54UL-2212-AD4/Q [MSYSTEM]
Power Transducer Series;型号: | 54UL-2212-AD4/Q |
厂家: | M-SYSTEM |
描述: | Power Transducer Series |
文件: | 总8页 (文件大小:353K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: 54UL
Power Transducer Series
[2] INPUT
1: 480 V / 1 A AC
2: 480 V / 5 A AC
MULTI POWER MONITOR
(4 digital displays, LonWorks)
Functions & Features
[3] DISCRETE INPUT
• LonWorks communication
0: None (‘External Interface’ code 1 Not selectable.)
1: 24V DC ('External Interface' codes 2 Not selectable.)
2: 110V DC ('External Interface' codes 2 Not selectable.)
• Measures simultaneously several variables of a heavy-
current power system: current, voltage, active, reactive and
apparent power, active and reactive energy, power factor,
frequency, etc.
[4] EXTERNAL INTERFACE
1: LonWorks, Do × 1, Di × 1
2: LonWorks, Do × 2
• All measured values, counter values, display mode,
setting data are stored in the non-volatile memory at the
power off
• Parameters are programmable using the front buttons or
the PC via infrared interface
AUXILIARY POWER SUPPLY
AD4: universal
• Mounted using M5 screws or mounting brackets
• 60-segment bargraph
100 – 240 V AC (Operational range 85 – 264 V, 50 / 60 Hz) /
110 – 240 V DC (Operational range 99 – 264 V,
ripple 10 %p-p max)
• Displayed measurands are freely selectable
• Open collector output for alarm or energy count
• Loop test output
[5] OPTIONS (multiple selections)
Language
Typical Applications
• Multi-functional power monitor incorporated in an electric
device: saves space, wiring works, and cost
blank: Japanese
/E: English
Other Options
110 (4.33)
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
110
(4.33)
125
*
(4.92)
/C02: Polyurethane coating
mm (inch)
/C03: Rubber coating
*140 (5.51) for 54Ux-2
TERMINAL SCREW MATERIAL
/S01: Stainless steel
MODEL: 54UL-[1][2][3][4]-AD4[5]
RELATED PRODUCTS
ORDERING INFORMATION
• Code number: 54UL-[1][2][3][4]-AD4[5]
Specify a code from below for each of [1] through [5].
(e.g. 54UL-1211-AD4/E/Q)
• Infrared Communication Adaptor (model: COP-IRU)
• PC configurator software (model: PMCFG)
• XIF File (Device Interface File)
XIF file is used to define a LonWorks device when
programmed on LonMaker.
• Specify the specification for option code /Q
(e.g. /C01/S01)
The XIF files and Software are downloadable at M-System’s
web site.
[1] CONFIGURATION
1: Single phase / 2-wire and 3-wire, 3-phase / 3-wire
2: Single phase / 2-wire and 3-wire,
3-phase / 3-wire and 4-wire
GENERAL SPECIFICATIONS
Construction: 110-mm square panel flush mounted
Degree of protection
Front panel: IP 50
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 1/8
http://www.m-system.co.jp/
MODEL: 54UL
Terminal block, housing: IP 30
Service lamp: Red LED (used as infrared LED for
Connection
communication with COP-IRU)
Voltage input: M4 screw terminals (torque 1.4 N·m)
Current input: M4 screw terminals (torque 1.4 N·m)
Discrete input, discrete output, LonWorks, auxiliary power
supply: M3 screw terminals (torque 0.6 N·m)
Configuration
• Off: Normal operations
• Blinking in approx. 0.5 Hz: No network information
• On: Internal program error
SERVICE switch: Used to identify the node in LonWorks
network configuration
Code 1: Single phase/2-wire and 3-wire, 3-phase/3- wire
balanced/unbalanced load
RESET switch: Resetting the Neuron Chip
Code 2: Single phase/2-wire and 3-wire, 3-phase/3- wire
balanced/unbalanced load, 3-phase/4- wire
balanced/unbalanced load
INPUT SPECIFICATIONS
Frequency: 50 / 60 Hz (45 – 65 Hz)
• Voltage Input
Screw terminal
Rated voltage
• M3 screw: Nickel-plated steel (standard) or stainless steel
• M4 screw: Nickel-plated brass (standard) or stainless steel
Housing material: Flame-resistant resin (black)
