MODEL: 47DV  
Digital Panel Meters 47 Series  
[4] I/O OPTIONS  
0: None  
1: Alarm output: N.O. relay, 4 points  
2: Alarm output: SPDT relay, 2 points  
3: Alarm output: N.O. photo MOSFET relay, 4 points  
(CE not available)  
DC INPUT DIGITAL PANEL METER  
(5½ digit, LCD display type)  
Functions & Features  
• 5 1/2 digit DC input digital panel meter  
• Scaling range -20000 to 100000  
• 1/8 DIN size  
4: Network interface: RS-485 / Modbus RTU  
5: BCD output  
6: Event trigger input  
• Display color can be changed at alarm  
• Bargraph indicator shows approximate measuring status  
• 12 V or 24 V excitation supply  
• External event trigger input  
• RS-485 / Modbus RTU output  
• Infrared interface  
7: Alarm output: N.O. relay, 4 points  
+ Network interface: RS-485 / Modbus RTU  
8: Alarm output: SPDT relay, 2 points +  
Network interface: RS-485 / Modbus RTU  
9: Alarm output: N.O. photo MOSFET relay, 4 points + BCD output  
(CE not available)  
• BCD output  
A: Event trigger input + BCD output  
• Loop test output (DC output option)  
• IP66 front panel  
• Separable terminal block  
[5] POWER INPUT  
• Safety terminal cover tethered to the device with a strap  
AC Power  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)  
DC Power  
96 (3.78)  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
M
a
x
M
in  
48  
(1.89)  
F
Z
T
Z
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
H
ld  
TG  
N
G
Zr  
o
Sp  
n
Tc  
h
Ma  
x/M  
in  
A
la  
rm  
/
S
ca  
le  
/
S
hif  
t
U
p
98.5 (3.88)  
[6] OPTIONS  
blank: none  
mm (inch)  
/Q: With options (specify the specification)  
MODEL: 47DV-[1][2][3][4]-[5][6]  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
Moving parts and indicators are not coated.  
/C01: Silicone coating  
ORDERING INFORMATION  
• Code number: 47DV-[1][2][3][4]-[5][6]  
Specify a code from below for each of [1] through [6].  
(e.g. 47DV-1111-M2/Q)  
/C02: Polyurethane coating  
/C03: Rubber coating  
• Specify the specification for option code /Q  
(e.g. /C01/S01/SET)  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-9501)  
[1] INPUT  
1: DC voltage  
2: DC current  
RELATED PRODUCTS  
• Resistor module (model: REM2-250)  
• Connector terminal block (model: CNT)  
• Special cable (model: HDR40)  
[2] DC OUTPUT  
0: Without  
1: With  
• Infrared Communication Adaptor (model: COP-IRU)  
• PC configurator software (model: 47DCFG)  
Downloadable at M-System’s web site.  
[3] EXCITATION SUPPLY  
1: +12 V sensor excitation  
2: +24 V two-wire transmitter excitation  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 1/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
Bargraph  
GENERAL SPECIFICATIONS  
Construction: Panel flush mounting  
Degree of protection: IP66; applicable to the front of the  
panel meter mounted according to the specified panel  
cutout  
No. of LED segments: 20, displayed with divided by 10  
Color: Amber  
Alarm status indication  
All setpoints can be set and indicated regardless of alarm  
output options. Each is independently set either for Hi or Lo  
alarm trip.  
Connection  
Input, excitation supply, DC output, relay output,  
network interface, power: M3 separable screw terminal  
(torque 0.6 N·m)  
LL indicator: Turns on in red when the LL alarm is tripped.  
L indicator: Turns on in red when the L alarm is tripped.  
H indicator: Turns on in green when the H alarm is tripped.  
HH indicator: Turns on in green when the HH alarm is  
tripped.  
