47LPA-1A1BG-M2 概述
Digital Panel Meters 47 Series
47LPA-1A1BG-M2 数据手册
通过下载47LPA-1A1BG-M2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: 47LPA
Digital Panel Meters 47 Series
[2] ALARM OUTPUT
0: None
1: N.O. relay contact, 4 points
2: SPDT relay contact, 2 points
FREQUENCY INPUT DIGITAL PANEL METER
(4½ digit, LED display type)
Functions & Features
• 4 ½ digit digital panel meter
• 1/8 DIN size
[3] DISPLAY COLOR
R: Red
• Accepts a pulse train input to measure rotation count or
period
YR: Orange
G: Green
• Scaled reading representing speed (m/s), rotation (rpm)
and other counts
BG: Bluegreen
B: Blue
• Alarm tone optional
W: White
• Max. and Min. value display
• IP66 front panel
[4] POWER INPUT
AC Power
• Separable terminal block
• Rear terminal cover for safety strapped to the meter
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
DC Power
R: 24 V DC
96 (3.78)
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
H
H
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
H
48
(1.89)
P
L
L
L
Zr
o
Sp
n
D/P
Tc
h
Fnc
Mi
n
Max
Ma
x/M
in
A
la
rm
/
S
ca
le
/
S
hif
t
U
p
98.5 (3.88)
[5] OPTIONS (multiple selections)
Alarm Tone
mm (inch)
blank: Without
/B: With (selectable only with alarm output)
Other Options
MODEL: 47LPA-1[1][2][3]-[4][5]
blank: none
/Q: Option other than the above (specify the specification)
ORDERING INFORMATION
• Code number: 47LPA-1[1][2][3]-[4][5]
Specify a code from below for each of [1] through [5].
(e.g. 47LPA-1A1G-M2/B/Q)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
/C02: Polyurethane coating
/C03: Rubber coating
INPUT
1: Open collector or voltage pulse
TERMINAL SCREW MATERIAL
/S01: Stainless steel
EX-FACTORY SETTING
[1] DC OUTPUT
0: Without
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9515)
Current
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
Voltage
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Degree of protection: IP66; applicable to the front of the
panel meter mounted according to the specified panel
cutout
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
Connection: M3 separable screw terminal (torque 0.6 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 1/8
https://www.m-system.co.jp/
MODEL: 47LPA
Housing material: Flame-resistant resin (gray)
Isolation: Input to DC output to HH output or H output to
L output or LL output to power
Setting: (Front button)
INPUT SPECIFICATIONS
Sensor excitation: 12 V DC ±10 %, 30 mA
Current limit protection at approx. 60 mA
Frequency range: 0 – 0.01 Hz through 100 kHz
A wave that has constant frequency and variable duty ratio
cannot be measured.
• Scaled range
• Input type
• Alarm setpoint
Time period range: 0 – 1 sec. through 100 sec.
Minimum pulse width requirements: 5 μsec. for both ON and
OFF
• Hysteresis (deadband)
• Others
(Refer to the instruction manual for details)
Lockout setting: Prohibiting certain operations; protecting
settings
Default setting: 0 – 100 kHz
■ Open Collector
Detecting voltage/current: Approx. 8 V DC @ 1.6 mA
Detecting levels: ≤ 300 Ω / 0.6 V for ON;
≥ 10 kΩ / 4.5 V for OFF
DISPLAY
■ Voltage Pulse
Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED
Input indication: ‘D/P’ turns on for 1 second after a valid
pulse train has been detected (applied to 1/100 scaled
signal for the input ranges F10K, F0.1M).
‘Tch’ turns on with control input.
Voltage range: 0 – 5 through 26.4 V
±5 – ±26.4 V (equal amplitude at both poles, or ±10 V min.
with frequency ≥ 50 kHz)
Waveform: Square (detecting sinking pulse edges)
Input impedance: ≥ 10 kΩ
Display range: -19999 to 19999
Low level: -26.4 – 0.6 V DC
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none
Zero indication: Higher-digit zeros are suppressed.
