47LAC-162YR-R

更新时间:2024-10-29 22:40:50
品牌:MSYSTEM
描述:Digital Panel Meters 47 Series

47LAC-162YR-R 概述

Digital Panel Meters 47 Series

47LAC-162YR-R 数据手册

通过下载47LAC-162YR-R数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: 47LAC  
2: SPDT relay contact, 2 points  
Digital Panel Meters 47 Series  
[4] DISPLAY COLOR  
R: Red  
AC INPUT DIGITAL PANEL METER  
(4½ digit, LED display type, true RMS sensing)  
Functions & Features  
YR: Orange  
G: Green  
• 4 1/2 digit AC input digital panel meter  
• 1/8 DIN size  
BG: Bluegreen  
B: Blue  
• Moving average function to suppress the display flickering  
• Max. and Min. value display  
W: White  
• IP66 front panel  
• Separable terminal block  
[5] POWER INPUT  
AC Power  
• Rear terminal cover for safety strapped to the meter  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)  
DC Power  
96 (3.78)  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
H
H
H
48  
(1.89)  
P
L
L
L
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
Zr  
o
Sp  
n
D/P  
Tc  
h
Fnc  
Mi  
n
Max  
Ma  
x/M  
in  
A
la  
rm  
/
S
ca  
le  
/
S
hif  
t
U
p
98.5 (3.88)  
[6] OPTIONS  
blank: none  
mm (inch)  
/Q: With options (specify the specification)  
MODEL: 47LAC-[1][2][3][4]-[5][6]  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
Moving parts and indicators are not coated.  
/C01: Silicone coating  
ORDERING INFORMATION  
• Code number: 47LAC-[1][2][3][4]-[5][6]  
Specify a code from below for each of [1] through [6].  
(e.g. 47LAC-101G-M2/Q)  
/C02: Polyurethane coating  
/C03: Rubber coating  
• Specify the specification for option code /Q  
(e.g. /C01/S01/SET)  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
EX-FACTORY SETTING  
[1] INPUT  
1: AC current  
2: AC voltage  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-9511)  
GENERAL SPECIFICATIONS  
Construction: Panel flush mounting  
Degree of protection: IP66; applicable to the front of the  
panel meter mounted according to the specified panel  
cutout  
[2] DC OUTPUT  
0: Without  
Current  
A: 4 – 20 mA DC (Load resistance 550 Ω max.)  
D: 0 – 20 mA DC (Load resistance 550 Ω max.)  
Voltage  
Connection: M3 separable screw terminal (torque 0.6 N·m)  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
Housing material: Flame-resistant resin (gray)  
Isolation: Input to DC output to HH output or H output to  
L output or LL output to power  
Input waveform  
RMS sensing: Up to 15 % of 3rd harmonic content  
Setting: (Front button)  
[3] ALARM OUTPUT  
0: None  
• Scaled range  
1: N.O. relay contact, 4 points  
47LAC SPECIFICATIONS  
ES-9511 Rev.13 Page 1/7  
https://www.m-system.co.jp/  
MODEL: 47LAC  
• Input type  
INPUT CODE: 1  
• Alarm setpoint  
TYPE  
MEASURING OPERATIONAL  
INPUT  
IMPEDANCE  
100 Ω  
• Hysteresis (deadband)  
• Moving average  
IND  
A2  
RANGE  
RANGE  
0 – 2 mA  
0 – 20 mA  
0 – 200 mA  
0 – 2.2 mA  
0 – 22 mA  
0 – 220 mA  
A20  
A200  
1 Ω  
1 Ω  
• Others  
(Refer to the instruction manual for details)  
Read rate: 40 times/sec. (25 msec.)  
Averaging: None or moving average  
Lockout setting: Prohibiting certain operations; protecting  
settings  
INPUT CODE: 2  
TYPE  
IND  
MEASURING OPERATIONAL  
INPUT  
IMPEDANCE  
≥ 100 kΩ  
RANGE  
0 – 0.1 V  
0 – 1 V  
RANGE  
0 – 0.11 V  
0 – 1.1 V  
0 – 11 V  
V0.1  
V1  
≥ 100 kΩ  
≥ 1 MΩ  
V10  
0 – 10 V  
DISPLAY  
Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED  
Display range: -19999 to 19999  
OUTPUT SPECIFICATIONS  
■ DC Output  
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none  
Zero indication: Higher-digit zeros are suppressed.  
Over-range indication: ‘-19999’ or ‘19999’ blinking for  
display values out of the scaled range.  
