MODEL: 73VR1100  
Paperless Recording System  
[3] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
PAPERLESS RECORDER  
(remote I/O modules)  
Functions & Features  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
• 100 msec. storing rate for the max. of 64 points (1  
station) with the R3-NE1 module  
• Graphic image view helps to recognize measuring points  
and signal status at a glance  
/C02: Polyurethane coating  
/C03: Rubber coating  
• Data stored in CF Cards and SD Cards  
• Memory card slot accessible at the front  
• Real time monitoring at the host PC via Ethernet  
• Dedicated application software to view and analyze the  
data  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
INSTALLATION  
/HA: Desktop type (with handle and feet)  
(Desktop type cannot be mounted on a panel surface.  
The handle and rubber feet cannot be detached.)  
• Touch panel operation  
• IP 65 front panel  
RELATED PRODUCTS  
144 (5.67)  
Please refer to data sheets for the respective models.  
• PC recorder R1M, R2M, R1MS, RZMS series  
• Remote I/O R3 series  
Ethernet (Modbus/TCP) interface module (model: R3-NE1)  
Modbus interface module (model: R3-NM1)  
• Remote I/O R5 series  
144  
(5.67)  
133  
(5.24)  
Ethernet (Modbus/TCP) interface module (model: R5-NE1)  
Modbus interface module (model: R5-NM1)  
• Modbus I/O module (model: R7M)  
mm (inch)  
• Ethernet I/O module, Modbus/TCP (model: R7E)  
R7 configurator software (model: R7CON) To connect with  
R7M series, change Modbus Communication Parameters of  
the R7M by using R7CON and the special cable.  
• Multi power monitor (model: 53U)  
MODEL: 73VR1100-[1]-[2][3]  
ORDERING INFORMATION  
• Code number: 73VR1100-[1]-[2][3]  
Specify a code from below for each of [1] through [3].  
(e.g. 73VR1100-E-M2/Q)  
· Ethernet tower light (Model: IT60RE, IT40SRE, IT50SRE,  
IT60SRE)  
Lamps and buzzer are turned on/off in combination with  
alarm output of 73VR1100.  
• Specify the specification for option code /Q  
(e.g. /C01/S01/HA)  
• Ethernet communication adaptor (model: 72EM2-M4)  
■ Memory card  
A memory card is required to store data in the 73VR1100.  
Available for purchase from M-System. Consult M-System  
(except SD/CF conversion adapter).  
[1] LANGUAGE  
N: Japanese  
E: English  
M-System will not guarantee the product’s described  
performance if a memory card other than purchased from M  
-System, or specified below, is used.  
[2] POWER INPUT  
AC Power  
• CF Card  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
1. Manufacturer: Hagiwara Solutions  
47 – 66 Hz)  
Model No.: MCF10P-xxxxS  
(CE not available for desktop type)  
Capacity: 128 MB through 1 GB  
DC Power  
(CFI-xxxxDG ... discontinued)  
R: 24 V DC  
2. Manufacturer: Apacer Technology  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Model name: CFC III  
Model No.: AP-CFxxxxE3NR-ETNDNRQ  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 1/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
Capacity: 256 MB through 1 GB  
RUN output indicator LED: Green light turns on in normal  
conditions; off in an abnormality.  
Part No.: 81.27L20.TB47C (256 MB)  
81.29910.TB37C (512 MB)  
Power indicator LED: Green light turns on when the power is  
supplied.  
81.29920.TB37C (1 GB)  
(AP-CFxxxxE3ER-ETNDNR, AP-CFxxxxE3ER-ETNDNRK ...  
discontinued)  
INTERFACE  
Ethernet: 10BASE-T / 100BASE-TX automatically switched;  
Conforms to IEEE 802 (10BASE-T) or IEEE 802.3 (100BASE-  
TX)  
• SD Card (Compatible with 73VR1100 Ver.5.03.xx or later)  
Manufacturer: Hagiwara Solutions  
Model No.: NSD6-004GH (B21SEI  
IP address: 192.168.0.1 (factory default setting)  
Subnet mask: 255.255.255.0 (factory default setting)  
Default gateway: None (factory default setting)  
CF Card slot: Type I; for use with the cards’ operating  
voltage 3.3 V  
(NSDA-004GT, NSDA-004GL ... discontinued)  
SD/CF Conversion Adapter is required to use SD card. There  
are some restrictions on using SD card. For details, refer to  
the instruction manual.  
• SD/CF Conversion Adapter (operation confirmed):  
DeLOCK adaptor CF II to SDHC,SDXC  
USB: Conforms to Version 1.1  
DISPLAY  
Model: 61796 (operation has been confirmed with the  
