MPO60S05 [MPD]
MPO-60S Series;型号: | MPO60S05 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MPO-60S Series |
文件: | 总2页 (文件大小:343K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPO-60S
Single Output, 60W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 60W Output Power
• Universal 90-264 AC Input
• EN 60950 Approved (UL)
• Compact 2 x 4 In Package
• Eight Standard Models
• Meets EN 55022 B
Parameter
Conditions
Min.
90
127
47
Typ.
Max.
264
373
63
Units
VAC
VDC
Hz
Universal
Input Voltage Range
Input Frequency
Input Filter
Input Current
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
264 VAC
32.0
50.0
3.5
Inrush Current
A Pk
mA
• Meets EN 61000-4
Safety Ground Leakage Current
Output
• >200 kHour MTBF
Parameter
Conditions
See Model Selection Guide
See Note 1 1.0
Min.
Typ.
Max.
Units
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
%
%
%
%
Vin = Min to Max
Iout = 10% to 100%
See Note 2
0.5
1.0
1.0
115 VAC
230 VAC 100
8
Hold-Up Time
mSec
%/°C
Temperature Coefficient
Short Circuit Protection
Overload Protection
General
0.05
Continuous (Autorecovery)
See Note 3 150
%
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
M⍀
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Input to Output 3,000
500 VDC
1,000
4,700
Conducted
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
EMC Compliance
IEC/EN 61000-4-4
Surge
Fixed
IEC/EN 61000-4-5
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
66
kHz
Conditions
Min.
0
-20
Typ.
+25
Max.
+50
Units
°C
MicroPower Direct
292 Page Street
Suite D
Ambient
+85
°C
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Stoughton, MA 02072
USA
Humidity
%
Physical
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Size
Weight
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
5.21 Oz (0.150 kg)
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
Safety Standards
Vibration
UL 1950, EN 60950
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Current (A)
Max
Output
Max
Model
Number
Output
Power Capacitance
Efficiency
(%, Typ)
Current (A)
Voltage
(VDC)
115 VAC 230 VAC
Rated
% Min.
(W)
(µF)
MPO-60S-03
MPO-60S-05
MPO-60S-09
MPO-60S-12
MPO-60S-138
MPO-60S-15
MPO-60S-24
MPO-60S-48
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
3.3
5.0
9.0
12.0
13.8
15.0
24.0
48.0
8.00
8.00
6.67
5.00
4.35
4.00
2.50
1.25
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
26
8,800
8,800
6,670
5,000
3,600
3,600
2,500
770
74
78
82
84
83
85
86
88
40
60
60
60
60
60
60
Derating Curve
Other Models Are Available. Contact The Factory For Details
Notes:
1. Output voltage tolerance is measured at nominal input and 60% load.
2. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF
capacitors connected in parallel as close to the power supply terminals
as possible.
3. Overload protection is provided by an internal “hiccup” circuit.The unit
recovers automatically when the fault condition is removed.
4. These units will operate at no load without damage. For most appli-
cations however, MPD recommends that a minimum load always be
used. Contact the factory for more information.
5. Each unit includes an input fuse (250V/2A). Since this fuse is not field
replaceable, it is recommended that an external fuse of the same size
be used on the input of the power supply for protection.
Mechanical Dimensions
Connections
Input Connector (CN1):
• Molex 5273-03A or equivalent (one pin removed)
• Mating Housing: Molex 5195-03 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
2
Function
AC-Neutral
Removed
AC-Line
3
Safety Ground:
The mounting holes marked “Use metal standoffs” should be
connected to the system earth ground via metal spacers or
a cable. The input side mounting hole marked “FG” provides
the safety earth ground for the unit. This connection should
be locked to prevent possible loosening. Connecting the
output side mounting hole improves EMI.
Output Connector (CN2):
• Molex 5273-04A or equivalent
• Mating Housing: Molex 5195-04 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
Function
+VOUT
2
+VOUT
3
-VOUT
4
-VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com