10YS-HC6-R [MSYSTEM]

High-density Signal Conditioners 10-RACK;
10YS-HC6-R
型号: 10YS-HC6-R
厂家: M-SYSTEM    M-SYSTEM
描述:

High-density Signal Conditioners 10-RACK

文件: 总3页 (文件大小:91K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: 10YS  
High-density Signal Conditioners 10-RACK  
[2] OUTPUT 1  
Current  
A: 4 – 20 mA DC (Load resistance 600 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)  
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 600 Ω max.)  
E: 0 – 16 mA DC (Load resistance 750 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)  
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)  
Voltage  
OUTPUT ISOLATOR  
Functions & Features  
• Converting a DC input into two isolated standard process  
signal  
• Input from the Standard Rack connector can be monitored  
at the front terminals  
Typical Applications  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
• Isolation between control room and field instrumentation  
[3] OUTPUT 2  
0: None  
Voltage  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
POWER INPUT  
DC Power  
R: 24 V DC  
MODEL: 10YS–[1][2][3]–R[4]  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
ORDERING INFORMATION  
• Code number: 10YS-[1][2][3]-R[4]  
Specify a code from below for each [1] through [4].  
(e.g. 10YS-1A6-R/Q)  
[4] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
• Special input range (For code 0)  
• Specify the specification for option code /Q  
(e.g. /C01)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
[1] INPUT  
Current  
/C03: Rubber coating  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
Voltage  
GENERAL SPECIFICATIONS  
Construction: Rack-mounted; terminal access via screw  
terminals at the front and via card-edge connector at the  
rear; terminal cover provided  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
Connection  
Input: Card-edge connector  
Output, input monitor: M3.5 screw terminals (torque 0.8  
N·m)  
Power input: Supplied from card-edge connector  
Screw terminal: Nickel-plated steel  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
http://www.m-system.co.jp/  
10YS SPECIFICATIONS  
ES-0871 Rev.7 Page 1/3  
MODEL: 10YS  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
INPUT SPECIFICATIONS  
DC Current: Input resistor incorporated  
DC Voltage: 0 – 300 V DC  
Minimum span: 3 mV  
Offset: Max. 1.5 times span  
Input Resistance  
Span 3 – 10 mV : ≥ 10 kΩ  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Span ≥ 1 V : ≥ 1 MΩ  
OUTPUT SPECIFICATIONS  
With the input voltage code 3, 4, 5, 6 and current, the  
output goes below 0 % when the input is open.  
INSTALLATION  
Current consumption: Approx. 25 mA with voltage output 1  
Approx. 45 mA with current output 1  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Standard Rack 10BXx  
Weight: 200 g (0.44 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 500 V AC @ 1 minute  
(input to output 1 to output 2 to power)  
1500 V AC @ 1 minute (input or output or power to ground)  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
7–M3.5 SCREW  
8 (.31)  
2–4.3 (.17) dia.  
MTG HOLE  
TERMINAL COVER  
1
5
2
6
3
7
8
3 (.12)  
25 (.98)  
51 (2.01)  
130 (5.12)  
http://www.m-system.co.jp/  
10YS SPECIFICATIONS  
ES-0871 Rev.7 Page 2/3  
MODEL: 10YS  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Z
S
Isolation  
Low Drift  
Amplifier  
Voltage/  
Duty Cycle  
Output  
Driver  
+
1
2
3
7
8
+
*
INPUT MONITOR  
OUTPUT 1  
OUTPUT 2  
Z
S
Output  
Driver  
5
6
+
INPUT  
POWER  
*Input shunt resistor incorporated for current input.  
Remark 1) The section enclosed by broken line is only for 2nd output channel.  
Specifications are subject to change without notice.  
http://www.m-system.co.jp/  
10YS SPECIFICATIONS  
ES-0871 Rev.7 Page 3/3  

相关型号:

10YS-HD0-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YS-HD6-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YS-HE0-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YS-HE6-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YS-HF0-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YS-HF6-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YS-HG0-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YS-HG6-R

High-density Signal Conditioners 10-RACK
MSYSTEM

10YXA1000020CC16X35.5

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 10V, 10000uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
RUBYCON

10YXA1000020CE16X35.5

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 10V, 10000uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
RUBYCON

10YXA10000M16X355

MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS
RUBYCON

10YXA10000MCA16X35.5

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 10V, 10000uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
RUBYCON