adapter purchased in the year of 2016.)  
62637 (operation has been confirmed with the  
adapter purchased in the year of 2018.)  
Note: Refer to the data sheets of the respective models.  
Display device: 5.5-inch TFT LCD  
Display colors: 256  
Resolution: 320 × 240 pixels  
Pixel pitch: 0.12 × 0.35 mm  
Note: The backlight can be replaced in M-System factory.  
The LCD must be replaced at the same time.  
ALARM / RUN OUTPUT  
PACKAGE INCLUDES...  
• 73VR Application Software CD (model: 73VRPAC2)  
Rated load: 250 V AC @ 0.5 A (cos ø = 1)  
(For desktop type EU conformity: < 50 V AC)  
30 V DC @ 0.5 A (resistive load)  
• Mounting brackets (two)  
(/HA: Not included for desktop type)  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 250 VA or 150 W  
Minimum load: 1 V DC @ 1 mA  
GENERAL SPECIFICATIONS  
Construction: Panel mount type or desktop type  
Degree of protection: IP65; applicable to the front panel of  
the recorder with single mounting according to the specified  
panel cutout (/HA: Desktop type cannot be mounted on a  
panel surface)  
Mechanical life: 2 × 10 cycles (rate 300/min.)  
7
External protection is recommended when driving an  
inductive load.  
RUN output contact: ON in normal conditions; OFF in errors  
(CPU error, application errors)  
CONNECTION  
Alarm output contact: Specified in the application software  
Power input, alarm output, RUN contact output: M3  
separable screw terminal (torque 0.5 N·m)  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
EXTERNAL INTERFACE  
Modbus RTU  
Configuration: Half-duplex, asynchronous, no procedure  
Standard: Conforms to TIA/EIA RS-485-A  
Max. transmission distance: 500 meters  
Transfer rate: 38400 bps  
Ethernet: RJ-45 Modular Jack  
RS-485: Euro type connector terminal  
Transmission media: Shielded twisted-pair cable (CPEV-S  
0.9 dia.)  
Data bit: 8  
Applicable wire size: 0.2 to 2.5 mm or AWG 24 to AWG 12  
2
Parity bit: Odd  
for both stranded and single core wires. stripped length 7  
mm. Use pin terminals with stranded wires.  
■ MATERIALS  
Stop bit: 1  
Max. node number: 15 (except the master)  
Transmission media:  
Enclosure: Steel  
Shielded twisted-pair cable (CPEV-S φ0.9)  
Terminating resistor: incorporated  
Bezel: Flame-resistant resin (black)  
Front filter: Transparent resin  
Isolation: Alarm output to RUN output to power to Ethernet  
to FG or RS-485  
INDICATORS  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 2/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
INSTALLATION  
Power input  
AC:  
Approx. 15 VA at 100 V  
Approx. 20 VA at 240 V  
DC: 8 W or 340 mA  
Operating temperature: 0 to 50°C (32 to 122°F)  
Display quality (e.g. decreased contrast) may deteriorate  
when the recorder is used for a long time in an environment  
exceeding 50°C. However, it is only a temporary  
phenomenon. When the recorder is back in normal  
temperature, full legibility is recovered. No damage in  
performance.  
Operating humidity: 30 to 85 %RH (non-condensing)  
Allowable dust particles: 0.1 mg/m  
2
(no conductive particles)  
Corrosive gas: Not allowed  
Mounting: Panel flush mounting (except desktop type)  
Panel cutout dimensions: 137 × 137 mm (5.39”× 5.39”)  
Weight: 1.7 kg (3.7 lb)  
Caution: Use of UPS (switching time: without delay, output:  
sine waveforms) is recommended to prevent data loss or CF  
card damage by a loss of power during recording.  
PERFORMANCE  
Calendar clock accuracy: Monthly deviation 3 minutes at  
25°C  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 500 V AC @ 1 minute  
(alarm output to RUN output to power or FG or RS-485)  
AC powered:  
2000 V AC @ 1 minute (power to FG or Ethernet or RS-485)  
500 V AC @ 1 minute (FG or RS-485 to Ethernet)  
DC powered:  
1250 V AC @ 1 minute (power to FG or Ethernet or RS-485)  
500 V AC @ 1 minute (FG or RS-485 to Ethernet)  
STANDARDS & APPROVALS  
EU conformity:  
(M2 AC power of desktop type does not conform to EU  
directive)  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
Installation Category II  
Pollution Degree 2  
Alarm output to RUN output to power to FG or Ethernet or  
RS-485: Reinforced insulation (300 V)  