Over-range indication: ‘-19999’ or ‘19999’ blinking for
display values out of the scaled range.
‘S.ERR’ and ‘Max’ blinking when the input signal is out of
the usable range.
High level: 4.5 – 26.4 V DC
■ Control Input: Halt measuring
Detecting time: ≥ 200 msec.
Detecting levels: 4.5 – 26.4 V or short circuit across the
terminals 1 and 5 for ON; -26.4 – 0.6 V for OFF
Alarm status indication
LL indicator: Green LED turns on when the LL alarm is
tripped.
OUTPUT SPECIFICATIONS
■ DC Output
L indicator: Green LED turns on when the L alarm is
tripped.
• DC Current
Operational range: -5 – +105 %
• DC Voltage
H indicator: Red LED turns on when the H alarm is tripped.
HH indicator: Red LED turns on when the HH alarm is
tripped.
Operational range: -5 – +105 %
■ Alarm Output: Relay contact
Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC, 30 V DC
Maximum switching power: 750 VA, 90 W (resistive load)
Minimum load: 5 V DC @ 10 mA
P indicator: Amber LED turns on when none of the other
alarms is tripped.
Only ‘P’ turns on with no-alarm-output type. ‘LL’ or ‘HH’
does not turn on with dual-alarm-output type.
All setpoints can be independently set either for Hi or Lo
alarm trip.
Mechanical life: ≥ 5 × 10 cycles (rate 180 cycles/min.)
6
Function indicators:
Zro, Spn, D/P, Tch, Fnc, Min, Max
INSTALLATION
Power consumption
•AC: Approx. 6.5VA
•DC: Approx. 3 W
Display mode status and operation status, amber ON or
blink
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m
3, m3/sec,
Weight: 300 g (0.66 lb)
m3
/min, m
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 2/8
https://www.m-system.co.jp/
MODEL: 47LPA
PERFORMANCE
Accuracy
Display: ±0.1 % or ±1 digit
Output: ±0.1 % (DC output = display + output)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Output resolution: Max. 14 bits
Response time: [One input cycle + 0.5 sec.] or less (alarm
output: 0 – 100 % at 90 % setpoint)
[One input cycle + 0.5 sec.] or less
(DC output: 0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (input to DC
output to HH output or H output to L output or LL output to
power to ground)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Measurement Category II (alarm output)
Installation Category II (power)
Pollution degree 2
Input or DC output to alarm output to power: Reinforced
insulation
(300 V)
Input to DC output: Basic insulation (300 V)
RoHS Directive
Protection against access to the terminal blocks:
Finger protection (VDE 0660-514)
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 3/8
https://www.m-system.co.jp/
MODEL: 47LPA
EXTERNAL VIEW
(1) Main Display
HH
H
P
(2) Alarm Indicators
L
LL
Zro Spn D/P
Tch Fnc Min Max
(3) Function Indicators
Max/Min
Alarm/
Scale/
Shift
Up
(8) Up Button
(7) Shift Button
(6) Scale/ Button
(4) Max/Min Button
(5) Alarm/ Button
• COMPONENT IDENTIFICATION
No. COMPONENT
(1) Main display
FUNCTION
Indicates present values, setting values and status of the unit.
Indicate alarm status of the input signal.
(2) Alarm indicators
(3) Function indicators
(4) Max/Min button
Indicate the status in each setting mode.
Used to switch the main display to show the present values, maximum values or minimum values etc.
(5)
Used to con!rm alarm setting value and to move on to the alarm and other setting modes; or to shift through
setting items in each setting mode.
Alarm/ button
(6)
Used to move on to the scaling and other setting modes; or to shift through setting items in each setting
mode.
Scale/ button
(7) Shift button
(8) Up button
Used to move on to the setting standby status of each setting mode and shift through display digits in each
setting mode.
Used to select setting values in each setting mode.
Note: Refer to the operating manual for details on each function.