Isolation: Voltage input to current input to discrete input to
LonWorks or FG to discrete output to power
■ Measured variables
Line-to-line (delta voltage): 480 V
Line-neutral (phase voltage): 277 V
Consumption VA: ≤ ULN2 / 300 kΩ / phase
Overload capacity: 200 % of rating for 10 sec., 120 %
continuous
Selectable primary voltage range: 50 – 400 000 V
• Current Input
Voltage: 1 – 2, 2 – 3, 3 – 1, 1 – N, 2 – N, 3 – N
Current: 1, 2, 3, N
Rated current: 1 A or 5 A
Active / reactive / apparent power: 1, 2, 3, Σ
Power factor: 1, 2, 3, Σ
Consumption VA: ≤ I · 0.01 Ω / phase
2
Overload capacity: 4000 % of rating for 1 sec., 2000 % for
4 sec., 120 % continuous
Frequency
Phase angle between voltages: 1 – 2, 2 – 3, 3 – 1
Active energy incoming / outgoing: Σ
Reactive energy inductive / capacitive: Σ
Apparent energy: Σ
Selectable primary current range: 1 – 20 000 A
Operational range
Voltage, current, apparent power: ≤ 120 % of the rating
Active / reactive power: -120 to +120 % of the rating
Frequency: 45 – 65 Hz
Active / reactive / apparent power intervals (demand)
Current intervals (demand): 1, 2, 3, N
Harmonic contents: Σ, 2nd to 31st
Voltage: 1 – 2, 2 – 3, 3 – 1, 1 – N, 2 – N, 3 – N
Current: 1, 2, 3, N
Power factor: -1 to +1
■ Discrete Input: 24 V DC or 110 V DC
(input resistance 6 kΩ)
Detecting voltage: External 24 V DC ±10 % or 110 V DC
±10 %
Max. and min. values: 1 = R, 2 = S, 3 = T
Infrared communication: Transmission distance max. 1
meter (for use with the COP-IRU and PMCFG)
■ DISPLAY: LCD with LED backlight (LED OFF timer
available)
ON current: ≥ 1 mA (≤ 24 kΩ @ 24 V, ≤ 110 kΩ @110 V)
OFF current: ≤ 0.1 mA (≥ 240 kΩ @ 24 V, ≥ 1.1 MΩ @ 110
V)
Detecting time: 10 – 1000 msec.
Usable to reset energy count or to update average
(demand) value.
Signed: 4 digits, 2 lines
Energy: 9 digits, 1 line
Bargraph: 1 point (60 segments)
OUTPUT SPECIFICATIONS
■ Open Collector
LonWorks COMMUNICATION
Neuron chip: FT3150 (NeuronID printed in numeric and
bar code [peel-off code 39 format] under the
specification marking on the product; two
sticker labels attached)
Programmable for either alarm or energy count.
Max. rated load: 130 V DC @50 mA
Continuous rated load: 130 V DC @30 mA
Saturation voltage: 1.5 V DC
Transceiver: FT-X1 (equivalent to FTT-10A)
Transmission speed: 78 kbps Twisted-pair cable
Distance, free topology: 500 meters
Max. 64 nodes/channel
Measurands applicable to alarm: Voltage, current, average
current (demand), neutral current, frequency, power,
average power (demand)
(ON delay, deadband and other parameters are selectable)
LNS: Ver.3.0 Service Pack 8 or higher
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 2/8
http://www.m-system.co.jp/
MODEL: 54UL
Measurands applicable to count: Energy;
Pulse rate selectable within
0.1 – 10 000.0 kWh/p, kvarh/p, kVAh/p
INSTALLATION
Power consumption
•AC: < 8 VA
•DC: < 4 W
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -20 to +80°C (-4 to +176°F)
Operating humidity: 90 % RH max. (non-condensing)
Mounting: Panel flush mounting (M5 screws (torque 2 N·m)
or mounting brackets)
Weight
Configuration Code 1: 500 g (1.1 lb)
Configuration Code 2: 525 g (1.16 lb)
PERFORMANCE
Accuracy
(at 23°C ±10°C or 73.4°F ±18°F, 45 – 65 Hz)
Voltage: ±0.3 %; Rated voltage at ≥ 100 V, 100 V at < 100
V
Current: ±0.3 %; of Span 1 A or 5 A
Power: ±0.5 %; Rated voltage/current at ≥ 100 V
Wattage as listed below at < 100 V:
173.2 W (1 A) or 866 W (5 A) for 3ph/3w
100 W (1 A) or 500 W (5 A) for 1ph/2w
200 W (1 A) or 1000 W (5 A) for 1ph/3w
300 W (1 A) or 1500 W (5 A) for 3ph/4w
PF: ±0.5 %
Frequency: ±0.1 % of Span
Energy: ±1 %
Harmonic: ±1 % of Span
Sampling rate: 64 samples per cycle
Data update period:
Harmonic contents and frequency: ≤ 1.1 sec.