RoHS Directive  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 3/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
APPLICATION SOFTWARE CD  
73VRPAC2 (included in the product package)  
• 73VR1100 Builder Software: Model 73VR11BLD  
Used to configure parameters on the PC.  
- Parameter configurations can be downloaded to the recorder via Ethernet.  
- Present setting on the 73VR1100 can be uploaded and displayed on the PC.  
- Configuration files can be converted into CSV.  
• 73VR Data Viewer: Model 73VRWV  
Used to show and analyze recorded data on the PC.  
- Data stored in the CF Card can be called up on the PC screen via the CF Card Reader.  
- Data stored in the CF Card can be sent by FTP and called up on the PC screen.  
- Various analyzing functions  
- Data, alarm history and comment files can be converted into CSV.  
• PC Recorder Software: Model MSR128-V6  
The 73VR1100 data can be sampled and stored in real time via Ethernet by the MSR128-V6.  
• Instruction Manuals  
- 73VR1100 users manual  
- 73VR11BLD users manual  
- 73VRWV users manual  
- MSR128-V6 users manual  
PC REQUIREMENTS (provided by the user)  
73VR1100 Builder Software: Model 73VR11BLD  
Operating system  
Windows 7 Professional (32-bit) or Windows 10 (32-bit, 64-bit)  
Note: Proper software functions may not be ensured under certain conditions.  
1024 by 768 pixels or better resolution  
Screen area  
CD drive  
Windows supported CD drive is used to install the software program.  
Used to read/write the CF Card  
Card reader  
Mouse  
Windows supported  
LAN card  
LAN card required to connect to Ethernet; 10BASE-T or 100BASE-T cable  
73VR Data Viewer: Model 73VRWV  
Operating system  
Windows 7 Professional (32-bit) or Windows 10 (32-bit, 64-bit)  
Note: Proper software functions may not be ensured under certain conditions.  
1024 by 768 pixels or higher  
Screen area  
Display color  
65000 colors (16-bit)  
Main memory (RAM) 2 GB recommended  
CD drive  
Card reader  
Mouse  
Windows supported CD drive is used to install the software program.  
Used to read/write the CF Card  
Windows supported (Certain functions of the 73VR may be compromised if the mouse’s software driver is  
not Windows standard.)  
LAN card  
LAN card required to connect to Ethernet; 10BASE-T or 100BASE-T cable  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 4/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
PC Recorder Software: Model MSR128-V6  
NORMAL MODE (storing rates ≥ 500 ms)  
IBM PC/AT or compatible  
HIGH SPEED MODE (storing rates 100 / 200 ms)*1  
PC  
Operating system  
Windows XP SP1, SP2, SP3, Windows Vista Business (32-bit), Windows 7 Professional (32-bit) or  
Windows 10 (32-bit, 64-bit)  
Note: Proper software functions may not be ensured under certain conditions.  
CPU  
Pentium III 800 MHz or higher  
1 GHz higher for Windows Vista, Windows 7,  
Windows 10  
Pentium IV 2.0 GHz or higher  
Screen area  
Display color  
Video memory  
Main memory  
1024 by 768 pixels or better resolution  
65000 colors (16-bit)  
2 MB minimum; 4 MB recommended  
4 MB minimum  
256 MB recommended for Windows XP  
512 MB recommended for Windows XP  
1 GB recommended for Windows Vista, Windows 7, 1 GB recommended for Windows Vista, Windows 7,  
Windows 10  
Use an internal hard disk.*2  
Windows 10  
Use an internal hard disk.*2  
Hard disk area  
Printer  
Max. approx. 100 MB required per day.  
Max. approx. 500 MB required per day.  
Use a printer for Windows. The programs use Standard System Fonts used in Windows.  
Use a printer driver for Standard System Fonts.  
Windows supported CD drive is used to install the software program.  
CD drive  
Card reader drive  
Used with devices which save data in a CF Card  
RS-232-C port (COM1 through COM5) supported LAN card by Windows  
LAN card  
Communication port  
*1. The 73VR1100 or the 73VR21x cannot be used in High Speed Mode.  
*2. External (e.g. SCSI) devices may impair appropriate performance.  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 5/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
EXTERNAL VIEW  
FRONT VIEW  
(1) Touch Panel Screen  
(2) Front Cover  
(3) CF Card Slot  
(7) USB Connector  
(4) Eject Button  
(6) CF Card Access Indicator LED  