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 4/8
https://www.m-system.co.jp/
MODEL: 47LPA
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
■
TOP VIEW
95 (3.74)
■
FRONT VIEW
■ SIDE VIEW
103 (4.06)
96 (3.78)
98.5 (3.88)
86 (3.39)
12.5 (.49)
2 (.08)
■
REAR VIEW
• Alarm Output
• No Alarm Output
10–M3 SCREW
TERMINAL
20–M3 SCREW
TERMINAL
6.6 (.26)
2–M3 SCREW
4–M3 SCREW
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
20
11
12
13
14
15
16
17
18
19
91.5 (3.60)
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 5/8
https://www.m-system.co.jp/
MODEL: 47LPA
MOUNTING REQUIREMENTS unit: mm
92 +– 00.8
min. 120
Panel thickness: 1.6 to 8.0 mm
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 6/8
https://www.m-system.co.jp/
MODEL: 47LPA
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ ALARM OUTPUT CODE 0: No alarm output
Isolation
Sensor
Excitation
Output
Driver
EXC+
OC JP
INP+
1
2
3
4
5
+
–
7
8
9
SHORT- CIRCUIT*1
SENSOR EXCITATION
DC OUTPUT
Input
Circuit
1/100
Scaler
Digital
Computation
INPUT
U(+)
COM
–
POWER
Control
Input
CONTROL INPUT*2
10 V(–)
DI+
Display /
Setting
6
■ ALARM OUTPUT CODE 1: N.O. contact, 4 points
Isolation
Sensor
Excitation
Output
Driver
EXC+
OC JP
INP+
1
2
3
4
5
+
–
7
8
SHORT- CIRCUIT*1
SENSOR EXCITATION
DC OUTPUT
Input
Circuit
1/100
Scaler
INPUT
Ry
Ry
Digital
Computation
COM
*
–
15 HHa
16 Ha
Control
Input
2
CONTROL INPUT
HH OUTPUT
H OUTPUT
DI+
6
17 Hc, HHc
Ry
Ry
11
12
13
14
18 La
L OUTPUT
19 LLa
LL OUTPUT
20 Lc, LLc
U(+)
10 V(–)
9
POWER
■ ALARM OUTPUT CODE 2: SPDT contact, 2 points
Isolation
Sensor
Excitation
Output
Driver
1
2
3
4
5
EXC+
OC JP
INP+
+
–
7
8
SHORT- CIRCUIT*1
SENSOR EXCITATION
DC OUTPUT
Input
Circuit
1/100
Scaler
INPUT
Ry
Digital
Computation
COM
*
–
15 Ha(NO)
16 Hb(NC)
Control
Input
2
CONTROL INPUT
DI+
H OUTPUT
L OUTPUT
6
17 Hc(COM
18 La(NO)
19 Lb(NC)
)
Ry
11
12
13
14
20 Lc(COM
U(+)
10 V(–)
)
9
POWER
*1. Close across the terminals for open collector. Refer to the figure below.
*2. For detailed connection of CONTROL INPUT, refer to the operating manual (EM-9515-B).
■ Input Connection Example
• Open Collector
■ Relay Protection
• AC Powered
• DC Powered
Inductive
Load (Coil)
Inductive
Load (Coil)
1
Short
8V
Varistor or Spark
Quenching Circuit
Diode, Varistor or
CR Circuit
LOAD
LOAD
2
5kΩ
3
U
Note 1: The section enclosed by broken line is only with DC output option.
Note 2: Chattering input signals cannot be measured accurately.
Add a capacitor (10000 pF) or similar devices to the input terminals to eliminate
the input signals’ instability.
4
5
COM
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 7/8
https://www.m-system.co.jp/
MODEL: 47LPA
Specifications are subject to change without notice.
47LPA SPECIFICATIONS
ES-9515 Rev.13 Page 8/8
https://www.m-system.co.jp/
47LPA-1A1BG-M2 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
47LPA-1A1BG-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1BG-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1BG-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1BG-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1BG-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1G-M2 | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1G-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1G-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1G-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPA-1A1G-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 |
47LPA-1A1BG-M2 相关文章
- 2024-11-08
- 22
- 2024-11-08
- 15
- 2024-11-08
- 16
- 2024-11-08
- 14