Series
MPM-08MB
Single & Dual Output, 8W
Miniature “Power Brick”
AC/DC Power Supplies
Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 8W Output Power
Input
Parameter
• Miniature Case
Conditions
Min.
90
120
47
Typ.
Max.
305
430
440
Units
VAC
VDC
Hz
• Wide 90-305 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Meets EN 55022 B
• Eight Standard Models
• >350 kHour MTBF
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
115 VAC
230 VAC
25.0
45.0
Inrush Current
A Pk
mA
Leakage Current
EMI
EMC
0.25
Meets CISPR Pub. 22/FCC Class B
Meets EN 55024
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation, See Note 2
Load Regulation, See Note 3
See Model Selection Guide
See Model Selection Guide
See Note 1
VIN = Min to Max
See Model Selection Guide
3.3, 5, 9 12, 15 Vout Models
2.0
%
%
0.2
100
150
100
150
200
150
Ripple (20 MHz), See Note 4
24 Vout Models
Dual Output Models
3.3, 5, 9 12, 15 Vout Models
24 Vout Models
mV P - P
Noise
mV P - P
mSec
Dual Output Models
115 VAC
10
75
Hold-Up Time
230 VAC
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, See Note 5
Overload Protection
General
Parameter
Isolation Voltage
0.02
120
%/°C
% of VO
Zener Diode Clamp
Continuous (Autorecovery)
115
150
% of IO
Conditions
Min.
Typ.
Max.
Units
VAC
M⍀
Input to Output 3,000
Isolation Resistance
EMI/RFI
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
100
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EMC Compliance
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
Environmental
Parameter
132
kHz
Conditions
Min.
-25
-40
-40
Typ.
+25
+25
Max.
+70
+70
Units
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
5.0/3.3 Vout Model
All Other Models
Operating Temperature Range, Ambient
Storage Temperature Range
Cooling
Humidity
+125
°C
Free Air Convection (See Derating Curves)
RH, Non-condensing 95
%
Physical
Case Size
Case Material
Weight
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
1.44 x 1.06 x 1.04 Inches (36.5 x 27.0 x 26.4 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
1.58 Oz (45g)
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
350
Typ.
Max.
Units
kHours
Vibration
Safety Approvals
Safety Class
10~55 Hz, 20G 1 min/1 Cycle. Period of 3 min each along X, Y &Z Axis
UL, cUL; File No. E245422
IEC 61140 Class II
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Current
Maximum Maximum
Load
Model
Number
Efficiency
(%, Typ)
Capacitive
Load
Output
Power
(W)
Current (A)
Regulation
(% Max)
Voltage
(VDC)
(µF)
115 VAC 230 VAC
Max. (A)
Min. (%)
MPM-08S-03MB
MPM-08S-05MB
MPM-08S-09MB
MPM-08S-12MB
MPM-08S-15MB
MPM-08S-24MB
0.190
0.190
0.190
0.190
0.190
0.190
0.120
0.120
0.120
0.120
0.120
0.120
3.3
5.0
9.0
12.0
15.0
24.0
5.0
3.3
12.0
5.0
2.000
1.600
0.888
0.666
0.533
0.335
1.600
0.310
0.666
0.100
0.0
0.0
0.0
0.0
0.0
3.0
2.0
0.5
0.5
0.5
0.5
0.5
5.0
0.5
5.0
26,000
6,000
2,300
1,050
440
6.60
8.00
8.00
8.00
8.00
8.00
72
78
79
79
80
81
0.0
180
25.0
25.0
25.0
25.0
4,500
3,800
260
MPM-08D-0503MB 0.200
MPM-08D-1205MB 0.200
Notes:
0.125
0.125
9.00
8.50
76
79
3,800
Mechanical Dimensions
1. The output voltage accuracy of the V2 output (pin 5) on dual outputs is 15% for the MPM-08D-
0503MB, and 10% for the MPM-08D-1205MB.
2. The line regulation of the dual output models is 2.0% for the V1 output (pin 4), and 3% for
the V2 output (pin 5).
3. Load regulation is measured from 10% load to 100% load.
4. Ripple and noise are measured at 20 Mhz bandwidth with a 0.1µF and a 47 µF capacitor con-
nected in parallel as close to the unit output terminals as possible.
5. Output short circuit protection is provided by a“hiccup mode”circuit.The unit recovers automatically when
the fault condition is removed.
6. Operation under no load conditions will not damage single output units.For dual output units,minimum load
requirements are given in the table above.
7. It is recommended that a fuse be used on the input of a power supply for protection. For the
MPM-08MB series, a 2A/250 VAC slow blow should be used.
Derating Curve - Single Output Models
Derating Curve - Dual Output Models
Notes:
Pin Connections
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
Pin
Single
AC-Line
AC-Neutral
Dual
1
2
3
4
5
-Vout
+Vout
NC
Common
Vout1
Vout2
NC = No Connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com