(5) Reset Button  
REAR VIEW  
(8) RS-485 Terminal Block  
(14) Alarm Output Terminal  
(9) LAN Port  
ALM ALM  
U V  
(+) ()  
+
RUN  
+
RUN FG  
(
10) RUN Output Indicator LED  
11) Power Indicator LED  
12) Power Input Terminal  
13) RUN Output Terminal  
(
(
(
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 6/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
COMMUNICATION CABLE CONNECTIONS  
R3-NM1, R5-NM1, R7M  
R3-NM1  
R5-NM1  
R7M  
R3-NM1  
R5-NM1  
R7M  
73VR1100  
RS-485  
RS-485  
Terminator  
DA  
DA  
DB  
DA  
Terminator  
DB  
DB  
1
*
TR  
DG  
FG  
DG  
SLD  
FG  
DG  
SLD  
FG  
2
*
FG  
PC RECORDER, 53U  
73VR1100  
Terminator  
PC Recorder  
53U  
PC Recorder  
53U  
RS-485  
RS-485  
DA  
DB  
TR  
DG  
FG  
T1  
T2  
T3  
T4  
T1  
T2  
1
1
*
*
T3  
T4  
2
*
FG  
2
*
FG  
*1. Internal terminating resistor is used when the device is at the extreme end of a transmission line.  
*2. Install shield cables to all sections and ground them at a single point.  
CONNECTION DIAGRAM  
Note: In order to improve EMC performance, bond the FG terminal to ground.  
Caution: FG terminal is NOT a protective conductor terminal.  
Ethernet  
10BASE-T / 100BASE-TX  
RJ-45 MODULAR JACK  
DA  
DB  
TR  
DG  
FG  
*
To I/O Devices  
USB  
RUN +  
RUN –  
ALM +  
ALM –  
U (+)  
POWER  
V (–)  
FG  
*Short across these terminals when the device is at the extreme end of a transmission line.  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 7/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
EXTERNAL DIMENSIONS unit: mm [inch]  
· Panel mount type  
136.5 (5.37)  
133 (5.24)  
151.5 (5.96)  
144 (5.67)  
29.2  
2 to 26 panel thickness  
(.08 to 1.02)  
(1.15)  
Attach the mounting bracket either on the top/bottom or on the sides.  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 8/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
· Desktop type  
136.5 (5.37)  
144 (5.67)  
133 (5.24)  
29.2  
(1.15)  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 9/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
PANEL CUTOUT (unit: mm)  
Usable panel thickness: 2 – 26 mm (0.08” – 1.02”)  
SINGLE MOUNTING  
VERTICAL CLUSTERED MOUNTING (max. 3 units)  
137+2  
137+2  
0
0
L+2 (mm)  
Number  
0
2
3
282  
426  
4
570  
175 min  
5
714  
6
858  
HORIZONTAL CLUSTERED MOUNTING  
7
1002  
1146  
1290  
1434  
8
9
10  
n
(114  
× n) – 6  
L +2  
Notes  
0
1. Dimensional tolerance 3ꢀ unless otꢁerꢂise sꢃeciꢄieꢅ.  
( 0.3 mm ꢄor < 10 mm)  
2. Desktoꢃ tyꢃe cannot be mounteꢅ on a ꢃanel surꢄace.  
one 72EM2-M4 station.  
SOFTWARE FUNCTIONS  
NUMBER OF INPUT PEN POINTS  
High speed mode: 64 points  
RS-485: 15 nodes  
DATA STORING METHOD  
Normal: Recording is manually initiated and stopped. Data  
is continuously stored while the recording is on.  
Auto: Recording is automatically initiated and stopped at a  
predefined time.  
Normal mode: 128 points  
Function pen points are included in the above figures.  
TYPE OF I/O DEVICES  
High speed mode: R3-NE1  
Event recording: The recorder detects an external event by  
trigger signal, and stores preset number of samples (max.  
1200 respectively) before and after the moment of event.  
Remote trigger: Data is automatically recorded while the  
external trigger condition (input) is true.  
STORING RATE  
Normal mode: R1M-GH2, R1M-J3, R1M-A1, R1M-D1, R1M-P4,  
R1MS-GH3, R2M-2G3, R2M-2H3, RZMS-U9, R3-NE1, R3-NM1,  
R5-NE1, R5-NM1, R7E, R7M, 53U, IT60RE, IT40SRE, IT50SRE,  
IT60SRE  
NUMBER OF I/O DEVICES  
Ethernet  
High speed mode: 100 msec.  
High speed mode: 1 station  
Normal mode: 500 msec., 1, 2, 5, 10 seconds, 1 minute, 10  
Normal mode: 2 stations; Max. 15 nodes are connectable to  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 10/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
minutes (Actual storing rate depends upon the number of  
I/O devices. Contact M-System for more information.)  
[Example] Max. number of I/O devices that ensures 500  
msec. storing intervals under the following conditions:  
Data cycle priority on alarm, RS-485 connection, no trigger  
or alarm setting  
Peak (minimum) hold (tracking decreasing signal)  
F value: F value  
