47LLC-S363B-M2 概述
Digital Panel Meters 47 Series
47LLC-S363B-M2 数据手册
通过下载47LLC-S363B-M2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: 47LLC
Digital Panel Meters 47 Series
[3] ALARM OUTPUT
0: None
1: N.O. relay contact, 4 points
2: SPDT relay contact, 2 points
3: Photo MOSFET relay, N.O., 4 points
STRAIN GAUGE INPUT DIGITAL PANEL METER
(4½ digit, LED display type)
Functions & Features
• 4½ digit strain gauge input digital panel meter
• 1/8 DIN size
[4] DISPLAY COLOR
R: Red
• Moving average function to suppress the display flickering
• Scaling, tare adjustment, low-end cutout
• Max. and Min. value display
YR: Orange
G: Green
• Safety terminal cover tethered to the device with a strap
• IP66 front panel
BG: Bluegreen
B: Blue
• Separable terminal block
W: White
[5] POWER INPUT
96 (3.78)
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
H
H
DC Power
H
48
(1.89)
P
L
L
L
Zr
o
Sp
n
D/P
R: 24 V DC
Tc
h
Fnc
Mi
n
Max
Ma
x/M
in
A
la
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
rm
/
S
ca
le
/
S
hif
t
U
p
98.5 (3.88)
mm (inch)
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
[6] OPTIONS
MODEL: 47LLC-[1][2][3][4]-[5][6]
blank: none
/Q: With options (specify the specification)
ORDERING INFORMATION
• Code number: 47LLC-[1][2][3][4]-[5][6]
Specify a code from below for each of [1] through [6].
(e.g. 47LLC-S101G-M2/Q)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
/C02: Polyurethane coating
/C03: Rubber coating
[1] INPUT STRAIN GAUGE
S1: 0.0 – 1.0 mV/V
TERMINAL SCREW MATERIAL
/S01: Stainless steel
S2: 0.0 – 3.0 mV/V
EX-FACTORY SETTING
S3: 0.0 – 10.0 mV/V
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9505)
S4: 0.0 – 30.0 mV/V
[2] DC OUTPUT
0: Without
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Current
Degree of protection: IP66; applicable to the front of the
panel meter mounted according to the specified panel
cutout
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
Voltage
Connection: M3 separable screw terminal (torque 0.6 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
Housing material: Flame-resistant resin (gray)
Isolation: Strain gauge input or excitation or contact input or
SG to DC output to HH output or H output to L output or LL
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 1/7
http://www.m-system.co.jp/
MODEL: 47LLC
output to power
INPUT SPECIFICATIONS
■ Strain Gauge Input
Excitation: 2.5 V, 5 V, 7.5 V or 10 V selectable (front)
Tare adjustment: Via the front button control or by the
external contact input
• Strain Gauge: Refer to the next table
• Excitation: 2.5 V, 5 V, 7.5 V or 10 V selectable
Maximum current: 120 mA
Setting: (Front button)
• Scaled range
Load resistance: ≥ 85 Ω
• Alarm setpoint
Default setting: 2.5 V
• Hysteresis (deadband)
■ Tare Command Input: TTL level (5V-CMOS level), open
collector or dry contact
• Moving average
• Others
(saturation voltage ≤ 1 V, sink current 0.5 mA)
(Refer to the instruction manual for details)
Read rate: 40 times/sec. (25 msec.)
Averaging: None or moving average
Lockout setting: Prohibiting certain operations; protecting
settings
TYPE
S1
STRAIN GAUGE RATING
0.0 – 1.0mV/V
ZERO ADJUSTMENT
-10.00 – +10.00mV
-30.00 – +30.00mV
-100.0 – +100.0mV
-300.0 – +300.0mV
S2
0.0 – 3.0mV/V
S3
0.0 – 10.0mV/V
0.0 – 30.0mV/V
S4
SPAN
INPUT VOLTAGE
-10.00 – +20.00mV
-30.00 – +60.00mV
-100.0 – +200.0mV
-300.0 – +600.0mV
TYPE
S1
1.00 – 10.00mV
3.00 – 30.00mV
10.0 – 100.0mV
30.0 – 300.0mV
DISPLAY
S2
Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED
S3
Display range: -19999 to 19999
S4
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none
Zero indication: Higher-digit zeros are suppressed.
