40DT-T1-L3 [MSYSTEM]

Digital Panel Meters 40 Series;
40DT-T1-L3
型号: 40DT-T1-L3
厂家: M-SYSTEM    M-SYSTEM
描述:

Digital Panel Meters 40 Series

文件: 总6页 (文件大小:201K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: 40DT  
Digital Panel Meters 40 Series  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
Moving parts and indicators are not coated.  
/C01: Silicone coating  
THERMOCOUPLE INPUT DIGITAL PANEL METER  
(4 digits, process meter)  
/C02: Polyurethane coating  
Functions & Features  
/C03: Rubber coating  
• 4 digit (±9999) panel meter  
EX-FACTORY SETTING  
• HOLD functions  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-9535)  
• High visible, 0.8" (20.3mm) high and bright LED  
96 (3.78)  
GENERAL SPECIFICATIONS  
Construction: Panel flush mounting  
48  
(1.89)  
Connection: M3 screw terminals (torque 0.6 N·m)  
Solderless terminal: Refer to the drawing at the end of the  
section.  
96 (3.78)  
Recommended manufacturer: Japan Solderless Terminal  
MFG.Co.Ltd, Nichifu Co.,ltd  
mm (inch)  
Applicable wire size: 0.25 to 1.65 mm  
2
(AWG 22 to 16)  
Screw terminal: Nickel-plated steel  
MODEL: 40DT–T1–[1][2]  
Housing material: Flame-resistant resin (gray)  
Isolation: Input to power  
Cold junction compensation: CJC sensor attached to the  
input terminals  
ORDERING INFORMATION  
• Code number: 40DT–T1–[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. 40DT-T1-R/Q)  
A/D conversion: Σ – Δ  
Sampling rate: 10 times/sec. (100 msec.)  
Averaging: None or moving average  
Setting: (Front button)  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
• Input type  
• Temperature unit  
INPUT  
T1:  
• Moving average  
• Brightness  
K (CA) (Usable range -150 to +1370°C, -238 to +2498°F)  
J (IC) (Usable range -180 to +1000°C, -292 to +1832°F)  
T (CC) (Usable range -170 to +400°C, -274 to +752°F)  
R (Usable range 380 to 1760°C, 716 to 3200°F)  
• Others  
■Recommended solderless terminal  
3.3 (.13) max  
[1] POWER INPUT  
AC Power  
mm (inch)  
K3: 100 – 120V AC  
(Operational voltage range 85 - 132 V, 47 - 66 Hz)  
L3: 200 – 240V AC  
DISPLAY  
(Operational voltage range 170 - 264 V, 47 - 66 Hz)  
DC Power  
Display: 4 digits of 20.3 mm (0.8 inch) height, 7-segment,  
red LED  
R: 24 V DC  
Display range: -9999 to 9999  
(Operational voltage range 24 V ±20 %, ripple 10 %p-p max.)  
Minimum display/setting scale: 1°C or 1°F  
Zero indication: Higher-digit zeros are suppressed.  
Over-range indication:  
[2] OPTIONS  
blank: none  
'S.ERR' blinks surpassing the permissible range.  
'B.ERR' blinks at burnout.  
/Q: With options (specify the specification)  
Engineering unit indication: Sticker label attached  
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,  
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,  
40DT SPECIFICATIONS  
ES-9535 Rev.10 Page 1/6  
https://www.m-system.co.jp/  
MODEL: 40DT  
cm, mm, m, m/sec, mm/min, cm/min, m/min,  
m/h, m/s , inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m , m /sec,  
/min, m /h, Nm /h, N·m, N/m , g, kg, kg/h,  
STANDARDS & APPROVALS  