Anemoscope (16 directions)  
Alarm: Alarm trip can be programmed for calculated results.  
DATA DISPLAY FUNCTIONS  
• Trend View  
R1M-GH2: 10  
Chart direction: Perpendicular or horizontal  
Number of pens displayed: 2, 4, 6, 8 per view  
Number of display views: 4  
RZMS-U9: 2  
R3-NE1: 1 (128 channels, analog input only)  
DATA STORAGE  
Chart speed:(Chart speed is described as number of pixels  
to plot single data sample.)(pixel(s)/samples)  
4, 1, 1/5, 1/32  
Data file: Stores momentary values in the storing rate and  
their calculation result.  
Alarm history file: Records time index information when  
alarms are triggered and reset.  
1/160, 1/480 or 1/960 (Not selectable with 100 msec.  
storing rate)  
Oldest data is overwritten with new data when the number  
of records reaches its limit.  
Display rate:(Common setting to all views)  
1, 2 or 5 sec.  
Comment history file: Records comments written in trend  
views with time index. Oldest data is overwritten with new  
data when the number of records reaches 1000 files.  
Configuration file: Stores the 73VR1100 setting.  
File format: Binary  
Pen thickness: Normal and wide  
Digital indicator: Shows momentary value.  
Alarm indicator: Shows alarm status of the channels  
displayed on the screen.  
Comment: Shows comments entered manually.  
Scale: Linear and square root; Switchable to the engineering  
unit scale.  
Oldest measured data is overwritten with new data or data  
recording is stopped when the card memory is full.  
ALARM  
• Bargraph View  
• Analog Alarm  
Bargraph direction: Perpendicular or horizontal  
Number of pens displayed: 2, 4, 6, 8 per view  
Number of display views: 4  
Alarm setpoints: Max. 4 points per channel  
Alarm type: High / Low  
Deadband: Set in engineering unit values  
Output: Remote output devices  
Display rate:(Common setting to all views)  
1, 2 or 5 sec.  
• Discrete Alarm  
Digital indicator: Shows momentary value.  
Alarm indicator: Shows alarm status of the channels  
displayed on the screen.  
Alarm type: ON / OFF  
Delay time: Selectable  
Output: Remote output devices  
Scale: Linear and square root;  
• Data Storage: Trigger time, reset time, pen number and  
tag name, alarm message  
Switchable to the engineering unit scale.  
• Overview  
Number of stored alarm events: Depends upon the CF Card  
capacity.  
Number of pens displayed: 2, 4, 6, 8, 16 per view  
Number of display views: 64  
128 MB: 250 events  
Display rate:(Common setting to all views)  
1, 2, or 5 sec.  
256 MB: 500 events  
512 MB or 1 GB: 1000 events  
Alarm indicator: Shows alarm status and date/time of the  
last alarm trip and reset for the channels displayed on the  
screen.  
CALCULATION FUNCTIONS  
Function pen points  
High speed mode: 32 points  
• Graphic View  
Normal mode: 32 or 64 points selectable  
Operations  
Number of display views: 2  
Display rate:(Common setting to all views)  
1, 2 or 5 sec.  
Arithmetic: Addition/subtraction, Multiplication, Division  
Logical: AND, OR, NOT, XOR  
Background image file format: .bmp  
Background image size: 320 by 240 pixels  
Background image color: 256  
Mathematical: Square root extractor, Power  
Accumulation: Analog accumulation, Pulse accumulation  
(per time unit)  
Number of components displayed: Max. 64 per view  
• Retrieve View: Shows data stored in the CF Card.  
Number of pens displayed: 2, 4, 6, 8 per view  
Filter: Moving average, First order lag  
Hold: Peak (maximum) hold (tracking increasing signal),  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 11/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
Number of display views: 4  
Supported Function Codes  
CODE NAME  
Data search: Scrolling the chart, specifying a specific time  
index, or searching by max./min. values.  
• Alarm History View: Shows data stored in the alarm  
history file.  
FUNCTION  
01  
02  
04  
11  
Read Coil Status  
Reads DO  
Read Input Status  
Reads DI  
Read Input Register  
Reads Input Register  
Fetch Communication  
Event Counter  
Reads Status Word and  
Event Counter from  
Comm. Event Counter  
Number of displayed alarm events: 16  
Number of display views: 1  
Display update: Automatically updated by a new event  
