MSK114VRH [MSK]
Operational Amplifier, 2 Func, 1100uV Offset-Max, CDFP14, CERAMIC, DFP-14;型号: | MSK114VRH |
厂家: | M.S. KENNEDY CORPORATION |
描述: | Operational Amplifier, 2 Func, 1100uV Offset-Max, CDFP14, CERAMIC, DFP-14 放大器 CD |
文件: | 总6页 (文件大小:570K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MIL-PRF-3 8 5 3 4 CERTIFIED
RAD HARD
QUAD PRECISION
OP-AMP
114RH
M.S.KENNEDY CORP.
4707 Dey Road Liverpool, N.Y. 13088
(315) 701-6751
FEATURES:
Manufactured using
Space Qualified RH1013 Die
MIL-PRF-38535 Class V Processing & Screening
Total Dose Tested to TBD Krads(Si) (Method 1019.7 Condition A)
Single Supply Operation
Low Offset Voltage
Low Drift
Available in Straight or Gull Wing Lead Form
Contact MSK for MIL-PRF-38535 Qualification and Radiation Status
DESCRIPTION:
The MSK 114RH is a radiation hardened quad operational amplifier for use in space and severe military applications. This
device offers low offset voltage, low drift, low offset current and high gain combined with a space efficient 14 pin surface
mount flat pack. The MSK 114RH is an ideal solution when multiple precision amplifiers are required and board space is at
a premium. The MSK 114RH 14 pin ceramic flat pack is offered with straight leads or gull wing for surface mount applica-
tions.
EQUIVALENT SCHEMATIC
PIN-OUT INFORMATION
TYPICAL APPLICATIONS
14 OUT D
13 -IN D
12 + IN D
11 -VCC
10 + IN C
1 OUT A
2 -IN A
3 + IN A
4 + VCC
5 + IN B
6 -IN B
Battery Powered Precision Instrumentation
Multiple Limit Threshold Detection
Active Filters
Multiple Gain Blocks
Instrumentation Amplifiers
9
8
-IN C
OUT C
7 OUT B
1
PRELIMINARY Rev. - 10/09
7
ABSOLUTE MAXIMUM RATINGS
-65° C to + 150° C
Storage Temperature Range
Lead Temperature Range
(10 Seconds)
± VCC
VIN
± 22V
± 30V
Supply Voltage
Differential Input Voltage
Input Voltage
TST
TLD
300° C
150° C
Equal to Positive Supply Voltage
5V Below Negative Supply Voltage
Junction Temperature
TJ
Case Operating Temperature Range
MSK 114RH
Output Short Circuit Duration
Indefinite
TC
-40° C to+ 85° C
-55° C to + 125° C
MSK 114VRH
ELECTRICAL SPECIFICATIONS
NOTES:
1
2
3
4
5
Unless otherw ise specified; ± VCC= ± 15VDC, VCM= 0V.
Devices shall be capable of meeting the parameter, but need to be tested. Typical parameters are for reference only.
Industrial grade devices shall be tested to subgroup 1 unless otherwise specified.
Military grade devices (' V' Suffix) shall be 100% tested to subgroups 1,2,3 and 4.
Subgroup 1, 4
Subgroup 2, 5
Subgroup 3, 6
TA= TC= + 25° C
TA= TC= + 125° C
TA= TC= -55° C
6
7
8
Refer to SMD TBD for electrical parameters for devices purchased as such.
Continuous operation at or above absolute maximum ratings may adversely effect the device performance and/or life cycle.
Pre and Post irradiation limits at 25° C, to TBD Krads TID, are identical unless otherw ise specified.
PRELIMINARY Rev. - 10/09
2
APPLICATION NOTES
TOTAL DOSE RADIATION TEST
PERFORMANCE
SINGLE SUPPLY OPERATION
The MSK 114RH may be used in single supply applications where
the negative supply is 0 volts. The device incorporates unique phase
reversal protection circuitry to avoid the most common problems
occurring during single supply operation. The phase reversal protec-
tion circuitry, however does not function when one specific ampli-
fier of the other three is driven hard into negative saturation at the
output. Phase reversal protection does not work under the following
conditions: Amplifier A and D when the opposite output is negative
saturation. Amplifiers B and C outputs have no effect. Amplifier B
or C when the opposite output is in negative saturation. Amplifiers
A and D outputs have no effect. The MSK 114RH all-NPN output
stage maintains it' s low output resistance and high gain character-
istics until the output is saturated. In dual supply applications, the
output stage w ill remain crossover distoration-free. The minimum
single supply voltage for proper operation of the MSK 114RH is + 5
Volts.
Radiation performance curves for TID testing w ill be generated for
all radiation testing performed by MS Kennedy. These curves show
performance trends throughout the TID test process and will be lo-
cated in the MSK 114RH radiation test report. The complete radia-
tion test report will be available in the RAD HARD PRODUCTS sec-
tion on the MSK website.
ADDITIONAL APPLICATION INFORMATION
For additional applications information, please reference Linear Tech-
nology Corporation' s® LT1013/1014 and RH1014 data sheets.
FIGURE 1
FIGURE 2
3
PRELIMINARY Rev. - 10/09
TYPICAL PERFORMANCE CURVES
PRELIMINARY Rev. - 10/09
4
MECHANICAL SPECIFICATIONS
ESD TRIANGLE INDICATES PIN 1
WEIGHT= TBD
ORDERING INFORMATION
MSK114 V RH
LEAD CONFIGURATIONS
BLANK= STRAIGHT
RADIATION HARDENED
SCREENING
BLANK= INDUSTRIAL
V= MIL-PRF-38535 CLASS V
GENERAL PART NUMBER
The above example is a Class V device with straight leads.
5
PRELIMINARY Rev. - 10/09
ESD TRIANGLE INDICATES PIN 1
WEIGHT= TBD
ORDERING INFORMATION
MSK114 V RH G
LEAD CONFIGURATIONS
G= GULL WING
RADIATION HARDENED
SCREENING
BLANK= INDUSTRIAL
V= MIL-PRF-38535 CLASS V
GENERAL PART NUMBER
The above example is a Class V device with gull wing leads.
M.S. Kennedy Corp.
4707 Dey Road, Liverpool, New York 13088
Phone (315) 701-6751
FAX (315) 701-6752
w w w .mskennedy.com
The information contained herein is believed to be accurate at the time of printing. MSK reserves the right to make
changes to its products or specifications without notice, however, and assumes no liability for the use of its products.
Please visit our website for the most recent revision of this datasheet.
Contact MSK for MIL-PRF-38535 Class V and radiation status.
6
PRELIMINARY Rev. - 10/09
©2020 ICPDF网 联系我们和版权申明