‘S.ERR’ and ‘Max’ blinking when the input signal is out of  
the usable range.  
• DC Current  
Operational range: -5 – +105 %  
• DC Voltage  
Operational range: -5 – +105 %  
Alarm Output: Relay contact  
Rated load: 250 V AC @ 3 A (cos ø = 1)  
30 V DC @ 3 A (resistive load)  
Alarm status indication  
LL indicator: Green turns on when the LL alarm is tripped.  
L indicator: Green turns on when the L alarm is tripped.  
H indicator: Red turns on when the H alarm is tripped.  
HH indicator: Red turns on when the HH alarm is tripped.  
P indicator: Amber turns on when none of the other alarms  
is tripped.  
Maximum switching voltage: 250 V AC, 30 V DC  
Maximum switching power: 750 VA, 90 W (resistive load)  
Minimum load: 5 V DC @ 10 mA  
Mechanical life: ≥ 5 × 10 cycles (rate 180 cycles/min.)  
6
Note: Only ‘P’ turns on with no-alarm-output type. ‘LL’ or  
‘HH’ does not turn on with dual-alarm-output type.  
All setpoints can be independently set either for Hi or Lo  
alarm trip.  
INSTALLATION  
Power consumption  
AC: Approx. 6.5VA  
DC: Approx. 3 W  
Function indicators:  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Panel flush mounting  
Zro, Spn, D/P, Tch, Fnc, Min, Max  
Display mode status and operation status, amber ON or  
blink  
Weight: 300 g (0.66 lb)  
Engineering unit indication: Sticker label attached  
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,  
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,  
cm, mm, m, m/sec, mm/min, cm/min, m/min,  
PERFORMANCE in percentage of max. span  
Accuracy  
m/h, m/s  
2
, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m  
3
, m  
3
/sec,  
Display: ±0.5 % ±20 digits (input 5 – 100 %)  
Output: ±0.1 % (DC output = display + output)  
Temp. coefficient: ±0.05 %/°C (±0.03 %/°F)  
Input resolution: Max. 16 bits  
m3/min, m  
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,  
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,  
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.  
Output resolution: Max. 14 bits  
Response time: ≤ 0.5 sec.  
INPUT SPECIFICATIONS  
Frequency: 40 Hz – 1 kHz  
(alarm output: 0 – 100 % at 90 % setpoint)  
≤ 0.5 sec. (DC output: 0 – 90 %)  
Overload capacity: 200 % of the selected measuring range  
Default value  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @ 1 minute (input to DC  
output to HH output or H output to L output or LL output to  
power to ground)  
AC current input: Measuring range 0 – 200 mA  
AC voltage input: Measuring range 0 – 10 V  
47LAC SPECIFICATIONS  
ES-9511 Rev.13 Page 2/7  
https://www.m-system.co.jp/  
MODEL: 47LAC  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
Measurement Category II (alarm output)  
Installation Category II (power)  
Pollution degree 2  
Input or DC output to alarm output to power: Reinforced  
insulation (300 V)  
Input to DC output: Basic insulation (300 V)  
RoHS Directive  
Protection against access to the terminal blocks:  
Finger protection (VDE 0660-514)  
EXTERNAL VIEW  
(1) Main Display  
HH  
H
P
(2) Alarm Indicators  
L
LL  
Zro Spn D/P  
Tch Fnc Min Max  
(3) Function Indicators  
Max/Min  
Alarm/  
Scale/  
Shift  
Up  
(8) Up Button  
(7) Shift Button  
(6) Scale/ Button  
(4) Max/Min Button  
(5) Alarm/ Button  
• COMPONENT IDENTIFICATION  
No. COMPONENT  
(1) Main display  
FUNCTION  
Indicates present values, setting values and status of the unit.  
Indicate alarm status of the input signal.  
(2) Alarm indicators  
(3) Function indicators  
(4) Max/Min button  
Indicate the status in each setting mode.  
Used to switch the main display to show the present values, maximum values or minimum values etc.  
(5)  
Used to con!rm alarm setting value and to move on to the alarm and other setting modes; or to shift through  