Photo MOSFET relay, event trigger input: Euro Type  
Connector Terminal  
(applicable wire size: max. 1.3 dia., 0.5 – 1.25 mm  
2,  
P indicator: Turns on in amber when none of the other  
alarms is tripped.  
stripped length 7 - 8 mm)  
BCD output: 50-pin connector  
Status indicators: Max, Min, FZ, TZ  
(Honda Tsushin Kogyo HDR-EC50LFDT1-SLE+)  
Display max./min. value, Amber LED turns on at  
forced zero mode and tare adjustment mode  
Function indicators  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
Housing material: Flame-resistant resin (gray)  
Isolation: Input or excitation supply to DC output to  
HH output or H output to L output or LL output to network or  
BCD output or event trigger input to power  
Infrared communication: Transmission distance max. 1  
meter (for use with the COP-IRU)  
Setting: (Front button)  
Hld: Turns on in green when HOLD signal is ON  
TG: Turns on in green when TIMING signal is ON  
NG: Blinking in green when a parameter is invalid  
Zro: Turns on in green at zero setting of scaling setting  
mode  
Spn: Turns on in green at span setting of scaling setting  
mode  
• Scaled range  
Tch: Turns on in green at input scaling, blinking in red at  
teach calibration  
• Input type  
• Alarm setpoint  
Engineering unit indication: Sticker label attached  
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,  
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,  
cm, mm, m, m/sec, mm/min, cm/min, m/min,  
• Hysteresis (deadband)  
• Averaging  
• Others  
(Refer to the instruction manual for details)  
Sampling rate: 20 times/sec. (50 msec.)  
Averaging: Simple average, moving average or no  
averaging  
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,  
m3  
/min, m  
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,  
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,  
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.  
Lockout setting: Prohibiting certain operations; protecting  
settings  
EXCITATION SUPPLY  
+12V SENSOR EXCITATION  
Output voltage (across the terminals 5 – 6): 12 – 16 V DC  
with no load  
DISPLAY  
Main display: 5½ digits, LCD with LED backlight, 7-segment,  
14.2 mm (.56) high  
10.8 V DC minimum at 80 mA  
Current rating: 84 mA DC maximum  
Shortcircuit Protection  
Color: Red or green changeable at alarm  
Scaling range: -20000 to 100000  
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none  
Zero indication: Higher-digit zeros are suppressed.  
Sub display: 7 digits, LCD with LED backlight, 7-segment,  
5.5 mm (.22) high  
Current limited: 97 mA maximum  
Protected time duration: No limit  
+24V TWO-WIRE TRANSMITTER EXCITATION  
Output voltage (across the terminals 5 – 6): 24 – 28 V DC  
with no load  
Color: Green  
Over-range indication: ‘-20000’ or ‘100000’ blinking for  
display values out of the scaled range (decimal point  
position depending upon setting). ‘S.ERR’ (main display)  
and ‘UNDER’ or ‘OVER’ (sub display) blinking when the input  
signal is out of the usable range.  
22 V DC minimum at 20 mA  
Current rating: ≤ 22 mA DC  
• Shortcircuit Protection  
Current limited: 30 mA max.  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 2/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
Protected time duration: No limit  
Rated load: 250 V AC @ 3 A (cos ø = 1)  
30 V DC @ 3 A (resistive load)  
Maximum switching voltage: 250 V AC, 30 V DC  
Maximum switching power: 750 VA, 90 W (resistive load)  
Minimum load: 5 V DC @ 10 mA  
INPUT SPECIFICATIONS  
INPUT CODE: 1 (DC voltage)  
MEASURING OPERATIONAL  
TYPE ID  
INPUT  
IMPEDANCE  
Mechanical life: ≥ 5 × 10 cycles (rate 180 cycles/min.)  
6
RANGE  
RANGE  
Alarm Output: Photo MOSFET relay  
Rated load: 120 V AC/DC @ 80 mA (resistive load)  
ON resistance: 25 Ω  
1 – 5V  
0.6 – 5.4V  
1Mminimum  
1Mminimum  
1Mminimum  
5V  
-6 – +6V  
20V  
-24 – +24V  
Permissible loss: 250 mW  
200V  
-240 – +240V 1Mminimum  
Network Interface  
INPUT CODE: 2 (DC current)  
MEASURING OPERATIONAL  
Transmission: Half-duplex, asynchronous, no procedure  
Interface: Conforms to TIA/EIA-485-A  
Max. transmission distance: 500 meters  
Baud rate: 1.2 – 38.4 kbps  
INPUT  
IMPEDANCE  
TYPE ID  
RANGE RANGE  
4 – 20mA 2.4 – 21.6mA  
10Ω  
10Ω  
10Ω  
1Ω  
0 – 20mA  
20mA  
-2 – +22mA  
Max. number of nodes: 31 (except the master)  
Protocol: Modbus RTU  
-24 – +24mA  
200mA -240 – +240mA  
Parity: None, odd or even  
Stop bit: 1 bit, 2 bits  
Node address: 1 to 247  
DC OUTPUT SIGNAL SPECIFICATIONS  
VOLTAGE OUTPUT  
Media: Shielded twisted-pair cable (CPEV-S 0.9 dia.)  
Terminating resistor: Built-in (Connect across T2 - T3, when  
the unit is the end of the line)  
OUTPUT OPERATIONAL  
LOAD  
RESISTANCE  
TYPE ID  
RANGE  
0 5V  
5V  
RANGE  
-0.5  
+5.5V  
2000Ω minimum  
4000Ω minimum  
8000Ω minimum  
BCD Output + Control Signals  
Input Signals: Dry contact or NPN open collector  
Input current: ≤ 3 mA  
-6 +6V  
-12 +12V  
10V  
Sensing: 6 V  
CURRENT OUTPUT  
OUTPUT OPERATIONAL  
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF  
Signal ID and Details  
LOAD  
RESISTANCE  
TYPE ID  
RANGE  
0 20mA  
4 20mA  
RANGE  
-2 +22mA  
400Ω maximum  
REQ: Request BCD data  
2.4 21.6mA 400Ω maximum  
Valid data in approx. 30 msec. after detecting  
the signal’s rising edge  
MIN_REQ: Request Minimum reading data  
Valid data in approx. 30 msec. after detecting  
the signal’s rising edge  
I/O OPTIONS  
Event Trigger Input: Dry contact or NPN open collector  
Input current: ≤ 3 mA  
MAX_REQ: Request Maximum reading data  
Valid data in approx. 30 msec. after detecting  
the signal’s rising edge  
Sensing: 6 V  
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF  
Signal ID and Details  
HOLD: Hold data  
S-TMR: Startup Timer  
Reading measured signal stops and the last value  
is held when HOLD signal is turned on.  
RESET: Reset data  
Measuring starts in the predetermined time after detecting  
the signal turning on.  
TIMING: Timing  
All BCD data turn off when RESET signal is turned  
on.  
Used for various timing hold functions  
ZERO: Forced Zero  
Output Signals: NPN open collector  
Max. load voltage: 24 V DC  
Forced Zero and tare adjustment are externally controlled  
when ZERO signal is turned on/off.  
HOLD: Hold data  
Max. load current: 10 mA  
Saturation voltage: ≤ 0.3 V  
Reading measured signal stops and the last  
value is held when HOLD signal is turned on.  
RESET: Reset data  
Leakage current: ≤ 500 μA  
Signal ID and Details  
DATA (Do 11...Do 68): BCD Output data in 6 digits  
Do 1x = LSD ... Do 6x = 6th LSD  
The device is reset when RESET signal is turned on.  
Alarm Output: Relay contact  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 3/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
POL: BCD Polarity  
STANDARDS & APPROVALS  
EU conformity:  
ON = (–), OFF = (+)  
OVF: BCD Overflow/underflow (scaling error)  
Output given at overflow or underflow (scaling error)  
DAV: Data Valid  
EMC Directive  
EN 61326-1  
Low Voltage Directive  
ON = valid, OFF = invalid  
RUN: Run  
EN 61010-1  
Measurement Category II (input, alarm output)  
Installation Category II (power)  
Pollution degree 2  
Means the meter is functioning.  
OFF = Error except the scaling error  
No DAV or DATA output is given when  
RUN signal is not provided.  
Alarm Output Signals: NPN open collector  
Max. load voltage: 24 V DC  
Max. load current: 50 mA  
Saturation voltage: ≤ 1.1 V  
Leakage current: ≤ 500 μA  
Signal ID and Details  
Input or excitation supply or DC output to alarm output to  
power: Reinforced insulation (300 V)  
Input or excitation supply to DC output:  
Basic insulation (300 V)  
RoHS Directive  
HH: HH alarm trip output  
H: H alarm trip output  
PASS: PASS zone output  
L: L alarm trip output  
LL: LL alarm trip output  
INSTALLATION  
Power consumption  
AC: Max. 12 VA  
DC: ≤ 3.5 W  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Panel flush mounting  
Weight: 300 g (0.66 lb)  
PERFORMANCE  
Accuracy  
Display Voltage input: ±0.03 % ±1 digit  
Current input: ±0.1 % ±1 digit  
Output: ±0.1 % (DC output = display + output)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Input resolution: Max. 19 bits  
Output resolution: Max. 14 bits  
Response time: ≤ 0.5 sec.  