Data search: Scrolling the view or specifying a specific time  
index.  
Exception Response  
CODE NAME  
FUNCTION  
Jump: Scroll the view to an alarm event to show the relevant  
data on Retrieve View.  
01  
02  
Illegal Function  
Function Not supported  
Illegal Data Address  
Speci!ed address does  
not exist  
• Comment History View: Shows data stored in the  
comment history file.  
Supported Function Codes  
Number of displayed alarm events: 16  
Number of display views: 1  
Data storing rate 100 msec.  
ADDR. TYPE NAME  
Data search: Scrolling the view or specifying a specific time  
index.  
Coil (0X)  
1
2
3
Discrete output (pen 1, relay 1)  
Discrete output (pen 1, relay 2)  
Jump: Scroll the view to a comment to show the relevant  
data on Retrieve View.  
Discrete output (pen 1, relay 3)  
(Unused with discrete alarm)  
ETHERNET COMMUNICATION  
4
Discrete output (pen 1, relay 4)  
(Unused with discrete alarm)  
Monitoring data and setup of the 73VR1100 is possible on  
the PC connected via Ethernet.  
:
:
255  
Discrete output (pen 64, relay 3)  
(Unused with discrete alarm)  
• Dedicated Protocol  
Real time communication: Transmits specific data to a host  
PC installed with the PC Recorder Software (model:  
MSR128). Max. 2 hosts.  
256  
257  
Discrete output (pen 64, relay 4)  
(Unused with discrete alarm)  
Discrete output  
(alarm output terminal)  
FTP communication: Transmits data stored in the CF Card  
using the FTP protocol to a host PC by the 73VR Data Viewer  
(model: 73VRWV) installed in it. Data can be transmitted  
even during recording.  
Input  
Status (1X)  
1 thr. 64  
Input or function data  
(discrete)  
Input  
Register (3X)  
1 thr.  
128  
I or Input or function data  
(analog)  
F
Download, Upload: Software configurations created on the  
73VR1100 Configuration Builder (model: 73VR11BLD) can  
be downloaded to the 73VR1100. The configuration set up  
on the 73VR1100 can be uploaded and displayed on the  
73VR11BLD.  
Data storing rate 500 msec.  
ADDR. TYPE NAME  
Coil (0X)  
1
2
3
Discrete output (pen 1, relay 1)  
Discrete output (pen 1, relay 2)  
Discrete output (pen 1, relay 3)  
(Unused with discrete alarm)  
• Modbus Protocol  
Protocol: Modbus/TCP  
4
Discrete output (pen 1, relay 4)  
(Unused with discrete alarm)  
Port No.: 502 (fixed)  
IP address: Set on the recorder  
:
:
Subnet mask: Set on the recorder  
511  
Discrete output (pen 128, relay 3)  
(Unused with discrete alarm)  
Default gateway: Set on the recorder  
Max. number of 73VR1100 connected simultaneously: 2  
512  
513  
Discrete output (pen 128, relay 4)  
(Unused with discrete alarm)  
Discrete output  
(alarm output terminal)  
Input  
Status (1X)  
1 thr.  
128  
Input or function data  
(discrete)  
Input  
Register (3X)  
1 thr.  
256  
I or Input or function data  
(analog)  
F
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 12/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
OTHER FUNCTIONS  
• R3 Series Remote I/O  
• Operation Lockout  
SIGNAL TYPE  
MODELS  
With a password setting, unauthorized operations on the  
Trend View, Bargraph View and Overview can be locked out.  
• Data File Used Volume Information  
A bargraph with % indication is provided on the screen to  
show how much percent of the data file memory has been  
used up.  
DC voltage input  
R3-SV4, R3-SV4A, R3-SV4B,  
R3-SV4C, R3(Y)-SV8, R3-SV8A,  
R3-SV8B, R3-SV8C, R3(S/Y)-SV8N,  
R3-SV16N, R3Y-SV16  
DC current input  
R3-SS4, R3(Y)-SS8, R3(S/Y)-SS8N,  
R3(Y)-SS16N  
Thermocouple input R3-TS4, R3-TS8  
0 – 49 % used: Green bargraph  
RTD input  
R3-RS4, R3(S)-RS4A, R3(Y)-RS8,  
50 – 79 % used: Amber bargraph  
R3-RS8A, R3-RS8B  
R3-US4  
80 – 100 % used: Red bargraph  
Universal input  
Discrete input  
• Hot Swapping of the CF Card  
R3(S/Y)-DA16, R3(Y)-DA16A,  
The CF Card is hot swappable: removable during data  
recording. However, there may be a slight disturbance in  
storing rate when the card is inserted.  
• Screen Saver  
R3-DA16B, R3-DA32A, R3-DA64A  
Discrete output  
R3(Y)-DC16, R3-DC16A, R3-DC16B,  
R3-DC16C, R3-DC32A, R3-DC32C,  
R3-DC64A, R3-DC64C  
Discrete I/O  
R3(S)-DAC16*, R3(S)-DAC16A*  