Over-range indication: ‘-19999’ or ‘19999’ blinking for
display values out of the scaled range.
‘S.ERR’ and ‘Max’ blinking when the input signal is out of
the usable range.
Note 1: Choose Type S2 for the strain gauge rating 2.0mV/V with the
excitation voltage 10V.
For detailed information, refer to “Input Scaling Values A/B v.s.
Tare Adjustment” under “PARAMETER LIST” on the instruction manual.
Note 2: Consult factory for use with a compression/tension load cells.
Alarm status indication
OUTPUT SPECIFICATIONS
■ DC Output
LL indicator: Green LED turns on when the LL alarm is
tripped.
• DC Current
L indicator: Green LED turns on when the L alarm is
tripped.
Operational range: -5 – +105 %
• DC Voltage
H indicator: Red LED turns on when the H alarm is tripped.
HH indicator: Red LED turns on when the HH alarm is
tripped.
Operational range: -5 – +105 %
■ Alarm Output
• Relay contact
P indicator: Amber LED turns on when none of the other
alarms is tripped.
Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC, 30 V DC
Maximum switching power: 750 VA, 90 W (resistive load)
Minimum load: 5 V DC @ 10 mA
Only ‘P’ turns on with no-alarm-output type. ‘LL’ or ‘HH’
does not turn on with dual-alarm-output type.
All setpoints can be independently set either for Hi or Lo
alarm trip.
Mechanical life: ≥ 5 × 10
6
cycles (rate 180 cycles/min.)
Function indicators:
• Photo MOSFET Relay
Zro, Spn, D/P, Tch, Fnc, Min, Max
Rating: 120 V AC/DC @ 80 mA (resistive load)
ON resistance: ≤ 30 Ω
Display mode status and operation status, amber ON or
blink
Permissible: 250 mW
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
INSTALLATION
Power consumption
•AC:
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,
Approx. 9 VA at 100 V
Approx. 12 VA at 200 V
Approx. 13 VA at 264 V
•DC: Approx. 5 W
m
3
/min, m
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 2/7
http://www.m-system.co.jp/
MODEL: 47LLC
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting
Weight: 300 g (0.66 lb)
PERFORMANCE in percentage of max. span
Accuracy
Display: ±0.1 % ±1 digit
Output: ±0.25 % (DC output = display + output)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Input resolution: Max. 20 bits
Output resolution: Max. 16 bits
Response time: ≤ 0.5 sec.
(alarm output: 0 – 100 % at 90 % setpoint)
≤ 0.5 sec. (DC output: 0 – 90 %)
Excitation: Set value ±250 mV
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (strain gauge
input or excitation or contact input or SG to DC output to HH
output or H output to L output or LL output to power to
ground)
EXTERNAL VIEW
(1) Main Display
HH
H
P
(2) Alarm Indicators
L
LL
Zro Spn D/P
Tch Fnc Min Max
(3) Function Indicators
Max/Min
Alarm/
Scale/
Shift
Up
(8) Up Button
(7) Shift Button
(6) Scale/ Button
(4) Max/Min Button
(5) Alarm/ Button
• COMPONENT IDENTIFICATION
No. COMPONENT
(1) Main display
FUNCTION
Indicates present values, setting values and status of the unit.
Indicate alarm status of the input signal.
(2) Alarm indicators
(3) Function indicators
(4) Max/Min button
Indicate the status in each setting mode.
Used to switch the main display to show the present values, maximum values or minimum values etc.
(5)
Used to con!rm alarm setting value and to move on to the alarm and other setting modes; or to shift through
setting items in each setting mode.
Alarm/ button
(6)
Used to move on to the scaling and other setting modes; or to shift through setting items in each setting
mode.
Scale/ button
(7) Shift button
(8) Up button
Used to move on to the setting standby status of each setting mode and shift through display digits in each
setting item.
Used to select setting values in each setting mode.
Note: Refer to the operating manual for details on each function.
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 3/7
http://www.m-system.co.jp/
MODEL: 47LLC
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
■ TOP VIEW
95 (3.74)
■ FRONT VIEW
■ SIDE VIEW
103 (4.06)
96 (3.78)
98.5 (3.88)
86 (3.39)
12.5 (.49)
2 (.08)
■ REAR VIEW
20–M3 SCREW
TERMINAL
6.6 (.26)
4–M3 SCREW
1
2
3
4
5
6
7
8
9
10
20
11
12
13
14
15
16
17
18
19
91.5 (3.60)
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 4/7
http://www.m-system.co.jp/
MODEL: 47LLC
MOUNTING REQUIREMENTS unit: mm
92 +– 00.8
min. 120
Panel thickness: 1.6 to 8.0 mm
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 5/7
http://www.m-system.co.jp/
MODEL: 47LLC
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ No alarm output
Isolation
STRAIN
GAUGE
Output
Driver
+
–
+
+
1
2
7
8
9
Low Drift
Amplifier
DC OUTPUT
POWER
INPUT
EXC.
–
3
U(+)
Low Drift
DC Volt.
Stabilizer
Digital
Computation
–
4
10 V(–)
SG
5
15
16
17
18
19
20
Display /
Setting
6
+
–
11
12
CONTACT
INPUT (Di)
13
14
■ N.O. Contact, 4 points / Photo MOSFET relay, 4 points
Isolation
STRAIN
GAUGE
Output
Driver
+
–
+
+
–
1
2
7
8
Low Drift
Amplifier
DC OUTPUT
INPUT
EXC.
Ry
Ry
3
Low Drift
DC Volt.
Stabilizer
Digital
Computation
15 HHa
16 Ha
–
4
HH OUTPUT
H OUTPUT
SG
5
Display /
Setting
17 Hc, HHc
Ry
Ry
6
18 La
+
–
11
12
13
14
L OUTPUT
CONTACT
INPUT (Di)
19 LLa
LL OUTPUT
20 Lc, LLc
U(+)
10 V(–)
9
POWER
■ SPDT contact, 2 points
Isolation
STRAIN
GAUGE
Output
Driver
+
–
+
+
–
1
2
7
8
Low Drift
Amplifier
DC OUTPUT
INPUT
EXC.
Ry
3
Low Drift
DC Volt.
Stabilizer
Digital
Computation
15 Ha(NO)
16 Hb(NC)
–
4
H OUTPUT
L OUTPUT
SG
5
Display /
Setting
17 Hc(COM
18 La(NO)
19 Lb(NC)
)
Ry
6
+
–
11
12
13
14
CONTACT
INPUT (Di)
20 Lc(COM
U(+)
10 V(–)
)
9
POWER
■ Relay Protection
• AC Powered
Note: The section enclosed by broken line is only with
DC output option.
• DC Powered
Inductive
Load (Coil)
Inductive
Load (Coil)
Diode, Varistor or
CR Circuit
Varistor or
CR Circuit
LOAD
LOAD
U
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 6/7
http://www.m-system.co.jp/
MODEL: 47LLC
Specifications are subject to change without notice.
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 7/7
http://www.m-system.co.jp/
47LLC-S363B-M2 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
47LLC-S363B-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363B-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363B-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363B-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363BG-M2 | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363BG-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363BG-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363BG-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363BG-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LLC-S363BG-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 |
47LLC-S363B-M2 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8