(alarm output: 0 – 100 % at 90 % setpoint)  
≤ 0.5 sec. (DC output: 0 – 90 %)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @ 1 minute  
(input or excitation supply to DC output to HH output or H  
output to L output or LL output to network or BCD output or  
event trigger input to power to ground)  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 4/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
EXTERNAL VIEW  
(3) Status Indicators  
(1) Main Display  
(4) Alarm Indicators  
Max  
Min  
FZ  
HH  
H
P
(5) Bargraph  
TZ  
L
Hld TG NG Zro Spn Tch  
LL  
(2) Sub Display  
(6) Function Indicators  
Max/Min  
Alarm/  
Scale/  
Shift  
Up  
(12) Up Button  
(11) Shift Button  
(10) Scale/ Button  
(7) Infrared Interface  
(8) Max/Min Button  
(9) Alarm/ Button  
• COMPONENT IDENTIFICATION  
No. COMPONENT FUNCTION  
(1)  
(2)  
(3)  
(4)  
(5)  
(6)  
(7)  
(8)  
(9)  
Main display  
Sub display  
Indicates present values, setting values and status of the unit.  
Indicates the present setting mode.  
Status indicators  
Alarm indicators  
Bargraph  
Indicate Max/Min display mode, Forced zero mode and Tare adjustment mode.  
Indicate alarm status of the input signal.  
Indicates present signal level against the scaled range.  
Function indicators Indicate the device status.  
Infrared interface  
Max/Min button  
Alarm/ button  
Used for the infrared communication.  
Used to switch the main display to show present values, maximum values or minimum values etc.  
Used to confirm alarm setpoints and to move on to the alarm and other setting modes; or to shift  
through setting items in each setting mode.  
(10) Scale/ button  
Used to move on to the scaling and other setting modes; or to shift through setting items in each  
setting mode.  
(11) Shift button  
(12) Up button  
Used to move on to the setting standby status and shift through display digits in each setting item.  
Used to change and apply setting values; or to execute/cancel Forced Zero and tare adjustment.  
Note: Refer to the operating manual for details on each function.  
COMMUNICATION CABLE CONNECTIONS  
R2K-1  
RS-485  
RS-485  
47Dx  
T1  
47Dx  
T1  
T1  
T2  
T3  
T4  
RS-232-C  
T2  
T2  
1
1
*
*
T3  
T3  
T4  
T4  
2
*
FG  
*1. Internal terminating resistor is used when the device is at the end of a transmission line.  
*2. Install shield cables to all sections and ground them at single point.  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 5/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
TOP VIEW  
95 (3.74)  
FRONT VIEW  
SIDE VIEW  
103 (4.06)  
96 (3.78)  
98.5 (3.88)  
86 (3.39)  
12.5 (.49)  
2 (.08)  
REAR VIEW  
10–M3 SCREW  
TERMINAL  
20–M3 SCREW  
TERMINAL  
• Alarm Output, RS-485/Modbus  
• No Options  
6.6 (.26)  
2–M3 SCREW  
4–M3 SCREW  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
20  
11  
12  
13  
14  
15  
16  
17  
18  
19  
91.5 (3.60)  
BCD Output, Event Trigger Input, Alarm Output (Photo MOSFET Relay)  
10–M3 SCREW  
TERMINAL  
2–M3 SCREW  
1
2
3
4
5
6
7
8
9
10  
1B  
1A  
25B  
25A  
11 12 13 14 15 16  
EURO TYPE  
50-pin CONNECTOR  
CONNECTOR TERMINAL  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 6/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
MOUNTING REQUIREMENTS unit: mm  
92 +00.8  
min. 120  
Panel thickness: 1.6 to 8.0 mm  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 7/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
REAR TERMINAL ASSIGNMENTS  
TERMINAL A  
1
2
3
4
5
6
7
8
9
10  
20  
1
2
3
4
5
6
7
8
9
10  
TERMINAL D  
11  
12  
13  
14  
15  
16  
17  
18  
19  
TERMINAL C  
TERMINAL B  
1B  
1A  
25B  
25A  
11 12 13 14 15 16  
TERMINAL A : BASIC  
Isolation  
V1/I1  
V2/I2  
V3/I3  
+
1
2
3
4
5
6
Output  
Driver  
+
7
8
9
DC OUTPUT  
+
+
A/D  
Converter  
INPUT  
Digital  
Computation  
U(+)  
Display /  
Setting  
POWER  
COM –  
+
10 V(–)  
Excitation  
Supply  
Infrared  
Interface  
EXCITATION  
Note: The section enclosed by broken line is only with DC output option.  
• Input Terminal Assignments  
INPUT CODE: 1  
INPUT CODE: 2  
MEASURING  
RANGE  
MEASURING  
TYPE ID  
INPUT  
TERMINALS  
INPUT  
TERMINALS  
TYPE ID  
RANGE  
1 – 5V  
3 – 4  
4 – 20mA  
3 – 4  
3 – 4  
2 – 4  
1 – 4  
5V  
3 – 4  
2 – 4  
1 – 4  
0 – 20mA  
20mA  
20V  
200V  
200mA  
• Excitation Supply Connection Examples  
+12V Sensor Excitation  
Isolate between the sensor output and the excitation supply.  
+24V Two-wire Transmitter Excitation  
For use with a smart transmitter (e.g. HART), choose ‘DC voltage input’  
and ‘two-wire transmitter excitation’ when ordering, and then connect  
as shown below.  
+ V1/I1  
+ V2/I2  
+ V3/I3  
COM  
+
1
2
3
4
5
6
Non-smart transmitters are also usable.  
Sensor  
1
resistor*  
+
COM  
+
+ V3  
3
4
5
6
INPUT  
1 – 5V  
sensor output  
250Ω  
Smart Transmitter  
or  
Two-wire Transmitter  
+
COM  
sensor excitation  
4 – 20mA DC  
+12V  
+24V  
Unless the sensor output does not force minus direction  
such as 0 to 5 V or 4 to 20 mA, the configuration as shown  
below is possible. It is not available except measurement  
range 1 to 5 V, 5 V, 4 to 20 mA or 0 to 20 mA.  
*1. Resistor module (model: REM2-250) is provided separately.  
Attach the REM2 to the terminals 3 – 4 as shown below.  
1
2
3
4
5
Recommended ring tongue terminal  
R1.25-3  
Terminals with insulation sleeve do not fit.  
Applicable wire wize 0.3 to 1.25 mm2  
Sensor  
+
+
+ V3/I3  
COM  
+
3
4
5
6
3 max  
4 min  
REM2
sensor output  
11  
15  
3.2 dia.  
sensor excitation  
+12V  
12 max  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 8/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
TERMINAL B  
• Alarm Output : N.O. contact, 4 points  
• Alarm Output : SPDT contact, 2 points  
Ry  
11  
11  
12  
13  
14  
Ry  
15 HHa  
16 Ha  
15 Ha(NO)  
16 Hb(NC)  
Ry  
HH OUTPUT  
L OUTPUT  
12  
13  
14  
H OUTPUT  
L OUTPUT  
H OUTPUT  
Digital  
Computation  
Digital  
Computation  
17 Hc, HHc  
17 Hc(COM  
18 La(NO)  
19 Lb(NC)  
)
Ry  
Ry  
Ry  
18 La  
19 LLa  
LL OUTPUT  
20 Lc, LLc  
20 Lc(COM  
)
Relay Protection  
• AC Powered  
• RS-485 / Modbus RTU  
Inductive  
Load (Coil)  
Isolation  
15  
16  
17  
18  
19  
20  
Shielded Twisted-pair Cable  
Digital  
Computation  
Output  
Driver  
Varistor or  
CR Circuit  
+
T1  
T2  
T3  
T4  
11  
12  
13  
14  
To other  
Modbus devices  
LOAD  
Term.  
Resist.  
U
Jumper *1  
• DC Powered  
Inductive  
Load (Coil)  
Diode, Varistor or  
CR Circuit  
LOAD  
*1. When the device is located at the end of a transmission line via twisted-pair cable  
(when there is no cross-wiring), close across the terminal 12 – 13 with a leadwire.  
