10BXC-2E3A-KK/Q 概述
High-density Signal Conditioners 10-RACK
10BXC-2E3A-KK/Q 数据手册
通过下载10BXC-2E3A-KK/Q数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: 10BXC
High-density Signal Conditioners 10-RACK
[3] POWER SUPPLY UNIT
AC Power
K: 85 – 132 V AC; single power source
STANDARD RACK
Functions & Features
(Operational voltage range 85 – 132 V, 47 – 63 Hz)
K2: 85 – 132 V AC; dual-redundant power supply
(Operational voltage range 85 – 132 V, 47 – 63 Hz)
KK: 85 – 132 V AC; two independent power sources
(Operational voltage range 85 – 132 V, 47 – 63 Hz)
L: 170 – 264 V AC; single power source
• Standard 19" rack for 10-RACK signal conditioners
• Line power supplied via the rear rack bus
• Dual-redundant power supply or two independent power
sources selectable with AC power supply
• Supply pressure at manifold plug
(Operational voltage range 170 – 264 V, 47 – 63 Hz)
L2: 170 – 264 V AC; dual-redundant power supply
(Operational voltage range 170 – 264 V, 47 - 63 Hz)
DC Power
• Direct interface to various DCS with the rack connector
R: 24 V DC; no power supply unit
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
AC/DC Power
KR: 85 – 132 V AC / 24 V DC; two independent power sources
(85 – 132 V, 47 – 63 Hz or 24V ±10 %, ripple 10 %p-p max.)
(Redundant or independent power sources are
recommended for long time use without interruption.)
MODEL: 10BXC-[1][2]-[3][4]
[4] OPTIONS
blank: none
ORDERING INFORMATION
• Code number: 10BXC-[1][2]-[3][4]
Specify a code from below for each [1] through [4].
(e.g. 10BXC-12-K2/Q)
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
Power supply and signal conditioner side of the main PWB are not coated.
/C01: Silicone coating
• Specify the specification for option code /Q
(e.g. /C01)
/C02: Polyurethane coating
[1] FUNCTION
1: Power distribution
/C03: Rubber coating
2: Power distribution & pressure supply
RELATED PRODUCTS
• Blank filler plate (model: P-101)
[2] CONNECTOR
• Connector terminal block (model: CNT)
• Special cable with 40-pin connector (model: FCN)
0: None
1: Fujitsu FCN type I/O connector
2: Yokogawa DCS connector (MAC2 dual redundant system use)
3: Nippon Shokubai DCS connector
4: Azbil DCS AI connector
GENERAL SPECIFICATIONS
Construction: Metal plates assembly
5: Azbil DCS AO connector
Capacity: 16 positions
6: Azbil DCS AI connector (ELCO connector)
7: Azbil DCS AO connector (ELCO connector)
8: Yokogawa DCS connector (VMx/PM1 dual redundant system use)
E3: Toshiba DCS SAIN1 card use
Connection
Power input: M4 screw terminals (torque 0.8 N·m)
Power alarm: M4 screw terminals (torque 0.8 N·m)
Pneumatic: Rc 3/8" female (torque ≤ 12 N·m)
Screw terminal: Nickel-plated brass
(Panasonic AXM220001 used)
(DISCONTINUED; replace with code "E3A".)
E3A: Toshiba DCS SAIN1 card supported
(Omron XG4A-2031 used)
Manifold: Aluminium alloy
Isolation: I/O connector to alarm output to power to FG
Power alarm output: N.C. contact turns off at power failure
or failure of power units. Supplied only with dual-redundant
power supply or two independent power sources
H1: Hitachi DCS connector
H2: Hitachi DCS EX-CDL cable connector
M-System guarantees the connecting section.
http://www.m-system.co.jp/
10BXC SPECIFICATIONS
ES-0893 Rev.12 Page 1/7
MODEL: 10BXC
Power RUN LED: Light turns on in normal conditions
(supplied only with dual-redundant power supply or two
independent power sources)
OUTPUT SPECIFICATIONS
■ Alarm Output
(Supplied only with dual-redundant power supply or two
independent power sources)
Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC or 125 V DC
Maximum switching power: 750 VA or 60 W
Minimum load: 5 V DC @ 100 mA
Mechanical life: 5 × 10 cycles (rate 180 cycles/min.)
6
INSTALLATION
Supply pressure: Refer to the data sheet for I/P transducers
(power distribution & pressure supply type)
Power consumption
•AC: 130 VA min.
•DC: 2.5 A min.
Operating temperature: -5 to +55°C (23 to 131°F) 0 to 50°C
(32 to 122°F) for AC power
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: JIS or EIA standard rack
Weight
Single power supply w/o power units:
3.0 kg (6.6 lb) with DC power type
3.5 kg (7.7 lb) with AC power type
Dual-redundant or two independent power sources:
3.5 kg (7.7 lb) with AC/DC power type
4.0 kg (8.8 lb) with AC/AC power type
Add 2 kg (4.4 lb) for air manifold type.
PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 500 V AC @ 1 minute (I/O connector to
alarm output to power)
1500 V AC @ 1 minute (power to FG)
500 V AC @ 1 minute (I/O connector or alarm output to FG,
1000 AC with power input code R)
Maximum supply pressure: 196 kPa
(2 kgf/cm , 1.96 bar, 28 psig)
2
http://www.m-system.co.jp/
10BXC SPECIFICATIONS
ES-0893 Rev.12 Page 2/7
MODEL: 10BXC
MOUNTING REQUIREMENTS
465 (18.31)
450 (17.72)
4–M5 SCREW
ANGLE BRACKET
Observe an appropriate wiring space below.
100 (3.94) for JIS standard
*
CONNECTION DIAGRAM
Remark 1: No.s of connectors may change with model suffix code.
Remark 2: Supply pressure connection provided only for 10BXC-2.
■ Single Power Source,
Dual-redundant Power Supply
■ Two Independent Power Sources,
DC/AC Power Supply
■ Two Independent Power Sources,
AC/AC Power Supply
U(+)
V(–)
+
–
CN1
CN2
CN3
CN4
1
2
3
4
5
6
CN1
CN2
CN3
CN4
1
2
3
4
5
6
4
5
CN1
CN2
CN3
CN4
1
2
3
4
5
6
4
5
4
5
POWER
DC POWER
FG
FG
FG
PWR1
PWR1
PWR1
*
ALM. OUTPUT
PWR2
ALM. OUTPUT
ALM. OUTPUT
DC POWER
ALM. OUTPUT
ALM. OUTPUT
PWR2
ALM. OUTPUT
*
COM.
COM.
COM.
U
U
PWR1
AC POWER
V
PWR1
PWR2
AC POWER
V
U
SUPPLY
PRESSURE
SUPPLY
PRESSURE
SUPPLY
PRESSURE
AC POWER
V
*Alarm output not provided for single power supply.
http://www.m-system.co.jp/
10BXC SPECIFICATIONS
ES-0893 Rev.12 Page 3/7
MODEL: 10BXC
DIMENSIONS unit: mm (inch)
AIR MANIFOLD ***
435 (17.13)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
3–M4 ALARM **
5–M4 POWER
OUTPUT TERMINAL
UNIT TERMINAL
8.2 (.32)
8.5 (.33)
SUPPLY CONNECTION
Rc 3/8” ***
POWER 1 LED **
POWER UNIT
*
POWER 2 LED **
PWR1
1 2 3 4 5
PWR2
1 2 3 4 5
CONNECTORS
4
5 6
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
1
2
3
3–M4 POWER
TERMINAL
465 (18.31)
480 (18.90)
*
PWR1 only for AC single power supply.
** Alarm output provided only for dual-redundant power supply or two independent power sources.
***Pneumatic connection provided only for model 10BXC-2.
http://www.m-system.co.jp/
10BXC SPECIFICATIONS
ES-0893 Rev.12 Page 4/7
MODEL: 10BXC
I/O CONNECTOR PIN ASSIGNMENT
Fujitsu FCN type I/O connector
•
•Nippon Shokubai DCS connector
Connector Pin Assignment
Location
CN1:
Fujitsu FCN-364P040-AU
CN1:
HIF3F-34PA-2.54DSA
The input or output 2 (output 1 with single output
type) is connected to the connector.
The input or output 2 (output 1 with single output
type)is connected to the connector.
RACK LOCATION NO.
7
PIN NO.
ASSIGNMENT
PIN NO.
ASSIGNMENT
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A10
A11
A12
A13
A14
A15
A16
ch. 1 +
ch. 2 +
ch. 3 +
ch. 4 +
ch. 5 +
ch. 6 +
ch. 7 +
ch. 8 +
ch. 9 +
ch.10 +
ch.11 +
ch.12 +
ch.13 +
ch.14 +
ch.15 +
ch.16 +
B 1
B 2
B 3
B 4
B 5
B 6
B 7
B 8
B 9
B10
B11
B12
B13
B14
B15
B16
ch. 1 –
ch. 2 –
ch. 3 –
ch. 4 –
ch. 5 –
ch. 6 –
ch. 7 –
ch. 8 –
ch. 9 –
ch.10 –
ch.11 –
ch.12 –
ch.13 –
ch.14 –
ch.15 –
ch.16 –
6
7
8
9
10 11 12 13 14 15 16
NIPPON SHOKUBAI DCS LOCATION NO.
•Connector Pin Assignment
PIN NO.
ASSIGNMENT
PIN NO.
