CVR1-HH-M2/CE 概述
Plug-in Signal Conditioners M-UNIT
CVR1-HH-M2/CE 数据手册
通过下载CVR1-HH-M2/CE数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: CVR1
D: 200 Ω
E: 500 Ω
F: 2 kΩ
Plug-in Signal Conditioners M-UNIT
DC/POTENTIOMETER CONVERTER
Functions & Features
G: 5 kΩ
H: 10 kΩ
I: 20 kΩ
J: 50 kΩ
K: 100 kΩ
• Converting a DC input into a potentiometer resistance
• Permissible wattage 1 W
Typical Applications
• Remote setting for inverters
[3] POWER INPUT
AC Power
• Remote setting for Honeywell's Modutrol motors
• Remote setting for various instruments with
potentiometer settings
M2: 100 – 240 V AC (Operational voltage range 90 – 264 V,
47 – 66 Hz)
K: 85 – 132 V AC
50
(1.97)
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
(CE not available)
DC Power
80
R: 24 V DC
(3.15)
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
136
(5.35)
[4] OPTIONS
Standards & Approvals
blank: Without CE
/CE: CE marking
mm (inch)
MODEL: CVR1–[1][2]–[3][4]
GENERAL SPECIFICATIONS
Construction: Plug-in
ORDERING INFORMATION
• Code number: CVR1-[1][2]-[3][4]
Specify a code from below for each of [1] through [4].
(e.g. CVR1-AH-M2/CE)
Connection: M3.5 screw terminals
Screw terminal: Chromated steel
Housing material: Flame-resistant resin (black)
Deadband: Automatically adjusted from 0.1 to 2 % of span
to avoid hunting
[1] INPUT
Current
Output delay: Approx. 0.5 sec. from an input change to the
output in order to protect the internal motor; when the input
continuously or repeatedly changes, there is approx. 3-sec.
delay after the output becomes steady and then resumes
changing.
A: 4 – 20 mA DC (Input resistance 250 Ω)
B: 2 – 10 mA DC (Input resistance 500 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 50 Ω)
E: 0 – 16 mA DC (Input resistance 62.5 Ω)
F: 0 – 10 mA DC (Input resistance 100 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
Voltage
Isolation
Power input code K, R:
Input to to output to power
Power input code M2:
Input to to output to power to FE
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
Zero adjustment: -20 to +20 % (input) (front)
Span adjustment: 80 to 120 % (input) (front)
INPUT SPECIFICATIONS
■ DC Current:
[2] OUTPUT
A: 135 Ω
Shunt resistor attached to the input terminals (0.5 W)
B: 1 kΩ
C: 100 Ω
CVR1 SPECIFICATIONS
ES-1554 Rev.9 Page 1/4
https://www.m-system.co.jp/
MODEL: CVR1
RoHS Directive
OUTPUT SPECIFICATIONS
Output: 3-wire potentiometer
Operational range: Approx. 3 – 97 % of total resistance
Maximum permissible wattage: 1 W (across the terminals 1
– 3)
Mechanical life: 150,000 cycles
INSTALLATION
Power consumption
•AC: Approx. 4 VA
•DC: Approx. 3 W
Operating temperature: -5 to +40°C (23 to 104°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 450 g (0.99 lb)
PERFORMANCE in percentage of total resistance
Minimum deadband: ±0.2 % (when input signal has been
steady for 2 minutes)
Linearity: ±1 % (includes nonlinearity, hysteresis and
deadband)
Note: The deadband is automatically adjusted.
The deadband broadens when the input-signal changes
frequently.
Slidewire accuracy: ±5 % of rating
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
Temp. coefficient of slidewire: ±50 PPM/°C (±28 PPM/°F)
Response time: Approx. 5 sec. (0 – 100 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength
Power input code K, R:
1000 V AC @ 1 minute (input to output)
2000 V AC @ 1 minute (input or output to power)
Power input code M2:
500 V AC @ 1 minute (input to FE)
1000 V AC @ 1 minute (input or FE to output)
2000 V AC @ 1 minute (input or output or FE to power)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
CVR1 SPECIFICATIONS
ES-1554 Rev.9 Page 2/4
https://www.m-system.co.jp/
MODEL: CVR1
EXTERNAL DIMENSIONS unit: mm [inch]
CLAMP
(top & bottom)
7.8 (.31)
DIN RAIL
35mm wide
8
9
7
6
5
4
2–
4.5 (.18) dia.
MTG HOLE
25 (.98) deep
3
2
10 11
1
11
–M3.5
SCREW
50 (1.97)
107 (4.21)
136 (5.35)
40 (1.57)
50 (1.97)
[3.3 (.13)]
• When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm [inch]
INPUT RESISTOR
(model: REM)
8
7
6
5
4
9
3
2
10 11
1
Input shunt resistor attached
for current input.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
POTENTIOMETER
Reference
Volt. Generetor
max.
OUTPUT
min.
3
2
1
3
2
1
Z
S
MOTOR
Input
Circuit
Servo
Amplifier
+
–
M
M
5
6
1
*
INPUT
R
9
U(+)
V(–)
10
11
7
8
4
POWER
2
*
FE
Base Socket
*1. Input shunt resistor attached for current input.
*2. Only for power Input code M2.
In order to improve EMC performance, bond the FE terminal to ground.
Caution: This terminal is NOT a protective conductor terminal.
CVR1 SPECIFICATIONS
ES-1554 Rev.9 Page 3/4
https://www.m-system.co.jp/
MODEL: CVR1
Specifications are subject to change without notice.
CVR1 SPECIFICATIONS
ES-1554 Rev.9 Page 4/4
https://www.m-system.co.jp/
CVR1-HH-M2/CE 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
CVR1-HH-R | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HH-R/CE | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HJ-K | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HJ-K/CE | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HJ-M2 | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HJ-M2/CE | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HJ-R | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HJ-R/CE | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HK-K | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
CVR1-HK-K/CE | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 |
CVR1-HH-M2/CE 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8