EU conformity:  
2
3
3
m3  
3
3
2
EMC Directive  
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,  
kJ, MJ, rpm, sec, min, pH, %, ppm, etc.  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
INPUT SPECIFICATIONS  
Thermocouple  
Installation Category II  
Pollution Degree 2  
Input to power: Reinforced insulation (300 V)  
RoHS Directive  
Input resistance: 1 MΩ minimum  
Burnout sensing: ≤ 0.1 μA  
Usable range (conformance range):  
K (CA) -150 to +1370℃ or -238 to +2498°F  
J (IC) -180 to +1000℃ or -292 to +1832°F  
T (CC) -170 to +400℃ or -274 to +752°F  
R 380 to 1760℃ or 716 to 3200°F  
Operational range:  
K (CA) -180 to +1400℃ or -292 to +2552°F  
J (IC) -210 to +1030℃ or -346 to +1886°F  
T (CC) -200 to + 430℃ or -328 to +806°F  
R 170 to 1790℃ or 338 to 3254°F  
■ Hold Input: Dry contact input  
Detecting level: ≤ 1.5 V  
Sensing: Approx. 5 V DC, 1 mA  
INSTALLATION  
Power consumption  
AC: Approx. 1.0 VA  
DC: Approx. 0.3 W  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Panel flush mounting  
Weight: 210 g (0.46 lb)  
PERFORMANCE  
Accuracy  
K narrow range (-150 – +400°C, -238 – +752°F ):  
±1°C rdg ± 1digit, ±2°F rdg ± 1digit  
K wide range (400 – 1370°C, 752 – 2498°F):  
±3℃ rdg ± 1digit, ±6°F rdg ± 1digit  
J: ±1℃ rdg ± 1digit, ±2°F rdg ± 1digit  
T: ±1℃ rdg ± 1digit, ±2°F rdg ± 1digit  
R: ±3℃ rdg ± 1digit, ±6°F rdg ± 1digit  
Cold junction compensation error:  
±3°C at 25 ±10°C  
±5.4°F at 77 ±18°F  
Temp. coefficient: ±0.1 ℃/℃  
Line voltage effect: ±2 digits over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @1 minute (input to power to  
ground)  
40DT SPECIFICATIONS  
ES-9535 Rev.10 Page 2/6  
https://www.m-system.co.jp/  
MODEL: 40DT  
DISPLAY HOLD COMMAND  
Displayed value is held with an external HOLD command input. Connect the contacts across HOLD to COM.  
(a)  
(c)  
5V–CMOS, TTL  
Photo-Coupler  
HOLD  
H
HOLD  
H
L
L
5
6
HOLD  
COM  
5
6
HOLD  
COM  
Photo-Coupler  
Twisted pair cable  
Twisted pair cable  
(b)  
Transistor  
(d)  
Relay  
HOLD  
H
HOLD  
H
L
L
5
6
HOLD  
COM  
5
6
HOLD  
COM  
Relay  
Twisted pair cable  
Twisted pair cable  
EXTERNAL VIEW  
(1) Front Panel  
(3) 4-digit Display  
(4) Polarity Indicator  
(8) Up Button  
(5) Disp/ Button  
(6) Scale/ Button  
(2) Sticker Label  
(7) Shift Button  
COMPONENT IDENTIFICATION  
No.  
(1)  
(2)  
(3)  
(4)  
COMPONENT  
Front panel  
FUNCTIONS  
Removed at conguration.  
Engineering unit label position  
4-digit LED display. Range: 0 to 9999  
Turns on when negative value is displayed  
Sticker label  
4-digit display  
Polarity indicator  
Used to move on to the display setting modes; or to shift through setting items in each  
setting mode.  
(5)  
(6)  
Disp/ button  
Scale/ button  
Used to move on to the zero & span adjustment modes; or to shift through setting items in  
each setting mode.  
Used to move on to the setting standby status and shift through display digits in each set-  
ting item.  
(7)  
(8)  
Shift button  
Up button  
Used to select setting value.  
40DT SPECIFICATIONS  