setting items in each setting mode.  
Alarm/ button  
(6)  
Used to move on to the scaling and other setting modes; or to shift through setting items in each setting  
mode.  
Scale/ button  
(7) Shift button  
(8) Up button  
Used to move on to the setting standby status of each setting mode and shift through display digits in each  
setting mode.  
Used to execute/cancel Forced Zero or to select setting values in each setting mode.  
Note: Refer to the operating manual for details on each function.  
47LAC SPECIFICATIONS  
ES-9511 Rev.13 Page 3/7  
https://www.m-system.co.jp/  
MODEL: 47LAC  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
TOP VIEW  
95 (3.74)  
FRONT VIEW  
SIDE VIEW  
103 (4.06)  
96 (3.78)  
98.5 (3.88)  
86 (3.39)  
12.5 (.49)  
2 (.08)  
REAR VIEW  
• Alarm Output  
• No Alarm Output  
10–M3 SCREW  
TERMINAL  
20–M3 SCREW  
TERMINAL  
6.6 (.26)  
2–M3 SCREW  
4–M3 SCREW  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
20  
11  
12  
13  
14  
15  
16  
17  
18  
19  
91.5 (3.60)  
47LAC SPECIFICATIONS  
ES-9511 Rev.13 Page 4/7  
https://www.m-system.co.jp/  
MODEL: 47LAC  
MOUNTING REQUIREMENTS unit: mm  
92 +00.8  
min. 120  
Panel thickness: 1.6 to 8.0 mm  
47LAC SPECIFICATIONS  
ES-9511 Rev.13 Page 5/7  
https://www.m-system.co.jp/  
MODEL: 47LAC  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
ALARM OUTPUT CODE 0: No alarm output  
Isolation  
Output  
Driver  
H
L
+
1
2
3
7
8
9
DC OUTPUT  
POWER  
A/D  
Converter  
Digital  
Computation  
INPUT  
COM  
U(+)  
4
5
6
10 V(–)  
Display /  
Setting  
ALARM OUTPUT CODE 1: N.O. contact, 4 points  
Isolation  
Output  
Driver  
H
L
+
1
2
3
7
8
DC OUTPUT  
A/D  
Converter  
INPUT  
Ry  
Ry  
COM  
Digital  
Computation  
15 HHa  
16 Ha  
4
5
HH OUTPUT  
H OUTPUT  
Display /  
Setting  
17 Hc, HHc  
6
Ry  
Ry  
11  
12  
13  
14  
18 La  
L OUTPUT  
19 LLa  
LL OUTPUT  
20 Lc, LLc  
U(+)  
10 V(–)  
9
POWER  
ALARM OUTPUT CODE 2: SPDT contact, 2 points  
Isolation  
Output  
Driver  
H
L
+
1
2
3
7
8
DC OUTPUT  
A/D  
Converter  
INPUT  
Ry  
COM  
Digital  
Computation  
15 Ha(NO)  
16 Hb(NC)  
4
5
Display /  
Setting  
H OUTPUT  
17 Hc(COM  
18 La(NO)  
19 Lb(NC)  
)
6
Ry  
11  
12  
13  
14  
L OUTPUT  
20 Lc(COM  
U(+)  
10 V(–)  
)
9
POWER  
Note: The section enclosed by broken line is only with DC output option.  
Relay Protection  
• AC Powered  
• DC Powered  
Inductive  
Load (Coil)  
Inductive  
Load (Coil)  
Diode, Varistor or  
CR Circuit  
Varistor or  
CR Circuit  
LOAD  
LOAD  
U
47LAC SPECIFICATIONS  
ES-9511 Rev.13 Page 6/7  
https://www.m-system.co.jp/  
MODEL: 47LAC  
• Input Terminal Assignments  
INPUT TYPE  
(indicator)  
MEASURING  
RANGE  
INPUT  
TERMINALS  
A2  
0 – 2mA  
2 – 3  
1 – 3  
A20  
A200  
0 – 20mA  
0 – 200mA  
V0.1  
V1  
0 – 0.1V  
0 – 1V  
2 – 3  
1 – 3  
V10  
0 – 10V  
Specifications are subject to change without notice.  
47LAC SPECIFICATIONS  
ES-9511 Rev.13 Page 7/7  
https://www.m-system.co.jp/  

47LAC-162YR-R 相关器件

型号 制造商 描述 价格 文档
47LAC-162YR-R/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0B-M2 MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0B-M2/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0B-P MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0B-P/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0B-R MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0B-R/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0BG-M2 MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0BG-M2/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LAC-1A0BG-P MSYSTEM Digital Panel Meters 47 Series 获取价格

47LAC-162YR-R 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8