)
Model
Number
Efficiency
(%, Typ)
(mA Typ)
Voltage
(VDC)
115 VAC
230 VAC
169
Max.
3.00
2.66
2.00
1.60
1.00
1.00
0.80
Min.
0.00
Other outputs may be available
Contact the factory for details at:
sales@micropowerdirect.com
MPM-24MS-05xx
MPM-24MS-09xx
MPM-24MS-12xx
MPM-24MS-15xx
MPM-24MS-24xx
MPM-24MD-12xx
MPM-24MD-15xx
282
424
419
424
409
414
414
5.0
9.0
2,200
1,000
1,000
680
77
82
83
82
85
84
84
255
0.00
0.00
0.00
0.00
0.00
0.00
252
12.0
15.0
24.0
12.0
15.0
255
246
470
249
470
249
330
Notes:
Model Number
1. The specified maximum capacitive load is for each output.
2. Inrush current is given for a cold start at 25°C.
3. Ripple and noise is measured with a 0.1 µF/50V MLCC and a
1 µF/50V aluminum electrolytic connected between the +VOUT
and -VOUT pins for single output models or from each output to
common for dual output models.
4. Over voltage protection is provided by a zener diode clamp.
5. Output overload protection is provided by a “hiccup mode” circuit
with auto-recovery.A long-term overload could damage the unit.
6. The unit will shutdown at 90°C. It will recover automatically at
about 67 °C.
7. Output short circuit protection is provided by a “hiccup mode”
circuit. The unit recovers automatically when the fault condition
is removed.
8. Free air (natural) convection is about 20 LFM, it is not equal to
“still” air.
Derating Curve
9. Operation at no-load will not damage these units. However, they
may not meet all specifications.
10. It is recommended that an external slow blow fuse also be used
on the input for protection.
Chassis Mount & DIN Rail
All models of the MPM-24Mx series
are available in an encapsulated
package that can be mounted to a
chassis or cabinet and connected with
flying leads. To order the unit in this
package, add a “CM” to the end of the
product number.
This package can also be adapted for
use with a standard DIN rail by install-
ing a simple adapter kit. As illustrated
at right, this DIN rail kit consists of
a base plate, a DIN rail bracket and
the necessary hardware. For the
MPM-24Mx series the DIN rail kit is:
AC-DIN-01.
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
Mechanical Dimensions
www.micropowerdirect.com
Pin Connections
Pin
Single
AC Neutral
AC Line
-VOUT
Dual
AC Neutral
AC Line
-VOUT
1
2
4
5
No Pin
Common
+VOUT
6
+VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.5)
Mechanical Dimensions, Chassis Mount
For the “Chassis Mount” package, add suffix “CM”
to the model number (i.e. MPM-24MS-12CM)
Pin Connections
Pin
Single
AC Neutral
AC Line
NC
Dual
AC Neutral
AC Line
NC
1
2
3
4
-VOUT
NC
-VOUT
5
Common
+VOUT
NC
6
+VOUT
NC
7
NC = No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.5)
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
DIN Rail Mounting
All chassis mount MPM-24Mx models are easily
adapted for use with a standard 35 mm DIN rail by
installing a simple adapter kit.
The DIN rail kit consists of a base plate, a DIN rail
bracket and the necessary hardware. Mechanical dimen-
sions for an MPM-24Mx assembly with the DIN rail
option are shown below.
For the MPM-24Mx series the DIN rail kit is: AC-DIN-01.
Mechanical Dimensions, DIN Rail Mount
Pin Connections
Pin
Single
AC Neutral
AC Line
NC
Dual
AC Neutral
AC Line
NC
1
2
3
4
-VOUT
NC
-VOUT
5
Common
+VOUT
NC
6
+VOUT
NC
7
NC = No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.5)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号: