Digital Panel Meters 47 Series
47DAC-118-R 数据手册
通过下载47DAC-118-R数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: 47DAC
3: Alarm output: N.O. photo MOSFET relay, 4 points
Digital Panel Meters 47 Series
4: Network interface: RS-485 / Modbus RTU
5: BCD output
AC INPUT DIGITAL PANEL METER
(5½ digit, LCD display type, true RMS sensing)
Functions & Features
6: Event trigger input
7: Alarm output: N.O. relay, 4 points
+ Network interface: RS-485 / Modbus RTU
8: Alarm output: SPDT relay, 2 points +
Network interface: RS-485 / Modbus RTU
9: Alarm output: N.O. photo MOSFET relay, 4 points + BCD output
A: Event trigger input + BCD output
• 5 1/2 digit AC input digital panel meter
• Scaling range -20000 to 100000
• 1/8 DIN size
• Display color can be changed at alarm
• Bargraph indicator shows approximate measuring status
• External event trigger input
[4] POWER INPUT
AC Power
• RS-485 / Modbus RTU output
• Infrared interface
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
• BCD output
DC Power
• Loop test output (DC output option)
• IP66 front panel
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
• Separable terminal block
• Safety terminal cover tethered to the device with a strap
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
96 (3.78)
[5] OPTIONS
blank: none
/Q: With options (specify the specification)
M
a
x
M
in
48
F
Z
T
Z
(1.89)
H
ld
TG
N
G
Zr
o
Sp
n
Tc
h
Ma
x/M
in
A
la
rm
/
S
ca
le
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
/
S
hif
t
U
p
98.5 (3.88)
mm (inch)
/C02: Polyurethane coating
MODEL: 47DAC-[1][2][3]-[4][5]
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
ORDERING INFORMATION
• Code number: 47DAC-[1][2][3]-[4][5]
Specify a code from below for each [1] through [5].
(e.g. 47DAC-111-M2/Q)
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9518)
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
RELATED PRODUCTS
• Connector terminal block (model: CNT)
[1] INPUT
1: AC voltage
2: AC current
• Special cable (model: HDR40)
• Infrared Communication Adaptor (model: COP-IRU)
• PC configurator software (model: 47DCFG)
Downloadable at M-System’s web site.
[2] DC OUTPUT
0: Without
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Degree of protection: IP66; applicable to the front of the
panel meter mounted according to the specified panel
cutout
1: With
[3] I/O OPTIONS
0: None
Connection
1: Alarm output: N.O. relay, 4 points
2: Alarm output: SPDT relay, 2 points
Input, DC output, relay output, network interface, power:
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 1/12
http://www.m-system.co.jp/
MODEL: 47DAC
M3 separable screw terminal (torque 0.6 N·m)
Photo MOSFET relay, event trigger input: Euro Type
Connector Terminal
LL indicator: Turns on in red when the LL alarm is tripped.
L indicator: Turns on in red when the L alarm is tripped.
H indicator: Turns on in green when the H alarm is tripped.
HH indicator: Turns on in green when the HH alarm is
tripped.
(applicable wire size: max. 1.3 dia., 0.5 – 1.25 mm
2,
stripped length 7 - 8 mm)
BCD output: 50-pin connector
P indicator: Turns on in amber when none of the other
alarms is tripped.
(Honda Tsushin Kogyo HDR-EC50LFDT1-SLE+)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
Status indicators: Max, Min, FZ, TZ
Display max./min. value, Amber LED turns on at
forced zero mode and tare adjustment mode
Function indicators
Housing material: Flame-resistant resin (gray)
Isolation: Input to DC output to HH output or H output to L
output or LL output to network or BCD output or event
trigger input to power
Hld: Turns on in green when HOLD signal is ON
TG: Turns on in green when TIMING signal is ON
NG: Blinking in green when a parameter is invalid
Zro: Turns on in green at zero setting of scaling setting
mode
Input waveform: Up to 15 % of 3rd harmonic content
Infrared communication: Transmission distance max. 1
meter (for use with the COP-IRU)
Setting: (Front button)
Spn: Turns on in green at span setting of scaling setting
mode
• Scaled range
• Input type
Tch: Turns on in green at input scaling, blinking in red at
teach calibration
• Alarm setpoint
• Hysteresis (deadband)
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
• Averaging
• Others
(Refer to the instruction manual for details)
Sampling rate: 20 times/sec. (50 msec.)
Averaging: Simple average, moving average or no
averaging
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,
m3
/min, m
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.
Lockout setting: Prohibiting certain operations; protecting
settings
INPUT SPECIFICATIONS
Input frequency: 40 Hz – 1 kHz
DISPLAY
Main display: 5½ digits, LCD with LED backlight, 7-segment,
Overload capacity: 200 % of rating for 10 sec.,
110 % of rating continuous
14.2 mm (.56) high
Color: Red or green changeable at alarm
Scaling range: -20000 to 100000
INPUT CODE: 1 (AC voltage)
MEASURING OPERATIONAL
INPUT
TYPE ID
RANGE
0 – 0.2 V
0 – 2 V
RANGE
0 – 0.22 V
0 – 2.2 V
0 – 22 V
0 – 220 V
IMPEDANCE
1 MΩ minimum
1 MΩ minimum
1 MΩ minimum
1 MΩ minimum
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none
Zero indication: Higher-digit zeros are suppressed.
Sub display: 7 digits, LCD with LED backlight, 7-segment,
5.5 mm (.22) high
0 – 20 V
0 – 200 V
Color: Green
INPUT CODE: 2 (AC current)
MEASURING OPERATIONAL
Over-range indication: ‘-20000’ or ‘100000’ blinking for
display values out of the scaled range (decimal point
position depending upon setting). ‘S.ERR’ (main display)
and ‘OVER’ (sub display) blinking when the input signal is
out of the usable range.
INPUT
IMPEDANCE
TYPE ID
RANGE
0 – 0.2 mA
0 – 2 mA
RANGE
0 – 0.22 mA
0 – 2.2 mA
0 – 22 mA
0 – 220 mA
100 Ω
100 Ω
1 Ω
0 – 20 mA
0 – 200 mA
Bargraph
1 Ω
No. of LED segments: 20, displayed with divided by 10
Color: Amber
Alarm status indication
All setpoints can be set and indicated regardless of alarm
output options. Each is independently set either for Hi or Lo
alarm trip.
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 2/12
http://www.m-system.co.jp/
MODEL: 47DAC
Node address: 1 to 247
DC OUTPUT SIGNAL SPECIFICATIONS
VOLTAGE OUTPUT
Media: Shielded twisted-pair cable (CPEV-S 0.9 dia.)
Terminating resistor: Built-in (Connect across T2 - T3, when
the unit is the end of the line)
■ BCD Output + Control Signals
• Input Signals: Dry contact or NPN open collector
Input current: ≤ 3 mA
OUTPUT OPERATIONAL
LOAD
RESISTANCE
TYPE ID
RANGE
0 – 5V
5V
RANGE
-0.5
–
+5.5V
2000Ω minimum
4000Ω minimum
8000Ω minimum
-6 – +6V
-12 – +12V
10V
Sensing: 6 V
CURRENT OUTPUT
OUTPUT OPERATIONAL
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF
Signal ID and Details
LOAD
RESISTANCE
TYPE ID
RANGE
0 – 20mA
4 – 20mA
RANGE
-2 – +22mA
400Ω maximum
REQ: Request BCD data
2.4 – 21.6mA 400Ω maximum
Valid data in approx. 30 msec. after detecting
the signal’s rising edge
MIN_REQ: Request Minimum reading data
Valid data in approx. 30 msec. after detecting
the signal’s rising edge
I/O OPTIONS
■ Event Trigger Input: Dry contact or NPN open collector
Input current: ≤ 3 mA
MAX_REQ: Request Maximum reading data
Valid data in approx. 30 msec. after detecting
the signal’s rising edge
Sensing: 6 V
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF
Signal ID and Details
HOLD: Hold data
S-TMR: Startup Timer
Reading measured signal stops and the last value
is held when HOLD signal is turned on.
RESET: Reset data
Measuring starts in the predetermined time after detecting
the signal turning on.
TIMING: Timing
All BCD data turn off when RESET signal is turned
on.
