61M-162-R [MSYSTEM]
Field Network Modules 61-UNIT Series;型号: | 61M-162-R |
厂家: | M-SYSTEM |
描述: | Field Network Modules 61-UNIT Series |
文件: | 总5页 (文件大小:152K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: 61M
Field Network Modules 61-UNIT Series
[3] OPTIONS
blank: none
/Q: With options (specify the specification)
ANALOG I/O MODULE
(Modbus; RS-485)
Functions & Features
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
• Interfacing analog I/O signals from/to Mini-M, Pico-M and
other signal conditioner modules with Modbus
• Saving power and I/O wiring inside an instrumentation
panel
/C02: Polyurethane coating
/C03: Rubber coating
RELATED PRODUCTS
• Installation Base (model: M2BS2)
• Installation Base (model: M8BS2)
50
(1.97)
100
(3.94)
PACKAGE INCLUDES...
12
4
5
0
7 6
9
12
4
5
0
• Terminating resistor (110 Ω, 0.25 W)
7 6
9
115
(4.53)
GENERAL SPECIFICATIONS
Construction: Plug-in
mm (inch)
Connection
Modbus: Euro type connector terminal (applicable wire
size: 0.2 to 2.5 mm , stripped length 7 mm)
2
MODEL: 61M–16[1]–[2][3]
I/O: Via Installation Base (model: MxBS2)
Power input: Via Installation Base (model: MxBS2)
Housing material: Flame-resistant resin (black)
Isolation: I/O to Modbus to power
ORDERING INFORMATION
• Code number: 61M-16[1]-[2][3]
Specify a code from below for each [1] through [3].
(e.g. 61M-161-K/Q)
Power indicator: Green LED turns on with power supplied.
• Specify the specification for option code /Q
(e.g. /C01)
MODBUS COMMUNICATION
Communication: Conforms to TIA/EIA-485-A
Transmission setting: DIP switch
NO. OF CHANNELS
Data: RTU (Binary) or ASCII
16: 16 points
Parity: none, even or odd
Baud rate: 4800, 9600, 19.2 k, 38.4 k (bps)
Node address setting: Rotary switch; 01 – F7
(factory setting: 00)
[1] I/O TYPE
1: Input
L RUN indicator: Red LED turns on for 10 sec. when the
module receives data.
2: Output
L ERR. indicator: Red LED turns on at errors in parity,
framing, overrun, CRC or LRC.
[2] POWER INPUT
AC Power
SD indicator: Red LED turns on when transmitting.
RD indicator: Red LED turns on when receiving.
Analog input: Programming Unit (model: PU-2x) or via
Modbus
K: 85 – 132 V AC
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
DC Power
R: 24 V DC
Moving averaging: None, every 2 or 4 samples
Sampling rate: 400, 240, or 160 (msec.)
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
(Specify power suffix code R (24 V DC) when the UNIT is to be
combined with the M8BS2.)
61M SPECIFICATIONS
ES-6631 Rev.9 Page 1/5
http://www.m-system.co.jp/
MODEL: 61M
Insulation resistance: ≥ 100 MΩ with 500 V DC
INPUT SPECIFICATIONS
■ Analog Input
Dielectric strength: 1500 V AC @ 1 minute (I/O to Modbus to
power)
Input range: 1 – 5 V DC
Input resistance: ≥ 1 MΩ
(Each input must be isolated by signal conditioners. Non-
isolated modules such as M2BW and M8BW are not usable.)
■ A/D conversion output
•Signed binary (2-byte data)
Signal range 0 – 100 % is proportional to hexadecimal 0000
– 2710 (0 – 10000). -15 to 0 % is a negative range
represented by 2's complements.
Overall range is represented by hexadecimal FA24 – 2CEC (-
1500 – +11500), for -15 – +115 %.
•Floating data (4-byte data)
Initial signal range 0 – 100 % is proportional to 0 – 10000,
that is possible to be scaled into a specific range.
OUTPUT SPECIFICATIONS
■ Analog Output
Output range: 1 – 5 V DC
Load resistance: 20 kΩ minimum
(Output must be isolated with signal conditioners.
When the transmission line is open, the last value sampled
before failure is held. Non-isolated modules such as M2BW
and M8BW are not usable. )
■ D/A Conversion Input
•Signed binary (2-byte data)
Signal range 0 – 100 % is proportional to hexadecimal 0000
– 2710 (0 – 10000). -15 to 0 % is a negative range
represented by 2's complements.
Overall range is represented by hexadecimal FA24 – 2CEC (-
1500 – +11500), for -15 – +115 %.
•Floating data (4-byte data)
Initial signal range 0 – 100 % is proportional to 0 – 10000,
that is possible to be scaled into a specific range.