ASSIGNMENT
1
2
No Connection
No Connection
ch.16 –
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
ch. 8 –
ch. 8 +
ch. 7 –
ch. 7 +
ch. 6 –
ch. 6 +
ch. 5 –
ch. 5 +
ch. 4 –
ch. 4 +
ch. 3 –
ch. 3 +
ch. 2 –
ch. 2 +
ch. 1 –
ch. 1 +
3
4
ch.16 +
ch.15 –
ch.15 +
ch.14 –
5
6
7
8
9
ch.14 +
ch.13 –
ch.13 +
ch.12 –
10
11
12
13
14
15
16
17
18
A17 – A20, B17 – B20: Unused
ch.12 +
ch.11 –
ch.11 +
Yokogawa DCS connector
•
ch.10 –
Location
ch.10 +
ch. 9 –
ch. 9 +
I/O connector: PS-40PE-D4T1-PN1
CN1:
CN2:
CN3:
MAC2 / PAC card use*
MAC2 / PAC card use* for redundancy
VMx / PM1 card use**
Azbil DCS AI connector
•
The input or output 2 (output 1 with single output
type) is connected to the connector.
I/O cable: J-RSL / J-RSK
J-RRL / J-RRK
RACK LOCATION NO.
7
Location
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
Input connector: 57GE-40500-751
6
7
8
9
10 11 12 13 14 15 16
CN1, CN2: J-HAM50 / J-HMM00 module use
The output 2 (output 1 with single output type)
is connected to the connector. The CN1 and CN2
are connected in parallel.
VM1/PM1/VM4 CARD INPUT or OUTPUT
CN3
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
VM2 CARD INPUT NO.
CN3
VM2 CARD OUTPUT NO.
CN3
RACK LOCATION NO.
7
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
1
i
1
o
2
i
2
o
3
i
3
o
4
i
4
o
5
i
5
o
6
i
6
o
7
i
7
o
8
i
8
o
6
7
8
9
10 11 12 13 14 15 16
MAC2/PAC CARD I/O (i = input, o = output)
CN1, CN2
AZBIL DCS AI CONNECTOR
*MAC2 card (uses KS1 cable)
I/O card used for control I/O. Composed of 8 inputs
and 8 outputs. Input and output are paired. (Replace
with pulse inputs for PAC card.)
**VMx / PM1 card (uses KS2 cable)
VM1: analog input 16 points
VM2: analog input 8 points / analog output 8 points
VM4: analog output 16 points
PM1: pulse input 16 points
http://www.m-system.co.jp/
10BXC SPECIFICATIONS
ES-0893 Rev.12 Page 5/7
MODEL: 10BXC
•
Yokogawa DCS connector
Location
I/O connector: PS-40PE-D4T1-PN1
Azbil DCS AO connector
•
I/O cable: J-RSL / J-RSK
J-RRL / J-RRK
CN1:
CN2:
VMx / PM1 card use (uses KS2 cable)
VMx / PM1 card use for redundancy
Location
Output connector: 57GE-40500-751
CN1, CN2: J-AOM10 module use
The input is connected to the connector. The CN1 and
CN2 are connected in parallel.
Install the Extender Module (model: 10BW) to unused
channels in order to close the circuit.
The input or output 2 (output 1 with single output type)
is connected to the connector.
RACK LOCATION NO.
7
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
6
7
8
9
10 11 12 13 14 15 16
VM1/PM1/VM4 CARD INPUT or OUTPUT
CN1, CN2
RACK LOCATION NO.
7
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
6
7
8
9
10 11 12 13 14 15 16
VM2 CARD INPUT NO.
CN1, CN2
VM2 CARD OUTPUT NO.
CN1, CN2
AZBIL DCS AO CONNECTOR
•Connector Pin Assignment
Azbil DCS AI connector
•
PIN NO.
ASSIGNMENT
PIN NO.
ASSIGNMENT
I/O cable: J-SSL / J-SSK
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
ch. 1 +
ch. 1 –
ch. 2 +
ch. 2 –
ch. 3 +
ch. 3 –
ch. 4 +
ch. 4 –
ch. 5 +
ch. 5 –
ch. 6 +
ch. 6 –
ch. 7 +
ch. 7 –
ch. 8 +
ch. 8 –
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
ch. 9 +
ch. 9 –
ch.10 +
ch.10 –
ch.11 +
ch.11 –
ch.12 +
ch.12 –
ch.13 +
ch.13 –
ch.14 +
ch.14 –
ch.15 +
ch.15 –
ch.16 +
ch.16 –
J-SRL / J-SRK
Location
Input connector: 00-8016-056-296-707V
CN1, CN2: J-HAM50 / J-HMM00 module use
The output 2 (output 1 with single output type)
is connected to the connector. The CN1 and CN2
are connected in parallel.