Used for various timing hold functions
ZERO: Forced Zero
• Output Signals: NPN open collector
Max. load voltage: 24 V DC
Forced Zero and tare adjustment are externally controlled
when ZERO signal is turned on/off.
HOLD: Hold data
Max. load current: 10 mA
Saturation voltage: ≤ 0.3 V
Reading measured signal stops and the last
value is held when HOLD signal is turned on.
RESET: Reset data
Leakage current: ≤ 500 μA
Signal ID and Details
DATA (Do 11...Do 68): BCD Output data in 6 digits
Do 1x = LSD ... Do 6x = 6th LSD
POL: BCD Polarity
The device is reset when RESET signal is turned on.
■ Alarm Output: Relay contact
Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
ON = (–), OFF = (+)
OVF: BCD Overflow/underflow (scaling error)
Output given at overflow or underflow (scaling error)
DAV: Data Valid
Maximum switching voltage: 250 V AC, 30 V DC
Maximum switching power: 750 VA, 90 W (resistive load)
Minimum load: 5 V DC @ 10 mA
ON = valid, OFF = invalid
Mechanical life: ≥ 5 × 10 cycles (rate 180 cycles/min.)
6
RUN: Run
■ Alarm Output: Photo MOSFET relay
Rated load: 120 V AC/DC @ 80 mA (resistive load)
ON resistance: 25 Ω
Means the meter is functioning.
OFF = Error except the scaling error
No DAV or DATA output is given when
RUN signal is not provided.
Permissible loss: 250 mW
■ Network Interface
• Alarm Output Signals: NPN open collector
Max. load voltage: 24 V DC
Transmission: Half-duplex, asynchronous, no procedure
Interface: Conforms to TIA/EIA-485-A
Max. transmission distance: 500 meters
Baud rate: 1.2 – 38.4 kbps
Max. load current: 50 mA
Saturation voltage: ≤ 1.1 V
Leakage current: ≤ 500 μA
Max. number of nodes: 31 (except the master)
Protocol: Modbus RTU
Signal ID and Details
HH: HH alarm trip output
Parity: None, odd or even
H: H alarm trip output
Stop bit: 1 bit, 2 bits
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 3/12
http://www.m-system.co.jp/
MODEL: 47DAC
PASS: PASS zone output
L: L alarm trip output
LL: LL alarm trip output
INSTALLATION
Power consumption
•AC:
Approx. 8 VA at 100 V
Approx. 10 VA at 200 V
Approx. 12 VA at 264 V
•DC: 3.5 W max.
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting
Weight: 300 g (0.66 lb)
PERFORMANCE
Accuracy
Display: ±0.5 % ±10 digits with input 5 – 100 %
Output: ±0.1 %
(DC output = display + output)
Temp. coefficient: ±0.05 %/°C (±0.03 %/°F)
Input resolution: Max. 19 bits
Output resolution: Max. 14 bits
Response time: ≤ 0.5 sec.
(alarm output: 0 – 100 % at 90 % setpoint)
≤ 0.5 sec. (DC output: 0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(input to DC output to HH output or H output to L output or
LL output to network or BCD output or event trigger input to
power to ground)
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 4/12
http://www.m-system.co.jp/
MODEL: 47DAC
EXTERNAL VIEW
(3) Status Indicators
(1) Main Display
(4) Alarm Indicators
Max
Min
FZ
HH
H
P
(5) Bargraph
TZ
L
Hld TG NG Zro Spn Tch
LL
(2) Sub Display
(6) Function Indicators
Max/Min
Alarm/
Scale/
Shift
Up
(12) Up Button
(11) Shift Button
(10) Scale/ Button
(7) Infrared Interface
(8) Max/Min Button
(9) Alarm/ Button
• COMPONENT IDENTIFICATION
No. COMPONENT FUNCTION
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Main display
Sub display
Indicates present values, setting values and status of the unit.
Indicates the present setting mode.
Status indicators
Alarm indicators
Bargraph
Indicate Max/Min display mode, Forced zero mode and Tare adjustment mode.
Indicate alarm status of the input signal.
Indicates present signal level against the scaled range.
Function indicators Indicate the device status.