ES-9535 Rev.10 Page 3/6  
https://www.m-system.co.jp/  
MODEL: 40DT  
PARAMETER LIST  
■ ZERO & SPAN ADJUSTMENTS  
PARAMETER  
Input type  
DISPLAY  
FUNCTION  
DEFAULT VALUE  
K thermocouple (usable range -150 to +1370°C, -238 to +2498°F)  
J thermocouple (usable range -180 to +1000°C, -292 to +1832°F)  
T thermocouple (usable range -170 to +400°C, -274 to +752°F)  
R thermocouple (usable range 380 to 1760°C, 716 to 3200°F)  
Adjustment value for 0% of measurement range  
To distinguish from span adjustment, the "rst decimal point is blink-  
ing  
Zero adjustment  
Span adjustment  
Temperature unit  
Adjustment value for 100% of measurement range  
Display in Celsius  
Display in Fahrenheit  
■ DISPLAY SETTING MODE  
PARAMETER  
DISPLAY  
FUNCTION  
DEFAULT VALUE  
Moving Average  
No moving averaging  
Moving average with 2 samples  
Moving average with 4 samples  
Moving average with 8 samples  
Moving average with 16 samples  
Brightness level 1 (dark)  
Brightness level 2  
Brightness  
Brightness level 3  
Brightness level 4  
Brightness level 5 (bright)  
CJC sensor Enabled  
CJC Sensor  
CJC sensor Disabled  
Initialization  
Non-initialization  
Initialize settings (change to factory settings) *1  
Version Indication  
Version number, indication only  
*1. While “  
” is shown, pressing Disp/ button or Scale/ button initializes settings.  
Activating “initialization, user’s speci"ed parameters will be deleted and overwritten with the factory default values. Notice that after this,  
Ex-factory settings will be irrecoverable.  
40DT SPECIFICATIONS  
ES-9535 Rev.10 Page 4/6  
https://www.m-system.co.jp/  
MODEL: 40DT  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
TOP VIEW  
92 (3.62)  
FRONT VIEW  
SIDE VIEW  
103 (4.06)  
96 (3.78)  
96 (3.78)  
85 (3.35)  
11  
(.43)  
12 (.47)  
REAR VIEW  
10–M3 SCREW  
TERMINALS  
6.4 (.25)  
1
2
3
4
5
6
7
8
9
10  
MOUNTING REQUIREMENTS unit: mm  
92 +00.8  
min. 120  
Panel thickness: 1.6 to 8.0 mm  
40DT SPECIFICATIONS  
ES-9535 Rev.10 Page 5/6  
https://www.m-system.co.jp/  
MODEL: 40DT  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Comp. Leadwire  
THERMOCOUPLE  
+
+
1
2
3
4
U(+)  
V(–)  
-
9
10  
7
POWER  
A/D  
Converter  
CJC  
Digital  
Computation  
HOLD 5  
8
COM  
6
Display /  
Setting  
Specifications are subject to change without notice.  
40DT SPECIFICATIONS  
ES-9535 Rev.10 Page 6/6  
https://www.m-system.co.jp/  

相关型号:

40DT-T1-L3/Q

Digital Panel Meters 40 Series
MSYSTEM

40DT-T1-R

Digital Panel Meters 40 Series
MSYSTEM

40DT-T1-R/Q

Digital Panel Meters 40 Series
MSYSTEM

40DV01840

Interconnection Device,
SWITCH

40DV02440

Interconnection Device,
SWITCH

40DV03640

Interconnection Device,
SWITCH

40DV04840

Interconnection Device,
SWITCH

40DV07240

Interconnection Device,
SWITCH

40DV12040

Interconnection Device,
SWITCH

40E-1C-15.5

E Rated Medium Voltage Fuses
LITTELFUSE

40E-1C-15.5L

Electric Fuse, 40A, 15500VAC, 60000A (IR), Inline/holder
LITTELFUSE

40E-1C-15.5S

Electric Fuse, Medium Blow, 40A, 15500VAC, 80000A (IR), Inline/holder,
LITTELFUSE