The backlight is automatically turned off if the screen is  
untouched for a certain time period.  
• Writing/Reading Setting  
4 – 20mA input with R3(Y)-DS4, R3-DS8N, R3(Y)-DS8N  
excitation supply  
Potentiometer input R3-MS4, R3(Y)-MS8  
The recorder’s present setting can be stored in a USB flash-  
memory. Setting stored in the memory can be read in to the  
73VR1100.  
CT input  
R3-CT4  
AC current input with R3-CT4A**, R3-CT4B**, R3-CT4C,  
clamp-on current  
sensor  
R3-CT8A**, R3-CT8B**, R3-CT8C  
SELECTABLE REMOTE I/O MODULES  
PT input  
R3-PT4  
• PC Recorder (R1, R2, RZ) Series  
Zero-phase current R3-CZ4  
input  
SIGNAL TYPE  
MODELS  
DC voltage input  
R1M-GH2, R1MS-GH3, R2M-2G3,  
RZMS-U9  
AC power input  
R3-WT4, R3-WT4A, R3-WT4B,  
R3-WTU  
R3-PA4  
Thermocouple input  
R1M-GH2 R1MS-GH3, R2M-2H3,  
RZMS-U9  
High speed pulse  
input  
DC current input  
RTD input  
R1M-GH2 R1MS-GH3, RZMS-U9  
R1M-J3, RZMS-U9  
R1M-J3, RZMS-U9  
R1M-A1  
Speed/position input R3-PA2  
Totalized pulse input R3-PA4A, R3-PA4B, R3(Y)-PA16,  
R3(S)-PA8  
Potentiometer input  
Contact input  
Strain gauge input  
Alarm  
R3-LC2  
Contact output  
Pulse input  
R1M-D1  
R3-AD4, R3-AR4, R3-AS4, R3-AS8,  
R3-AT4, R3-AV4, R3-AV8  
R1M-P4  
Totalized pulse input  
R1M-P4, R1M-A1  
Gateway  
R3-GC1, R3-GD1, R3-GE1,  
R3-GFL1, R3-GM1  
*
Only continuous output mode is available.  
** Data range must be setup with the PC Con!gurator Software  
R3CON and the dedicated cable.  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 13/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
• R5 Series Remote I/O  
• ETHERNET Tower Light  
SIGNAL TYPE  
DC voltage input  
DC current input  
Thermocouple input  
RTD input  
MODELS  
SIGNAL TYPE  
Discrete output  
MODELS  
R5-SV, R5T-SV  
IT60RE, IT40SRE, IT50SRE,  
IT60SRE  
R5-SS, R5T-SS  
R5-TS, R5T-TS  
R5-RS, R5T-RS  
Discrete input  
R5-DA4, R5T-DA4, R5-DA16  
R5-DC4, R5T-DC4, R5-DC16  
R5-DS, R5T-DS  
Discrete output  
4 – 20 mA input with  
excitation supply  
Potentiometer input  
CT input  
R5-MS  
R5T-CT  
AC current input with  
clamp-on current sensor  
PT input  
R5T-CTA*, R5T-CTB*  
R5T-PT  
* Data range must be setup with the PC Con!gurator Software  
R5CON and the dedicated cable.  
• R7M Series Remote I/O*  
SIGNAL TYPE  
DC voltage/current input  
Thermocouple input  
RTD input  
MODELS  
R7M-SV4  
R7M-TS4  
R7M-RS4  
Potentiometer input  
CT input  
R7M-MS4  
R7M-CT4E  
R7M-DA16  
Discrete input  
Discrete output  
R7M-DC16A, R7M-DC16B,  
R7M-DC8C  
Discrete input (Extension) R7M-EA8, R7M-EA16  
Discrete output (Extension) R7M-EC8A, R7M-EC8B,  
R7M-EC16A, R7M-EC16B  
* Must be setup with R7X Con!gurator Software and the dedi-  
cated cable.  
• R7E Series Remote I/O  
SIGNAL TYPE  
DC voltage/current input  
Thermocouple input  
RTD input  
MODELS  
R7E-SV4  
R7E-TS4  
R7E-RS4  
Potentiometer input  
CT input  
R7E-MS4  
R7E-CT4E*  
R7E-DA16  
Discrete input  
Discrete output  
R7E-DC16A, R7E-DC16B  
Discrete input (Extension) R7E-EA8, R7E-EA16  
Discrete output (Extension) R7E-EC8A, R7E-EC8B,  
R7E-EC16A, R7E-EC16B  
* Must be setup with R7X Con!gurator Software and the dedi-  
cated cable.  
• Power Multimeter  
TYPE  
MODELS  
Power multimeter  
53U*  
* Choose ‘Modbus’ option. Only 1 DO can be used for alarm  
output.  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 14/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
STORABLE TIME DURATION IN 1GB CF CARD  
STORING  
RATE  
APPROXIMATE TIME DURATION  
32 ch input  
8 days, 8 hours  
8 ch input  
27 days, 16 hours  
138 days  
277 days  
7 years, 222 days  
10 years minimum  
16 ch input  
15 days, 8 hour  
77 days  
64 ch input  
4 days, 8 hours  
128 ch input  
---  
14 days  
28 days, 8 hours  
213 days  
3 years, 172 days  
0.1 seconds  
0.5 seconds  
1 second  
10 seconds  
1 minute  
40 days  
20 days, 16 hours  
42 days  
1 years, 55 days  
6 years, 335 days  
154 days  
4 years, 83 days  
10 years minimum  
81 days, 16 hours  
2 years, 86 days  
10 years minimum  
--- : Not Applicable  
Note 1: Data are calculated ones, and thus not guaranteed.  
Note 2: Assuming 4 bytes per data per channel.  
Note 3: A year is calculated as 365 days.  