Infrared interface
Max/Min button
Alarm/ button
Used for the infrared communication.
Used to switch the main display to show present values, maximum values or minimum values etc.
Used to confirm alarm setpoints and to move on to the alarm and other setting modes; or to shift
through setting items in each setting mode.
(10) Scale/ button
Used to move on to the scaling and other setting modes; or to shift through setting items in each
setting mode.
(11) Shift button
(12) Up button
Used to move on to the setting standby status and shift through display digits in each setting item.
Used to change and apply setting values; or to execute/cancel Forced Zero and tare adjustment.
Note: Refer to the operating manual for details on each function.
COMMUNICATION CABLE CONNECTIONS
R2K-1
RS-485
RS-485
47Dx
T1
47Dx
T1
T1
T2
T3
T4
RS-232-C
T2
T2
1
1
*
*
T3
T3
T4
T4
2
*
FG
*1. Internal terminating resistor is used when the device is at the end of a transmission line.
*2. Install shield cables to all sections and ground them at single point.
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 5/12
http://www.m-system.co.jp/
MODEL: 47DAC
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
■ TOP VIEW
95 (3.74)
■ FRONT VIEW
■ SIDE VIEW
103 (4.06)
96 (3.78)
98.5 (3.88)
86 (3.39)
12.5 (.49)
2 (.08)
■ REAR VIEW
10–M3 SCREW
TERMINAL
20–M3 SCREW
TERMINAL
• Alarm Output, RS-485/Modbus
• No Options
6.6 (.26)
2–M3 SCREW
4–M3 SCREW
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
20
11
12
13
14
15
16
17
18
19
91.5 (3.60)
•
BCD Output, Event Trigger Input, Alarm Output (Photo MOSFET Relay)
10–M3 SCREW
TERMINAL
2–M3 SCREW
1
2
3
4
5
6
7
8
9
10
1B
1A
25B
25A
11 12 13 14 15 16
EURO TYPE
50-pin CONNECTOR
CONNECTOR TERMINAL
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 6/12
http://www.m-system.co.jp/
MODEL: 47DAC
MOUNTING REQUIREMENTS unit: mm
92 +– 00.8
min. 120
Panel thickness: 1.6 to 8.0 mm
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ REAR TERMINAL ASSIGNMENTS
TERMINAL A
1
2
3
4
5
6
7
8
9
10
20
1
2
3
4
5
6
7
8
9
10
TERMINAL D
11
12
13
14
15
16
17
18
19
TERMINAL C
TERMINAL B
1B
1A
25B
25A
11 12 13 14 15 16
■ TERMINAL A: BASIC
Isolation
1
2
3
4
5
6
Output
Driver
+
7
8
9
DC OUTPUT
200 / 20
2 / 0.2
+
–
A/D
Converter
+
Digital
Computation
U(+)
Display /
Setting
POWER
INPUT
10 V(–)
COM –
Infrared
Interface
Note: The section enclosed by broken line is only with DC output option.
• Input Terminal Assignments
INPUT CODE: 1
INPUT CODE: 2
MEASURING
RANGE
INPUT
TERMINALS
MEASURING
RANGE
INPUT
TERMINALS
TYPE ID
TYPE ID
3 – 5
3 – 5
3 – 5
2 – 5
2 – 5
0 – 0.2 mA
0 – 2 mA
0 – 0.2 V
0 – 2 V
3 – 5
2 – 5
2 – 5
0 – 20 mA
0 – 200 mA
0 – 20 V
0 – 200 V
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 7/12
http://www.m-system.co.jp/
MODEL: 47DAC
■ TERMINAL B
• Alarm Output : N.O. contact, 4 points
• Alarm Output : SPDT contact, 2 points
Ry
11
11
12
13
14
Ry
15 HHa
16 Ha
15 Ha(NO)
16 Hb(NC)
Ry
HH OUTPUT
L OUTPUT
12
13
14
H OUTPUT
L OUTPUT
H OUTPUT
Digital
Computation
Digital
Computation
17 Hc, HHc
17 Hc(COM
18 La(NO)
19 Lb(NC)
)
Ry
Ry
Ry
18 La
19 LLa
LL OUTPUT
20 Lc, LLc
20 Lc(COM
)
■ Relay Protection
• AC Powered
• RS-485 / Modbus RTU
Inductive
Load (Coil)
Isolation
15
16
17
18
19
20
Shielded Twisted-pair Cable
Digital
Computation
Output
Driver
Varistor or
CR Circuit
+
–
T1
T2
T3
T4
11
12
13
14
To other
Modbus devices
LOAD
Term.
