47LHZ-103B-R/Q

更新时间:2024-11-08 22:50:59
品牌:MSYSTEM
描述:Digital Panel Meters 47 Series

47LHZ-103B-R/Q 概述

Digital Panel Meters 47 Series

47LHZ-103B-R/Q 数据手册

通过下载47LHZ-103B-R/Q数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: 47LHZ  
2: SPDT relay contact, 2 points  
Digital Panel Meters 47 Series  
[3] DISPLAY COLOR  
R: Red  
FREQUENCY INPUT DIGITAL PANEL METER  
(4½ digit, LED display type)  
YR: Orange  
G: Green  
Functions & Features  
• 4½ digit digital panel meter  
• Measures line frequency deviation of a heavycurrent  
power system  
BG: Bluegreen  
B: Blue  
W: White  
• 1/8 DIN size  
• Max. and Min. value display  
• IP66 front panel  
[4] POWER INPUT  
AC Power  
• Separable terminal block  
• Rear terminal cover for safety strapped to the meter  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)  
DC Power  
R: 24 V DC  
96 (3.78)  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
H
H
H
48  
(1.89)  
P
L
L
L
Zr  
o
Sp  
n
D/P  
Tc  
h
Fnc  
Mi  
n
Max  
Ma  
x/M  
in  
A
la  
rm  
/
S
ca  
le  
/
S
[5] OPTIONS  
hif  
t
U
p
98.5 (3.88)  
blank: none  
mm (inch)  
/Q: With options (specify the specification)  
MODEL: 47LHZ-1[1][2][3]-[4][5]  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
Moving parts and indicators are not coated.  
/C01: Silicone coating  
ORDERING INFORMATION  
• Code number: 47LHZ-1[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. 47LHZ-101G-M2/Q)  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
• Specify the specification for option code /Q  
(e.g. /C01/S01/SET)  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-9517)  
INPUT  
1: Frequency input  
GENERAL SPECIFICATIONS  
Construction: Panel flush mounting  
Degree of protection: IP66; applicable to the front of the  
panel meter mounted according to the specified panel  
cutout  
[1] DC OUTPUT  
0: Without  
Current  
A: 4 – 20 mA DC (Load resistance 550 Ω max.)  
D: 0 – 20 mA DC (Load resistance 550 Ω max.)  
Voltage  
Connection: M3 separable screw terminal (torque 0.6 N·m)  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
Housing material: Flame-resistant resin (gray)  
Isolation: Input to DC output to HH output or H output to  
L output or LL output to power  
Input waveform: Up to 15 % of 3rd harmonic content  
Setting: (Front button)  
[2] ALARM OUTPUT  
0: None  
• Scaled range  
• Input type  
1: N.O. relay contact, 4 points  
47LHZ SPECIFICATIONS  
ES-9517 Rev.11 Page 1/7  
https://www.m-system.co.jp/  
MODEL: 47LHZ  
• Alarm setpoint  
OUTPUT SPECIFICATIONS  
■ DC Output  
• Hysteresis (deadband)  
• Others  
• DC Current  
(Refer to the instruction manual for details)  
Lockout setting: Prohibiting certain operations; protecting  
settings  
Operational range: -5 – +105 %  
• DC Voltage  
Operational range: -5 – +105 %  
Alarm Output: Relay contact  
Rated load: 250 V AC @ 3 A (cos ø = 1)  
30 V DC @ 3 A (resistive load)  
Maximum switching voltage: 250 V AC, 30 V DC  
Maximum switching power: 750 VA, 90 W (resistive load)  
Minimum load: 5 V DC @ 10 mA  
DISPLAY  
Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED  
Display range: -19999 to 19999  
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none  
Zero indication: Higher-digit zeros are suppressed.  
Over-range indication: ‘-19999’ or ‘19999’ blinking for  
display values out of the display range.  
‘S.ERR’ and ‘Min’ or ‘Max’ blinking when the input signal is  
out of the usable range.  
Mechanical life: ≥ 5 × 10 cycles (rate 180 cycles/min.)  