Other: ≤ 600 msec.
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(voltage input to current input to discrete input to LonWorks
or FG to discrete output to power)
2000 V AC @1 minute (circuits to housing)
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 3/8
http://www.m-system.co.jp/
MODEL: 54UL
MOUNTING REQUIREMENTS
■ PANEL CUTOUT unit: mm (inch)
• USING MOUNTING SCREWS
Remove the mounting brackets.
• USING MOUNTING BRACKETS
Remove the mounting screws.
45 (1.77)
45 (1.77)
+
0.8 (3.65)
0 (3.63)
92
2–6 (.24) ꢀia.
Panel thickness : 2 to 10 (.08 to .39)
Panel thickness : 2 to 15 (.08 to .59)
EXTERNAL VIEW
FRONT VIEW
REAR VIEW
• Configuration Code 1
2
Voltage Input
Terminals
Current Input
Terminals
Data Displays
Auxiliary Power
Supply Terminals
Discrete I/O
LONWORKS
Terminals
SERVICE
PQS
Control Buttons
Terminals
IU
PF THD
MAX
E PRG ESC
Service Lamp/
Infrared Interface
Infrared Interface
• Configuration Code 2
Voltage Input
Terminals
2
Current Input
Terminals
Auxiliary Power
LONWORKS
Terminals
Supply Terminals
Discrete I/O
Terminals
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 4/8
http://www.m-system.co.jp/
MODEL: 54UL
TERMINAL CONNECTIONS
■ CONFIGURATION CODE: 1
2
P1
P2
P3
1S
1L
3S
3L
DO/PO
+
U(+)
NC
DI
+
NC
FG NET1 NET1
DO/PO
V(
)
NC
DI
NC
FG NET2 NET2
System /
Application
System /
Application
Terminal
Terminal
P1 P2
1S 1L
P1 P2
1S 1L
P1 P2 P3 1S 1L 3S 3L
P1 P2 P3 1S 1L 3S 3L
k
l
k
l
source
1
load
source
load
source
1
load
source
1
load
Single-phase /
3-wire
1
2
K
L
K
L
k
l
2
N / 2
2 / 3
N / 2
2 / 3
Single-phase /
2-wire
K
L
Three-phase /
3-wire,
P1 P2
1S 1L
P1 P2 P3 1S 1L 3S 3L
unbalanced load
(2CT)
u
v
u
v
v
u
k
l
k
l
source
1
U
V
load
source
1
load
U
V
V
U
K
L
K
L
k
l
2
N / 2
2 / 3
K
L
P1 P2 P3 1S 1L
P1 P2 P3 1S 1L
k
l
source
1
load
source
1
load
K
L
2
3
2
3
Three-phase /
3-wire,
balanced load
P1 P2 P3 1S 1L
u
v
v
u
k
l
source
1
load
U
V
V
U
K
L
2
3
Note: For low voltage circuit, grounding is not required.