Resist.
U
Jumper *1
• DC Powered
Inductive
Load (Coil)
Diode, Varistor or
CR Circuit
LOAD
*1. When the device is located at the end of a transmission line via twisted-pair cable
(when there is no cross-wiring), close across the terminal 12 – 13 with a leadwire.
When the device is not at the end, no shortcircuit wire is required.
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 8/12
http://www.m-system.co.jp/
MODEL: 47DAC
■ TERMINAL C : BCD OUTPUT
• Connector Pin Assignment
Isolation
PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT
Digital
Computation
BCD
Output
1B
1A
25B
25A
1A
2A
COM
COM
LL
1B
2B
Do 38
COM
Do 34
COM
Do 32
COM
Do 31
COM
Do 28
COM
Do 24
COM
Do 22
COM
Do 21
Do 68
Do 18
Do 64
Do 14
Do 62
Do 12
Do 61
Do 11
COM
COM
3A
3B
4A
L
4B
5A
PASS
H
5B
6A
6B
7A
HH
7B
8A
POL
8B
9A
RESET
HOLD
MIN_REQ
MAX_REQ
REQ
9B
10A
11A
12A
13A
14A
15A
16A
17A
18A
19A
20A
21A
22A
23A
24A
25A
10B
11B
12B
13B
14B
15B
16B
17B
18B
19B
20B
21B
22B
23B
24B
25B
• Open collector
COM
RUN
Output
DAV
OVF
Do 58
Do 54
Do 52
Do 51
Do 48
Do 44
Do 42
Do 41
• Output Logic
Voltage Level at ON
Output Logic
Positive
Hi
Lo
Negative
• Connected to a PLC (example)
• Connected to a digital display (example)
Digital Panel Meter
+24 V
DC Power Supply
COM
+6 V
0 V
Digital Panel Meter
+6 V
shortcircuit
2 kΩ
REQ
PLC Transistor Output Unit
1.5 kΩ
2 kΩ
REQ
OUT
OUT
2 kΩ
1.5 kΩ
9A
RESET
1.5 kΩ
2 kΩ
9A
RESET
COM
Do11
Do12
Do14
Do18
1.5 kΩ
COM
(0 V)
23B
21B
19B
17B
24 V DC
1st LSD
BCD Input Module
COM
Do11
Do12
Do14
Do18
COM
IN
23B
21B
19B
17B
6th LSD
2nd LSD
16A
15A
8A
DAV
RUN
POL
IN
1st LSD
IN
IN
(polarity +, –)
16A
15A
8A
DAV
RUN
POL
IN
IN
IN
Digital Display
Use Special cable (model: HDR40) and Connector Terminal Block
(model: CNT).
Refer to the cable’s data sheet for pin assignments.
(polarity +, –)
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 9/12
http://www.m-system.co.jp/
MODEL: 47DAC
■ TERMINAL D
• Alarm Output : Photo MOSFET Relay N.O. contact, 4 points
• Event Trigger Input
Isolation
Ry
Digital
Computation
11 HHa
11 TIMING
12 S-TMR
Ry
HH OUTPUT
12 Ha
H OUTPUT
Digital
Computation
13 Hc, HHc
13 HOLD
14 RESET
15 ZERO
16 COM
Digital
Computation
Ry
Ry
14 La
L OUTPUT
15 LLa
LL OUTPUT
16 Lc, LLc
Connection Example
TIMING : 11
S-TMR : 12
HOLD : 13
RESET : 14
ZERO : 15
+6 V
2 kΩ
1.5 kΩ
NPN
dry
contact
open
collector
16
COM
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 10/12
http://www.m-system.co.jp/
MODEL: 47DAC
BCD OUTPUT TIMING CHART
VIEWING ANGLE
Request signals (REQ, MAX_REQ, MIN_REQ) from an external
device (e.g. PLC) are required in order to read out BCD data.
