61S-162-R 概述
Field Network Modules 61-UNIT Series
61S-162-R 数据手册
通过下载61S-162-R数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: 61S
Field Network Modules 61-UNIT Series
[3] OPTIONS
blank: none
/Q: With options (specify the specification)
ANALOG I/O MODULE
(Multiplex Transmission System)
Functions & Features
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
• Interfacing analog I/O signals from/to Mini-M or Pico-M
modules with Multiplex Transmission System
• Saving power and I/O wiring inside an instrumentation
panel
/C02: Polyurethane coating
/C03: Rubber coating
50
(1.97)
RELATED PRODUCTS
• Installation Base (model: M2BS2)
• Installation Base (model: M8BS2)
100 (3.94)
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection
115 (4.53)
SIN-NET, RUN contact output: Euro type connector
mm (inch)
terminal (applicable wire size: 0.2 to 2.5 mm
2,
stripped length 7 mm)
I/O: Via Installation Base (model: MxBS2)
MODEL: 61S–16[1]–[2][3]
Power input: Via Installation Base (model: MxBS2)
Housing material: Flame-resistant resin (black)
Isolation: I/O to SIN-NET to RUN contact output to power
Power indicator: Red LED turns ON in normal conditions;
OFF when the voltage level becomes low.
RUN indicator: Red LED turns ON when the selfdiagnosis
proves normal, OFF in an abnormality.
ORDERING INFORMATION
• Code number: 61S-16[1]-[2][3]
Specify a code from below for each [1] through [3].
(e.g. 61S-161-K/Q)
• Specify the specification for option code /Q
(e.g. /C01)
■ RUN Contact Output: Contact opens at error
Rated load: 30 V DC @ 0.4 A (resistive load)
Maximum switching voltage: 125 V DC
NO. OF CHANNELS
Maximum switching power: 60 W
16: 16 points
Minimum load: 10 mV DC @ 1 mA
Mechanical life: 5 x 10
7
cycles
Self-diagnosis
[1] I/O TYPE
1: Input
Communication: The receiver modules detect loss of
communication and wire break.
CPU: Watch-dog timer
2: Output
Memory: Sum check
[2] POWER INPUT
AC Power
Power voltage: Detects when the voltage supply to the
CPU drops.
K: 85 – 132 V AC
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
(Specify power suffix code R (24 V DC) when the UNIT is to be
combined with the M8BS2.)
61S SPECIFICATIONS
ES-6637 Rev.2 Page 1/5
http://www.m-system.co.jp/
MODEL: 61S
Dielectric strength: 1500 V AC @ 1 minute (I/O to SIN-NET to
RUN contact output to power)
COMMUNICATION
Configuration: Multi-drop
Standard: Conforms to EIA RS-422
Communication: 2-wire, half-duplex
Transmission speed: 125 kbps
Control procedure: SDLC
Data encoding: NRZ
Protocol: SIN-NET (M-System's)
Error check: CRC
Transmission distance: 500 m
Transmission media: Twisted-pair cable CPEV-0.9 dia.
Station No.: Rotary switch
Terminator: Incorporated (remove jumper pin with those
modules not located at the end of transmission line)
INPUT SPECIFICATIONS
■ Analog Input
Input range: 1 – 5 V DC
Input resistance: ≥ 1 MΩ
(Each input must be isolated by signal conditioners. Non-
isolated modules such as M2BW and M8BW are not usable.)
A / D conversion
Moving averaging: 4 samples
Sampling rate: 160 ms
OUTPUT SPECIFICATIONS
■ Analog Output
Output range: 1 – 5 V DC
Load resistance: 20 kΩ minimum
(Output must be isolated with signal conditioners.
When the transmission line is open, the last value sampled
before failure is held. Non-isolated modules such as M2BW
and M8BW are not usable. )
INSTALLATION
Power consumption
•AC: Approx. 4 VA
•DC: Approx. 4 W (160 mA)
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: MxBS2)
Weight: 250 g (0.55 lb)
PERFORMANCE in percentage of span
A/D conversion: ±0.1 %
D/A conversion: ±0.1 %
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Permissible power failure duration: ≤ 10 msec.
Insulation resistance: ≥ 100 MΩ with 500 V DC
61S SPECIFICATIONS
ES-6637 Rev.2 Page 2/5
http://www.m-system.co.jp/
MODEL: 61S
DESCRIPTIONS
■ RUN Contact Output (LED) Behaviors
• Input module
The LED for the Input Modules turns ON when the network is on-line.
When there is an abnormality in the network, the LED turns OFF.
The network is reconfigured after an abnormality.
• Output module
The LED for the Output Modules turns ON when the network is on-line and the module receives data from the corresponding
Input Module.
When there is an abnormality in the network or there is no data receiving, the LED turns OFF.