When the device is not at the end, no shortcircuit wire is required.  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 9/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
TERMINAL C : BCD OUTPUT  
• Connector Pin Assignment  
Isolation  
PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT  
Digital  
Computation  
BCD  
Output  
1B  
1A  
25B  
25A  
1A  
2A  
COM  
COM  
LL  
1B  
2B  
Do 38  
COM  
Do 34  
COM  
Do 32  
COM  
Do 31  
COM  
Do 28  
COM  
Do 24  
COM  
Do 22  
COM  
Do 21  
Do 68  
Do 18  
Do 64  
Do 14  
Do 62  
Do 12  
Do 61  
Do 11  
COM  
COM  
3A  
3B  
4A  
L
4B  
5A  
PASS  
H
5B  
6A  
6B  
7A  
HH  
7B  
8A  
POL  
8B  
9A  
RESET  
HOLD  
MIN_REQ  
MAX_REQ  
REQ  
9B  
10A  
11A  
12A  
13A  
14A  
15A  
16A  
17A  
18A  
19A  
20A  
21A  
22A  
23A  
24A  
25A  
10B  
11B  
12B  
13B  
14B  
15B  
16B  
17B  
18B  
19B  
20B  
21B  
22B  
23B  
24B  
25B  
• Open collector  
COM  
RUN  
Output  
DAV  
OVF  
Do 58  
Do 54  
Do 52  
Do 51  
Do 48  
Do 44  
Do 42  
Do 41  
• Output Logic  
Voltage Level at ON  
Output Logic  
Positive  
Hi  
Lo  
Negative  
• Connected to a PLC (example)  
• Connected to a digital display (example)  
Digital Panel Meter  
+24 V  
DC Power Supply  
COM  
+6 V  
0 V  
Digital Panel Meter  
+6 V  
shortcircuit  
2 kΩ  
REQ  
PLC Transistor Output Unit  
1.5 kΩ  
2 kΩ  
REQ  
OUT  
OUT  
2 kΩ  
1.5 kΩ  
9A  
RESET  
1.5 kΩ  
2 kΩ  
9A  
RESET  
COM  
Do11  
Do12  
Do14  
Do18  
1.5 kΩ  
COM  
(0 V)  
23B  
21B  
19B  
17B  
24 V DC  
1st LSD  
BCD Input Module  
COM  
Do11  
Do12  
Do14  
Do18  
COM  
IN  
23B  
21B  
19B  
17B  
6th LSD  
2nd LSD  
16A  
15A  
8A  
DAV  
RUN  
POL  
IN  
1st LSD  
IN  
IN  
(polarity +, –)  
16A  
15A  
8A  
DAV  
RUN  
POL  
IN  
IN  
IN  
Digital Display  
Use Special cable (model: HDR40) and Connector Terminal Block  
(model: CNT).  
Refer to the cable’s data sheet for pin assignments.  
(polarity +, –)  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 10/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
TERMINAL D  
• Alarm Output : Photo MOSFET Relay N.O. contact, 4 points  
• Event Trigger Input  
Isolation  
Ry  
Digital  
Computation  
11 HHa  
11 TIMING  
12 S-TMR  
Ry  
HH OUTPUT  
12 Ha  
H OUTPUT  
Digital  
Computation  
13 Hc, HHc  
13 HOLD  
14 RESET  
15 ZERO  
16 COM  
Digital  
Computation  
Ry  
Ry  
14 La  
L OUTPUT  
15 LLa  
LL OUTPUT  
16 Lc, LLc  
Connection Example  
TIMING : 11  
S-TMR : 12  
HOLD : 13  
RESET : 14  
ZERO : 15  
+6 V  
2 kΩ  
1.5 kΩ  
NPN  
dry  
contact  
open  
collector  
16  
COM  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 11/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
BCD OUTPUT TIMING CHART  
VIEWING ANGLE  
Request signals (REQ, MAX_REQ, MIN_REQ) from an external  
device (e.g. PLC) are required in order to read out BCD data.  
All signals in the following charts are in the negative logic  
(ON at LOW signal, as factory set).  
The display is designed to provide the optimal legibility  
when viewed from the angles as shown below.  
• Timing Chart for Continuous Data Output  
REQ  
MAX_REQ Hi  
MIN_REQ  
Lo  
*1  
Hi  
DATA  
DAV  
all data H  
data  
data  
Lo  
Hi  
Lo  
30 ms  
approx.  