6
INSTALLATION  
Power consumption  
AC: Approx. 6.5VA  
DC: Approx. 3 W  
Alarm status indication  
LL indicator: Green turns on when the LL alarm is tripped.  
L indicator: Green turns on when the L alarm is tripped.  
H indicator: Red turns on when the H alarm is tripped.  
HH indicator: Red turns on when the HH alarm is tripped.  
P indicator: Amber turns on when none of the other alarms  
is tripped.  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Panel flush mounting  
Weight: 300 g (0.66 lb)  
Note: Only ‘P’ turns on with no-alarm-output type. ‘LL’ or  
‘HH’ does not turn on with dual-alarm-output type.  
All setpoints can be independently set either for Hi or Lo  
alarm trip.  
PERFORMANCE in percentage of max. span  
Accuracy  
Display: ±0.1 Hz; ±1 Hz at 70 Hz or more (input 50 – 300  
V)  
Function indicators:  
Output: ±0.1 % (DC output = display + output)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Input resolution: Max. 0.01 Hz  
Zro, Spn, D/P, Tch, Fnc, Min, Max  
Display mode status and operation status, amber ON or  
blink  
Output resolution: Max. 14 bits  
Engineering unit indication: Sticker label attached  
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,  
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,  
cm, mm, m, m/sec, mm/min, cm/min, m/min,  
Response time: ≤0.5 second except for 45 Hz or less  
(alarm output: 0 – 100 % at 90 % setpoint)  
≤0.5 second except for 45 Hz or less  
(DC output: 0 – 90 %)  
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @ 1 minute (input to DC  
output to HH output or H output to L output or LL output to  
power to ground)  
m
3
/min, m  
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,  
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,  
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.  
INPUT SPECIFICATIONS  
Input voltage: Max. 300 V (conformance range 50 – 300 V)  
Overload capacity: 450 V for 10 seconds, 360 V continuous  
Defautlt measuring range: 45 – 65 Hz  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
TYPE MEASURING OPERATIONAL  
INPUT  
EMI EN 61000-6-4  
IND  
H50  
H60  
H55  
RANGE  
RANGE  
BURDEN  
EMS EN 61000-6-2  
45 – 55 Hz  
55 – 65 Hz  
45 – 65 Hz  
40 – 60 Hz  
50 – 70 Hz  
40 – 70 Hz  
≤0.5VA  
≤0.5VA  
≤0.5VA  
≤0.5VA  
≤0.5VA  
Low Voltage Directive  
EN 61010-1  
Measurement Category III (input)  
Measurement Category II (alarm output)  
Installation Category II (power)  
H400 350 – 450 Hz 300 – 500 Hz  
HF 10 – 500 Hz 5 – 600 Hz  
47LHZ SPECIFICATIONS  
ES-9517 Rev.11 Page 2/7  
https://www.m-system.co.jp/  
MODEL: 47LHZ  
Pollution Degree 2  
Input or DC output to alarm output to power: Reinforced  
insulation (300 V)  
Input to DC output: Basic insulation (300 V)  
RoHS Directive  
Protection against access to the terminal blocks:  
Finger protection (VDE 0660-514)  
EXTERNAL VIEW  
(1) Main Display  
HH  
H
P
(2) Alarm Indicators  
L
LL  
Zro Spn D/P  
Tch Fnc Min Max  
(3) Function Indicators  
Max/Min  
Alarm/  
Scale/  
Shift  
Up  
(8) Up Button  
(7) Shift Button  
(6) Scale/ Button  
(4) Max/Min Button  
(5) Alarm/ Button  
• COMPONENT IDENTIFICATION  
No. COMPONENT  
(1) Main display  
FUNCTION  
Indicates present values, setting values and status of the unit.  
Indicate alarm status of the input signal.  
(2) Alarm indicators  
(3) Function indicators  
(4) Max/Min button  
Indicate the status in each setting mode.  
Used to switch the main display to show the present values, maximum values or minimum values etc.  
(5)  
Used to con!rm alarm setting value and to move on to the alarm and other setting modes; or to shift through  
setting items in each setting mode.  
Alarm/ button  
(6)  
Used to move on to the scaling and other setting modes; or to shift through setting items in each setting  
mode.  
Scale/ button  
(7) Shift button  
(8) Up button  
Used to move on to the setting standby status of each setting mode and shift through display digits in each  
setting mode.  
Used to select setting values in each setting mode.  
Note: Refer to the operating manual for details on each function.  
47LHZ SPECIFICATIONS  
ES-9517 Rev.11 Page 3/7  
https://www.m-system.co.jp/  
MODEL: 47LHZ  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
TOP VIEW  
95 (3.74)  
FRONT VIEW  
SIDE VIEW  
103 (4.06)  
96 (3.78)  
98.5 (3.88)  
86 (3.39)  
12.5 (.49)  
2 (.08)  
REAR VIEW  
• Alarm Output  
• No Alarm Output  
10–M3 SCREW  
TERMINAL  
20–M3 SCREW  
TERMINAL  
6.6 (.26)  
2–M3 SCREW  
4–M3 SCREW  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
20  
11  
12  
13  
14  
15  
16  
17  
18  
19  
91.5 (3.60)  
47LHZ SPECIFICATIONS  
ES-9517 Rev.11 Page 4/7  
https://www.m-system.co.jp/  
MODEL: 47LHZ  
MOUNTING REQUIREMENTS unit: mm  
92 +00.8  
min. 120  
Panel thickness: 1.6 to 8.0 mm  
47LHZ SPECIFICATIONS  
ES-9517 Rev.11 Page 5/7  
https://www.m-system.co.jp/  
MODEL: 47LHZ  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
ALARM OUTPUT CODE 0: No alarm output  
SOURCE  
Isolation  
VT  
FUSE  
U
V
u
v
Output  
Driver  
+
1
3
7
8
9
Frequency  
Converter  
DC OUTPUT  
Digital  
Computation  
LOAD  
2
4
5
6
U(+)  
Display /  
Setting  
POWER  
10 V(–)  
ALARM OUTPUT CODE 1: N.O. contact, 4 points  
SOURCE  
Isolation  
VT  
FUSE  
U
V
u
v
Output  
Driver  
+
1
3
7
8
Frequency  
Converter  
DC OUTPUT  
Ry  
Ry  
LOAD  
2
4
Digital  
Computation  
Display /  
Setting  
15 HHa  
16 Ha  
HH OUTPUT  
H OUTPUT  
5
6
17 Hc, HHc  
Ry  
Ry  
11  
12  
13  
14  
18 La  
L OUTPUT  
19 LLa  
LL OUTPUT  
20 Lc, LLc  
U(+)  
10 V(–)  
9
POWER  
ALARM OUTPUT CODE 2: SPDT contact, 2 points  
SOURCE  
Isolation  
VT  
FUSE  
U
V
u
v
Output  
Driver  
+
1
3
7
8
Frequency  
Converter  
DC OUTPUT  
Ry  
LOAD  
2
4
Digital  
Computation  
Display /  
Setting  
15 Ha(NO)  
16 Hb(NC)  
H OUTPUT  
L OUTPUT  
5
17 Hc(COM  
18 La(NO)  
19 Lb(NC)  
)
6
Ry  
11  
12  
13  
14  
20 Lc(COM  
U(+)  
10 V(–)  
)
9
POWER  
Note: The section enclosed by broken line is only with DC output option.  
Relay Protection  
• AC Powered  
• DC Powered  
Inductive  
Load (Coil)  
Inductive  
Load (Coil)  
Diode, Varistor or  
CR Circuit  
Varistor or  
CR Circuit  
LOAD  
LOAD  
U
47LHZ SPECIFICATIONS  
ES-9517 Rev.11 Page 6/7  
https://www.m-system.co.jp/  
MODEL: 47LHZ  
Specifications are subject to change without notice.  
47LHZ SPECIFICATIONS  
ES-9517 Rev.11 Page 7/7  
https://www.m-system.co.jp/  

47LHZ-103B-R/Q 相关器件

型号 制造商 描述 价格 文档
47LHZ-103BG-M2 MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103BG-M2/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103BG-P MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103BG-P/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103BG-R MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103BG-R/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103G-M2 MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103G-M2/Q MSYSTEM Digital Panel Meters 47 Series 获取价格
47LHZ-103G-P MSYSTEM Digital Panel Meters 47 Series 获取价格