SYSTEM CONFIGURATION EXAMPLES  
R1M, R2M, RZMS  
[Example 1]  
Paperless Recorder  
(model: 73VR1100)  
RS-485  
RS-485  
PC Recorder  
(model: R1M-GH  
or R1MS-GH3)  
PC Recorder  
(model: R1M-A1)  
PC Recorder  
(model: R1M-D1)  
PC Recorder  
(model: R1M-P4)  
PC Recorder  
(model: RZMS-U9)  
RS-232-C  
Interlink / Reverse  
Cable  
PC Recorder  
(model: R2M)  
[Example 2]  
Paperless Recorder  
(model: 73VR1100)  
Ethernet  
100 Mbps  
Hub / Switch  
Ethernet  
Communication Adaptor  
(model: 72EM2-M4)  
Communication Adaptor  
(model: 72EM2-M4)  
ETHERNET  
ETHERNET  
RS-485  
RS-485  
RUN  
RUN  
SEND  
FIELD  
SEND  
FIELD  
CNFG  
CNFG  
RS-485  
RS-485  
PC Recorder PC Recorder  
(model: R1M-GH) (model: R1M-D1)  
PC Recorder  
(model: R1M-A1)  
PC Recorder PC Recorder  
(model: RZMS-U9) (model: RZMS-U9)  
PC Recorder  
(model: RZMS-U9)  
Note 1: Use a dedicated network for the 73VR1100 and its input devices.  
Note 2: The sampling rate depends upon the number of devices to be connected.  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 15/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
R3, R5 SERIES  
Paperless Recorder  
(model: 73VR1100)  
Paperless Recorder  
(model: 73VR1100)  
RS-485  
Ethernet  
100 Mbps  
Hub / Switch  
Ethernet  
I/O Modules  
Network Module  
(model: R3-NM1, R5-NM1)  
I/O Modules  
Network Module  
(model: R3-NE1, R5-NE1)  
Note 1: Use a dedicated network for the 73VR1100 and its input devices.  
Note 2: The sampling rate depends upon the number of devices to be connected for the R3 series.  
Note 3: Use of a switch/hub via straight type cables is recommended to connect the R3-NE1 or the R5-NE1 to the 73VR1100.  
R7E  
Paperless Recorder  
(model: 73VR1100)  
Ethernet  
Hub / Switch  
Ethernet  
Modbus I/O Module  
(model: R7E)  
Modbus I/O Module  
(model: R7E)  
R7M  
Paperless Recorder  
(model: 73VR1100)  
RS-485  
Modbus I/O Module  
(model: R7M)  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 16/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
53U  
Paperless Recorder  
(model: 73VR1100)  
RS-485  
RS-485 (Modbus RTU)  
Multi Power Monitor  
(model: 53U)  
IT60RE (R3 applied on input units)  
Paperless Recorder  
(model: 73VR1100)  
Ethernet  
Hub  
Ethernet  
Interface Module  
(Model: R3-NE1)  
Tower Light  
(Model: IT60RE)  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 17/18  
https://www.m-system.co.jp/  
MODEL: 73VR1100  
MSR128  
• I/O devices connected to RS-485  
• Transferring data from the CF Card  
PC Recorder Software  
(model: MSR128)  
PC Recorder Software  
(model: MSR128)  
Card Reader  
CF Card  
Ethernet  
100 Mbps  
Hub / Switch  
Paperless Recorder  
(model: 73VR1100)  
Ethernet  
RS-485  
Paperless Recorder  
(model: 73VR1100)  
PC Recorder  
(model: R1M-GH)  
PC Recorder  
(model: R1M-D1)  
PC Recorder  
(model: R1M-A1)  
RS-485  
PC Recorder PC Recorder  
(model: R1M-GH) (model: R1M-D1)  
PC Recorder  
(model: R1M-A1)  
• I/O devices connected to Ethernet  
PC Recorder Software  
(model: MSR128)  
Ethernet  
100 Mbps  
Hub / Switch  
Ethernet  
Paperless Recorder  
(model: 73VR1100)  
I/O Modules  
(model: R3-NE1, R5-NE1)  
Network Module  
Note 1: Use a dedicated network for the 73VR1100 and its input devices.  
Note 2: Use of a hub/switch via straight cables is recommended to connect the 73VR1100 to the PC.  
Note 3: The storing intervals of 100 msec. and 200 msec. are not applicable to the above configuration.  
Specifications are subject to change without notice.  
73VR1100 SPECIFICATIONS  
ES-7399 Rev.24 Page 18/18  
https://www.m-system.co.jp/  

相关型号:

73VR1100-E-M2/Q

Paperless Recording System
MSYSTEM

73VR1100-E-R

Paperless Recording System
MSYSTEM

73VR1100-E-R/Q

Paperless Recording System
MSYSTEM

73VR1100-N-M2

Paperless Recording System
MSYSTEM

73VR1100-N-M2/Q

Paperless Recording System
MSYSTEM

73VR1100-N-R

Paperless Recording System
MSYSTEM

73VR1100-N-R/Q

Paperless Recording System
MSYSTEM

73VR2102

Paperless Recording System
MSYSTEM

73VR2102-E-M2

Paperless Recording System
MSYSTEM

73VR2102-E-M2/Q

Paperless Recording System
MSYSTEM

73VR2102-E-R

Paperless Recording System
MSYSTEM

73VR2102-E-R/Q

Paperless Recording System
MSYSTEM