All signals in the following charts are in the negative logic
(ON at LOW signal, as factory set).
The display is designed to provide the optimal legibility
when viewed from the angles as shown below.
• Timing Chart for Continuous Data Output
REQ
MAX_REQ Hi
MIN_REQ
Lo
*1
Hi
DATA
DAV
all data H
data
data
Lo
Hi
Lo
30 ms
approx.
40 ms
24 ms
40 ms
24 ms
64 ms
64 ms
Measured data is output every 64 ms while one of REQ signals (REQ,
MAX_REQ or MIN_REQ) remains ON. For Event trigger modes, the data
value is the same as the display.
• Timing Chart for Single Sampling Cycle Data Output
20 ms or wider (max. 50 ms)
REQ
MAX_REQ Hi
MIN_REQ
Lo
*1
DATA
Hi
all data H
data
all data H
Lo
Hi
DAV
Lo
30 ms
approx.
40 ms
16 ms
When one of REQ signals (REQ, MAX_REQ or MIN_REQ) is given and
its width is between 20 and 50 ms, DATA is established and DAV output
is given in approx. 30 ms from the falling edge of the REQ signal.
Read in the data to a PLC at the timing of the DAV output signal.
DAV is turned off in 40 ms. DATA is turned off in 16 ms after that.
•
Output is provided via open collector, enabling wired-OR gate configuration
REQ 1 Hi
Lo
Hi
REQ 2
Lo
Hi
Lo
Hi
REQ 3
*1
DATA
1
2
3
Lo
Hi
DAV
Lo
*2
*2
*2
When DATA output logic is negative, wired-OR connection is available
for BCD data, POL, OVF, HH, H, P, L and LL signals.
*1. DATA includes BCD Output, POL, OVF, HH, H, P, L, LL and RUN.
*2. Wait for at least 20 ms between DAV turning off and the next REQ signal.
REQ 1
47Dx
1
REQ 2
47Dx
2
PLC
REQ 3
47Dx
3
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 11/12
http://www.m-system.co.jp/
MODEL: 47DAC
SYSTEM CONFIGURATION EXAMPLES
■ RS-485 / RS-232-C
■ RS-485 / ETHERNET
RS-232-C
Ethernet
RS-232-C/RS-485
Converter
(model: R2K-1 or LK1)
Communication Adaptor
(model: 72EM2-M4)
ETHERNET
RS-485
RUN
SEND
FIELD
CNFG
Lightning Surge Protector
for RS-485/422
(model: MD74R or MDP-4R) *1
Lightning Surge Protector
for RS-485/422
(model: MD74R or MDP-4R) *1
RS-485 (Modbus RTU)
RS-485 (Modbus RTU)
Lightning Surge
Protector for
RS-485/422
(model: MD74R
or MDP-4R) *1
Lightning Surge
Protector for
RS-485/422
(model: MD74R
or MDP-4R) *1
M
M
FZ
TZ
M
Mi
FZ
TZ
Max
ax
in
ax
n
M
M
FZ
TZ
M
Mi
FZ
TZ
M
M
FZ
TZ
ax
in
ax
n
ax
in
M
in
FZ
TZ
Hld
Hld
Hld
TG
NG
TG
TG
Hld
Hld
Hld
NG
NG
TG
TG
TG
Zr
o
Zr
o
Zr
o
NG
NG
NG
Spn
Sp
Spn
Tc
n
Zr
Zr
Zr
Tc
Tc
o
o
o
Sp
n
h
h
h
Spn
Sp
n
Tc
Tc
Tc
h
h
h
Digital Panel Meter
(model: 47Dx)
Digital Panel Meter
(model: 47Dx)
*1. Insert lightning surge protectors recommended in this example if necessary.
Specifications are subject to change without notice.
47DAC SPECIFICATIONS
ES-9518 Rev.4 Page 12/12
http://www.m-system.co.jp/
47DAC-118-R 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
47DAC-118-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-119-M2 | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-119-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-119-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-119-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-119-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-119-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-11A-M2 | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-11A-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DAC-11A-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 |
47DAC-118-R 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8