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 5/8
http://www.m-system.co.jp/
MODEL: 54UL
■ CONFIGURATION CODE: 2
P1
P2
P3
N
2
NC
1S
1L
2S
2L
3S
3L
DO/PO
U(+) NC
V(
DI+ NC FG NET1 NET1
+
)
NC DO/PO DI
–
NC
FG NET2 NET2
System /
Application
System /
Application
Terminal
Terminal
P1 P2
1S 1L
P1 P2
1S 1L
P1 P2 P3 1S 1L 3S 3L
P1 P2 P3 1S 1L 3S 3L
k
l
k
l
source
1
load
source
load
source
1
load
source
1
load
Single-phase /
3-wire
1
2
K
L
K
L
k
l
2
N / 2
2 / 3
N / 2
2 / 3
Single-phase /
2-wire
K
L
Three-phase /
3-wire,
P1 P2
1S 1L
P1 P2 P3 1S 1L 3S 3L
unbalanced load
(2CT)
u
v
u
v
v
u
k
l
k
l
source
1
U
V
load
source
1
load
U
V
V
U
K
L
K
L
k
l
2
N / 2
2 / 3
K
L
P1 P2 P3 1S 1L
P1 P2 P3 1S 1L
P1
N
1S 1L
P1
N
1S 1L
k
l
k
l
source
1
load
source
1
load
source
1
load
source
1
load
K
L
K
L
2
3
2
3
2
3
2
3
Three-phase /
3-wire,
balanced load
Three-phase /
4-wire,
balanced load
N
N
P1 P2 P3 1S 1L
P1
N
1S 1L
u
v
u
v
v
u
k
l
k
l
source
1
load
source
1
U
V
load
U
V
V
U
K
L
K
L
2
3
2
3
N
P1 P2 P3
P1 P2 P3
P1 P2 P3
1S 1L 2S 2L 3S 3L
P1 P2 P3
P1 P2 P3
P1 P2 P3
N 1S 1L 2S 2L 3S 3L
source
1
load
load
load
source
1
load
2
3
2
3
N
1S 1L 2S 2L 3S 3L
N 1S 1L 2S 2L 3S 3L
Three-phase /
3-wire,
Three-phase /
4-wire,
k
l
k
l
source
1
source
1
load
k
l
k
l
unbalanced load
(3CT)
unbalanced load
K
L
k
l
K
L
k
l
2
3
2
3
K
L
K
L
K
L
K
L
N
1S 1L 2S 2L 3S 3L
N
1S 1L 2S 2L 3S 3L
u
v
u
v
u
v
u
v
v
u
k
l
k
l
source
1
source
1
load
U
V
V
U
U
V
U
V
U
V
k
l
k
l
K
L
k
l
K
L
k
l
2
3
2
3
K
L
K
L
K
L
K
L
N
Note: For low voltage circuit, grounding is not required.
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 6/8
http://www.m-system.co.jp/
MODEL: 54UL
■ EXTERNAL INTERFACE CODE: 1
■ EXTERNAL INTERFACE CODE: 2
DI+
DO/PO1+
DISCRETE
OUTPUT 1
DISCRETE
INPUT
DI–
DO/PO1–
DO/PO2+
DO/PO+
DISCRETE
OUTPUT
DISCRETE
OUTPUT 2
DO/PO–
DO/PO2–
NET1
NET1
LONWORKS
NET1
LONWORKS
LONWORKS
NET1
NET2
NET2
FG
NET2
LONWORKS
NET2
FG
FG
FG
U(+)
V(–)
U(+)
AUXILIARY POWER
AUXILIARY POWER
–
V( )
• Discrete Input Connection E.g.
• Discrete Output Connection E.g.
DI+
DI–
+
DO/PO+
DO/PO–
+
-
-
COMMUNICATION CABLE CONNECTIONS
HOST PC
54UL
54UL
LONWORKS
LONWORKS
LONWORKS
Terminator
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 7/8
http://www.m-system.co.jp/
MODEL: 54UL
EXTERNAL DIMENSIONS unit: mm (inch)
■ CONFIGURATION CODE: 1
110 (4.33)
25 (.98)
100 (3.94)
91.5 (3.60)
2
2-M5 SCREW
91.5 (3.60)
MOUNTING BRACKET
■ CONFIGURATION CODE: 2
110 (4.33)
25 (.98)
115 (4.53)
2
2-M5 SCREW
MOUNTING BRACKET
Specifications are subject to change without notice.
54UL SPECIFICATIONS
ES-6488 Rev.5 Page 8/8
http://www.m-system.co.jp/
相关型号:
54VCXH162244
LOW VOLTAGE CMOS 16-BIT BUS BUFFER (3-STATE INV) WITH 3.6V TOLERANT INPUTS AND OUTPUTS
STMICROELECTR
54VCXH162244_07
Low voltage CMOS 16-bit bus buffer (3-state inverter) with 3.6V tolerant inputs and outputs
STMICROELECTR
54VCXH162244_11
Low voltage CMOS 16-bit bus buffer (3-state non inverter) with 3.6 V tolerant inputs and outputs
STMICROELECTR
54VCXH162245
Rad hard low voltage CMOS 16-bit bus buffer transceiver (3-state) with 3.6V tolerant inputs and outputs
STMICROELECTR
54VCXH162245_11
Rad hard low voltage CMOS 16-bit bus buffer transceiver (3-state) with 3.6 V tolerant inputs and outputs
STMICROELECTR
54VCXH162373
Rad hard low voltage CMOS 16-bit D-type latch (3-state) with 3.6V tolerant inputs and outputs
STMICROELECTR
©2020 ICPDF网 联系我们和版权申明