RACK LOCATION NO.
7
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
6
7
8
9
10 11 12 13 14 15 16
AZBIL DCS AI CONNECTOR
Azbil DCS AO connector
•
I/O cable: J-SSL / J-SSK
1 – 8: Unused
VM1: analog input 16 points
J-SRL / J-SRK
VM2: analog input 8 points / analog output 8 points
VM4: analog output 16 points
Location
Output connector: 00-8016-056-296-707V
CN1, CN2: J-AOM10 module use
The input is connected to the connector. The CN1 and
CN2 are connected in parallel.
PM1: pulse input 16 points
Toshiba DCS SAIN1 card use
•
Install the Extender Module (model: 10BW) to unused
channels in order to close the circuit.
Location
Input connector: OmronXG4A-2031
CN1:
CN2:
CN3:
CN4:
SAIN1 (ch.1 – ch.8)
RACK LOCATION NO.
7
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
SAIN1 (ch.1 – ch.8) for redundancy
SAIN1 (ch.9 – ch.16)
6
7
8
9
10 11 12 13 14 15 16
AZBIL DCS AO CONNECTOR
SAIN1 (ch.9 – ch.16) for redundancy
The output 2 (output 1 with single output type)
is connected to the connector.
RACK LOCATION NO.
7
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
6
7
8
1
2
3
4
5
CN3, CN4
6
7
8
CN1, CN2
SAIN1 INPUT POINT NO.
Toshiba DCS SAMP1 uses Panasonic AXM220001.
As connector is discontinued, Omron XG4A-2031 is
used as an alternative. (Replace cable side.)
http://www.m-system.co.jp/
10BXC SPECIFICATIONS
ES-0893 Rev.12 Page 6/7
MODEL: 10BXC
•Hitachi DCS connector
Location
CN1, CN2: DN20B-36S
The input or output 2 (Output 1 with single output
type) is connected to the connector.
RACK LOCATION NO.
7
1
1
2
2
3
3
4
4
5
5
6
8
9
10 11 12 13 14 15 16
6
7
8
9
10 11 12 13 14 15 16
HITACHI DCS CONNECTOR
Connector Pin Assignment
PIN NO.
ASSIGNMENT
PIN NO.
ASSIGNMENT
1
19
2
ch. 1 +
ch. 1 –
ch. 2 +
ch. 2 –
ch. 3 +
ch. 3 –
ch. 4 +
ch. 4 –
ch. 5 +
ch. 5 –
ch. 6 +
ch. 6 –
ch. 7 +
ch. 7 –
ch. 8 +
ch. 8 –
9
ch. 9 +
ch. 9 –
ch.10 +
ch.10 –
ch.11 +
ch.11 –
ch.12 +
ch.12 –
ch.13 +
ch.13 –
ch.14 +
ch.14 –
ch.15 +
ch.15 –
ch.16 +
ch.16 –
27
10
28
11
29
12
30
13
31
14
32
15
33
16
34
20
3
21
4
22
5
23
6
24
7
25
8
26
•Hitachi DCS EX-CDL cable connector
Location
CN1: 57GE-40360-751 (D7A)
The input or output 2 (output 1 with single output
type) is connected to the connector.
PIN NO.
ASSIGNMENT
PIN NO.
ASSIGNMENT
1
19
2
20
3
ch. 1 +
ch. 1 –
ch. 2 +
ch. 2 –
ch. 3 +
ch. 3 –
ch. 4 +
ch. 4 –
ch. 5 +
ch. 5 –
ch. 6 +
ch. 6 –
ch. 7 +
ch. 7 –
ch. 8 +
ch. 8 –
9
ch. 9 +
ch. 9 –
ch.10 +
ch.10 –
ch.11 +
ch.11 –
ch.12 +
ch.12 –
ch.13 +
ch.13 –
ch.14 +
ch.14 –
ch.15 +
ch.15 –
ch.16 +
ch.16 –
27
10
28
11
29
12
30
13
31
14
32
15
33
16
34
21
4
22
5
23
6
24
7
25
8
26
Specifications are subject to change without notice.
http://www.m-system.co.jp/
10BXC SPECIFICATIONS
ES-0893 Rev.12 Page 7/7
10BXC-2E3A-KK/Q 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
10BXC-2E3A-KR | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2E3A-KR/Q | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2E3A-L | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2E3A-L/Q | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2E3A-L2 | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2E3A-L2/Q | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2E3A-R | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2E3A-R/Q | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 | |
10BXC-2H1 | MSYSTEM | STANDARD RACK | 获取价格 | |
10BXC-2H1-K | MSYSTEM | High-density Signal Conditioners 10-RACK | 获取价格 |
10BXC-2E3A-KK/Q 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8