INSTALLATION
Power consumption
•AC: Approx. 4 VA
•DC: Approx. 4 W (160 mA)
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: MxBS2)
Weight: 250 g (0.55 lb)
PERFORMANCE in percentage of span
A/D conversion: ±0.1 %
D/A conversion: ±0.1 %
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Permissible power failure duration: ≤ 10 msec.
61M SPECIFICATIONS
ES-6631 Rev.9 Page 2/5
http://www.m-system.co.jp/
MODEL: 61M
EXTERNAL VIEW
Modular Jack
for Factory Calibration
Power Indicator LED
L RUN
L ERR.
SD
Status Indicator LED
PWR
RD
Node Address No. Setting
Transmission Setting
Euro Type Connector Terminal
for Modbus
1
2
3
4
5
6
MODBUS FUNCTION CODES & SUPPORTED CODES
■ Data and Control Functions
CODE
01
NAME
Read Coil Status
X
X
X
X
X
X
Digital output from the slave
02
Read Input Status
Read Holding Registers
Read Input Registers
Force Single Coil
Status of digital inputs to the slave
General purpose register within the slave
Collected data from the eld by the slave
Digital output from the slave
03
04
05
06
Preset Single Registers
Read Exception Status
Diagnostics
General purpose register within the slave
07
08
X
09
Program 484
10
Poll 484
11
Fetch Comm. Event Counter
Fetch Comm. Event Log
Fetch a status word and an event counter
12
A status word, an event counter, a message count and
a eld of event bytes
13
14
15
16
17
18
19
20
21
22
23
24
Program Controller
Poll Controller
Force Multiple Coils
Preset Multiple Registers
Report Slave ID
X
X
Digital output from the slave
General purpose register within the slave
Slave type / ‘RUN’ status
Program 884 / M84
Reset Comm. Link
Read General Reference
Write General Reference
Mask Write 4X Register
Read/Write 4X Registers
Read FIFO Queue
■ Exception Codes
CODE NAME
01
02
03
04
05
06
07
08
Illegal Function
X
X
X
Function code is not allowable for the slave
Address is not available within the slave
Data is not valid for the function
Illegal Data Address
Illegal Data Value
Slave Device Failure
Acknowledge
Slave Device Busy
Negative Acknowledge
Memory Parity Error
61M SPECIFICATIONS
ES-6631 Rev.9 Page 3/5
http://www.m-system.co.jp/
MODEL: 61M
■ Diagnostic Subfunctions
CODE NAME
00
01
02
03
04
Return Query Data
X
X
X
X
X
Loop back test
Restart Comm. Option
Return Diagnostic Register
Change ASCII Input Delimiter
Force Listen Only Mode
Reset the slave and clear all counters
Contents of the diagnostic data (2 bytes)
Delimiter character of ASCII message
Force the slave into Listen Only Mode
MODBUS I/O ASSIGNMENT
TYPE
ADDRESS
DATA TYPE
2
DATA
1
X
X
X
X
X
X
Coil (0X)
1 – 16
17 – 32
1 – 16
Averaging SW *
Sampling rate SW **
Inputs (1X)
X
X
Analog channel status (active channel)
Analog status (out of range)
Analog input
17 – 32
1 – 16
Input Registers (3X)
Holding Registers (4X)
I
17 – 48
1 – 16
F
I
Analog input
X
X
X
X
Analog output
17 – 48
49 – 80
81 – 112
F
F
F
Analog output
X
X
Full scale
Zero scale
■ Type
1
2
: Analog input
: Analog output
■ Data Type
F
I
: Floating
: Int 0 – 10000 (0 – 100%)
*Averaging SW
1
2
3
: 4 samples
: 2 samples
: None
**Sampling rate SW
17 : 400 millisec.
18 : 240 millisec.
19 : 160 millisec.
EXTERNAL DIMENSIONS unit: mm (inch)
2–M3 SCREWS
12
(.47)
50 (1.97)
38 min.
(1.50)
103 (4.06)
61M SPECIFICATIONS
ES-6631 Rev.9 Page 4/5
http://www.m-system.co.jp/
MODEL: 61M
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
INDICATOR ROTARY
Terminator
DA
LED
SW
*
DB
To Other
Modbus
Devices
RS-485
INTERFACE
DG
SLD
FG
A / D
or
D / A
Conv.
To
Installation
Base
TRANSMISSION
SETTING
I / O
CPU
Modular Jack
for Factory
Calibration
MODULAR JACK
SERIAL
TRANSMISSION
LINE
*Attach the terminating resistor when the module is
at the termination of a transmission line.
■ COMMUNICATION CABLE CONNECTIONS
HOST PC
TERMINATOR
Tx+ / Rx+
ANALOG I/O MODULE
ANALOG I/O MODULE
DA
DB
DA
DB
Tx– / Rx–
SG
DG
SLD
FG
DG
SLD
FG
Rx+
Rx–
FG
FG
Specifications are subject to change without notice.
61M SPECIFICATIONS
ES-6631 Rev.9 Page 5/5