■ Station Number (Address)
A) 1 input module and X output modules:
Match the address for input and output modules.
B) Computer interface:
Set address numbers to correspond with the computer as output module.
■ Transmission Time
Integrate all the transmission time for each process input module in the system.
• Analog input 16 points: 24 msec.
An analog module does not transmit all its signals in serial but does 1 point per each cycle. For example, when 1 contact input
module (DLA1, 32 points) and 1 analog input module (16 points) are connected, 32-point contact signal and 1 point analog
signal are transmitted in turn.
One cycle time is therefore calculated as:
32 points x 1.5 msec. + 24 msec. = 72 msec.
This method is beneficial for giving a priority to contact signals which vary rapidly.
■ Applicable models for use with 61S Input Module
• 61S-162 (Ao 16 points)
• DLA1-xM1 (Ao 32 points; only the top 16 out of 32 are used)
61S SPECIFICATIONS
ES-6637 Rev.2 Page 3/5
http://www.m-system.co.jp/
MODEL: 61S
¢
TRANSMISSION LINE CONFIGURATION
The multi-drop transmission line containing 22LA1, DLA1 and
61S modules should meet the following conditions.
Contact M-System's sales office or representatives when
designing.
A) 10 kilometers at maximum in total system.
B) 61S modules plus DLA1 units: One multitransmission
line containing a 60S module can consist of a maximum of
16 units within the total distance of 500 m.
DLA1
61S
DLA1
C) 61S modules plus DLA1 units plus Repeaters (model:
DAL4): DAL4 units can expand the total distance.
(6 DAL4 units max.)
DAL4
DAL4
7
7
61S
DLA1
DLA1
61S
D) 61S modules plus 22LA1 modules plus DLA1 units:
The total distance of a section consists of 61S and 22LA1
modules is less than 500 meters.
They can be connected to DLA1 units via a DLA1-7 unit.
(Eight DLA1-7 units max.)
7
22LA1
61S
DLA1
DLA1
EXTERNAL VIEW
Modular Jack
for Factory Calibration
Power Indicator LED
RUN Indicator LED
PU-2x
PWR
RUN
SIN-NET Terminals
4
4
SA1
Station No. Setting
Rotary Switches
C
C
Terminals for Terminating Resistor
RUN Contact Output
SA2
61S SPECIFICATIONS
ES-6637 Rev.2 Page 4/5
http://www.m-system.co.jp/
MODEL: 61S
EXTERNAL DIMENSIONS unit: mm (inch)
2-M3 SCREW
12
(.47)
38 min
(1.50)
50 (1.97)
103 (4.06)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Station No.
Indicator Setting Rotary
LED Switches
TWISTED-PAIR
Isolation
A
B
C
D
E
F
+
TO OTHER
SIN-NET DEVICES
Control
Circuit
A/D or D/A
Converter
Transceiver
−
TERMINATING RESISTOR
JUMPER PIN*
Ry
To Installation Base
RUN CONTACT
OUTPUT
Modular Jack
for Factory
Calibration
MODULAR
JACK
SERIAL TRANSMISSION LINE
* When the unit is located at the end of transmission line via twisted-pair cable (= no cross-wiring),
short across terminals C - D with the jumper pin (or wire) provided with the unit.
Remove the jumper pin for the one not located at the end.
Specifications are subject to change without notice.
61S SPECIFICATIONS
ES-6637 Rev.2 Page 5/5
http://www.m-system.co.jp/
61S-162-R 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
61S-162-R/Q | MSYSTEM | Field Network Modules 61-UNIT Series | 获取价格 | |
61S100-1-020 | GRAYHILL | Rotary Position Encoder, Single, 2 Channels, | 获取价格 | |
61S100-1-020T | GRAYHILL | SINGLE, 2 CHANNELS, ROTARY OPTICAL POSITION ENCODER | 获取价格 | |
61S100-1-025 | GRAYHILL | Rotary Position Encoder, Single, 2 Channels, | 获取价格 | |
61S100-1-030T | GRAYHILL | SINGLE, 2 CHANNELS, ROTARY OPTICAL POSITION ENCODER | 获取价格 | |
61S100-1-040 | GRAYHILL | Rotary Position Encoder, Single, 2 Channels, | 获取价格 | |
61S100-1-045 | GRAYHILL | Rotary Position Encoder, Single, 2 Channels, | 获取价格 | |
61S100-1-045T | GRAYHILL | SINGLE, 2 CHANNELS, ROTARY OPTICAL POSITION ENCODER | 获取价格 | |
61S100-1-050 | GRAYHILL | Rotary Position Encoder, Single, 2 Channels, | 获取价格 | |
61S100-1-055T | GRAYHILL | SINGLE, 2 CHANNELS, ROTARY OPTICAL POSITION ENCODER | 获取价格 |
61S-162-R 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6