17PA-11M6-R [MSYSTEM]
Rack-mounted Power Transducers 17-RACK;型号: | 17PA-11M6-R |
厂家: | M-SYSTEM |
描述: | Rack-mounted Power Transducers 17-RACK |
文件: | 总3页 (文件大小:98K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: 17PA
Rack-mounted Power Transducers 17-RACK
AUXILIARY POWER SUPPLY
DC Power
R: 24 V DC
PHASE ANGLE TRANSDUCER
Functions & Features
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
• Providing a DC output signal in proportion to phase angle
• DC output containing little ripple is ideal for computer
input
GENERAL SPECIFICATIONS
Construction: Rack-mounted; terminal access via screw
terminals on the front and connector on the rear; terminal
cover provided
Typical Applications
• Centralized monitoring and control of power management
system in a manufacturing facility or building
• Measuring phase angle for a motor
Connection
Input: M3.5 screw terminals (torque 0.8 N·m)
Output: Connector
Auxiliary power: Supplied from connector
Screw terminal: Nickel-plated steel
Isolation: Voltage input to current input to output to
auxiliary power
Computation: Phase angle detection
Overrange output: Approx. -10 to +120 %
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
INPUT SPECIFICATIONS
■INPUT
MODEL: 17PA–1[1][2]6–R
Frequency: 50 or 60 Hz
•Voltage Input
ORDERING INFORMATION
• Code number: 17PA-1[1][2]6-R
Specify a code from below for each [1] and [2].
(e.g. 17PA-11P6-R)
Input burden: 0.5 VA
Operational range: 85 – 120 % of rating
Overload capacity: 150 % of rating for 10 sec., 120 %
continuous
•Current Input
Input burden: 0.1 VA (input 1 A)
0.5 VA (input 5 A)
CONFIGURATION
1: 3-phase / 3-wire
Operational range: 10 – 120 % of rating
Overload capacity: 1000 % of rating for 3 sec., 200 % for 10
sec., 120 % continuous
[1] INPUT (balanced load)
1: 110 V / 5 A AC
■ Input range:
2: 110 V / 1 A AC
Lag 60° – 0 – lead 60°
3: 220 V / 1 A AC
Lead 60° – 0 – lag 60°
4: 220 V / 5 A AC
[2] OUTPUT SIGNAL POLARITY
P: Negative in lag, positive in lead
M: Negative in lead, positive in lag
OUTPUT
Voltage
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
http://www.m-system.co.jp/
17PA SPECIFICATIONS
ES-2969 Rev.0 Page 1/3
MODEL: 17PA
OUTPUT SPECIFICATIONS
■ OPERATION DIAGRAM (example)
• Negative in lag, positive in lead
OUT
5V
3
1
60°
(Lag)
0
60°
(Lead)
• Negative in lead, positive in lag
OUT
5V
3
1
60°
(Lag)
0
60°
(Lead)
Remark: When there is no input voltage or 5% or less of
rated input current , the output may become unstable (hunting).
INSTALLATION
Auxiliary power supply
Current consumption: Approx. 40 mA
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 40 to 85 % RH (non-condensing)
Mounting: Standard Rack 17BXE
Weight: 200 g (0.44 lb)
PERFORMANCE in percentage of span
Accuracy: ±2 % with balanced load
(at 23°C ±10°C or 73.4°F ±18°F, 45 – 65 Hz)
Response time: ≤ 2 sec. (0 – 100 % ±1 %)
Ripple: 1 %p-p max.
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 500 V AC @ 1 minute (output to
auxiliary power)
2000 V AC @ 1 minute (voltage input to current input to
output or auxiliary power)
1500 V AC @1 minute (voltage input or current input or
output or auxiliary power to ground)
http://www.m-system.co.jp/
17PA SPECIFICATIONS
ES-2969 Rev.0 Page 2/3
MODEL: 17PA
CONNECTION DIAGRAM
3-PHASE/3-WIRE
SOURCE
1
2
3
VT
FUSE
FUSE
V
U
v
P2
P3
6
5
u
OUTPUT
K
AUXILIARY
POWER
k
l
1S
1L
1
2
L
LOAD
DIMENSIONS unit: mm (inch)
2–M3
SCREW
8–M3.5
7 (.28)
SCREW
7 (.28)
24 (.94)
32 (1.26)
78 (3.07)
TERMINAL ASSIGNMENTS
7
8
5
6
1
2
3
4
Specifications are subject to change without notice.
http://www.m-system.co.jp/
17PA SPECIFICATIONS
ES-2969 Rev.0 Page 3/3
相关型号:
©2020 ICPDF网 联系我们和版权申明