40 ms  
24 ms  
40 ms  
24 ms  
64 ms  
64 ms  
Measured data is output every 64 ms while one of REQ signals (REQ,  
MAX_REQ or MIN_REQ) remains ON. For Event trigger modes, the data  
value is the same as the display.  
• Timing Chart for Single Sampling Cycle Data Output  
20 ms or wider (max. 50 ms)  
REQ  
MAX_REQ Hi  
MIN_REQ  
Lo  
*1  
DATA  
Hi  
all data H  
data  
all data H  
Lo  
Hi  
DAV  
Lo  
30 ms  
approx.  
40 ms  
16 ms  
When one of REQ signals (REQ, MAX_REQ or MIN_REQ) is given and  
its width is between 20 and 50 ms, DATA is established and DAV output  
is given in approx. 30 ms from the falling edge of the REQ signal.  
Read in the data to a PLC at the timing of the DAV output signal.  
DAV is turned off in 40 ms. DATA is turned off in 16 ms after that.  
Output is provided via open collector, enabling wired-OR gate configuration  
REQ 1 Hi  
Lo  
Hi  
REQ 2  
Lo  
Hi  
Lo  
Hi  
REQ 3  
*1  
DATA  
1
2
3
Lo  
Hi  
DAV  
Lo  
*2  
*2  
*2  
When DATA output logic is negative, wired-OR connection is available  
for BCD data, POL, OVF, HH, H, P, L and LL signals.  
*1. DATA includes BCD Output, POL, OVF, HH, H, P, L, LL and RUN.  
*2. Wait for at least 20 ms between DAV turning off and the next REQ signal.  
REQ 1  
47Dx  
1
REQ 2  
47Dx  
2
PLC  
REQ 3  
47Dx  
3
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 12/13  
https://www.m-system.co.jp/  
MODEL: 47DV  
SYSTEM CONFIGURATION EXAMPLES  
RS-485 / RS-232-C  
RS-485 / ETHERNET  
RS-232-C  
Ethernet  
RS-232-C/RS-485  
Converter  
(model: R2K-1 or LK1)  
Communication Adaptor  
(model: 72EM2-M4)  
ETHERNET  
RS-485  
RUN  
SEND  
FIELD  
CNFG  
Lightning Surge Protector  
for RS-485/422  
(model: MD74R or MDP-4R) *1  
Lightning Surge Protector  
for RS-485/422  
(model: MD74R or MDP-4R) *1  
RS-485 (Modbus RTU)  
RS-485 (Modbus RTU)  
Lightning Surge  
Protector for  
RS-485/422  
(model: MD74R  
or MDP-4R) *1  
Lightning Surge  
Protector for  
RS-485/422  
(model: MD74R  
or MDP-4R) *1  
M
M
FZ  
TZ  
M
Mi  
FZ  
TZ  
Max  
ax  
in  
ax  
n
M
M
FZ  
TZ  
M
Mi  
FZ  
TZ  
M
M
FZ  
TZ  
ax  
in  
ax  
n
ax  
in  
M
in  
FZ  
TZ  
Hld  
Hld  
Hld  
TG  
NG  
TG  
TG  
Hld  
Hld  
Hld  
NG  
NG  
TG  
TG  
TG  
Zr  
o
Zr  
o
Zr  
o
NG  
NG  
NG  
Spn  
Sp  
Spn  
Tc  
n
Zr  
Zr  
Zr  
Tc  
Tc  
o
o
o
Sp  
n
h
h
h
Spn  
Sp  
n
Tc  
Tc  
Tc  
h
h
h
Digital Panel Meter  
(model: 47Dx)  
Digital Panel Meter  
(model: 47Dx)  
*1. Insert lightning surge protectors recommended in this example if necessary.  
Specifications are subject to change without notice.  
47DV SPECIFICATIONS  
ES-9501 Rev.17 Page 13/13  
https://www.m-system.co.jp/  

47DV-1011-R 相关器件

型号 制造商 描述 价格 文档
47DV-1011-R/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1012-M2 MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1012-M2/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1012-P MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1012-P/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1012-R MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1012-R/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1013-M2 MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1013-M2/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47DV-1013-P MSYSTEM Digital Panel Meters 47 Series 获取价格

47DV-1011-R 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8