DAL4-1-M2 [MSYSTEM]

Multiplex Transmission System;
DAL4-1-M2
型号: DAL4-1-M2
厂家: M-SYSTEM    M-SYSTEM
描述:

Multiplex Transmission System

文件: 总6页 (文件大小:153K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: DAL4  
Multiplex Transmission System  
RELATED PRODUCTS  
• Standard multi-transmission unit (model: DLA1)  
• Remote I/O unit (model: DLA2)  
REPEATER  
(SIN-NET, M-Bus use)  
• Multi-transmission module (model: 22LA1)  
• SIN-NET interface module (model: D3-NS1)  
• Telemetering interface module (model: D3-NS2)  
• Remote I/O interface module (model: D3-NS3)  
• Lightning surge protector (model: MDP-DM3)  
Functions & Features  
• Extending No. of field devices and transmission distance  
for DLA1, DLA2  
• Branching  
• Transmission media conversion (twisted-pair from/to fiber  
optics)  
APPLICABLE NETWORK  
• Repeater circuit incorporated in each port  
SIN-NET, M-Bus  
Typical Applications  
GENERAL SPECIFICATIONS  
Construction: Stand-alone; terminal access at the front  
Connection  
• Exceeding 1 kilometer (3280 ft) distance with DLA1 or  
DLA2  
• Using more than 16 DLA1 or DLA2 units  
Twisted-pair cable & power input: M3.5 screw terminals  
(torque 0.8 N·m)  
75  
(2.95)  
Optical fiber: Connector  
Screw terminal: Nickel-plated steel  
Housing material: Flame-resistant resin (black)  
Isolation: PORT-A to PORT-B to PORT-C to power to FG  
75  
(2.95)  
COMMUNICATION  
TWISTED-PAIR CABLE  
112  
(4.41)  
mm (inch)  
Cable: CPEV-0.9 dia.  
Transmission Distance: 1 kilometer max. with 16 field units;  
2 kilometers max. between two DAL4  
FIBER OPTICS CABLE  
MODEL: DAL4-[1]-[2]  
• PCF  
Transmission distance: 1 kilometer max.  
Link: JIS F07 connector  
ORDERING INFORMATION  
• Code number: DAL4–[1]-[2]  
Applicable fiber HC-20/07 (SUMITOMO):  
Core/clad dia. 200/230 µm  
Max. loss 11 dB*1  
Specify a code from below for each of [1] and [2].  
(e.g. DAL4-1-M2)  
• GI-850 nm (DAL4-5)  
Transmission distance: 2.5 kilometers max.  
Connector: JIS F01 connector  
Applicable fiber:  
[1] CABLE & PORT TYPE  
1: Twisted-pair cable, 3 ports  
2: Fiber optics (PCF), 2 ports + Twisted-pair cable, 1 port  
5: Fiber optics (GI-850 nm), 1 port + Twisted-pair cable, 1 port  
7: Fiber optics (GI-850 nm), 1 port + Twisted-pair cable, 1 port  
Core/clad dia. 50/125 µm  
Max. loss 7 dB*1  
• GI-850 nm (DAL4-7)  
Transmission distance: 4 kilometers max.  
Connector: JIS F01 connector  
Applicable fiber:  
[2] POWER INPUT  
AC Power  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
Core/clad dia. 50/125 µm  
Max. loss 12 dB*1  
47 – 66 Hz)  
DC Power  
*1. Total of connection and transmission loss.  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
DAL4 SPECIFICATIONS  
ES-6782 Rev.2 Page 1/6  
http://www.m-system.co.jp/  
MODEL: DAL4  
INSTALLATION  
Power consumption  
AC: Approx. 11 VA  
DC: Approx. 250 mA  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 300 g (0.66 lb)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(PORT-A to PORT-B to PORT-C to power to FG)  
DAL4 SPECIFICATIONS  
ES-6782 Rev.2 Page 2/6  
http://www.m-system.co.jp/  
MODEL: DAL4  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
■DAL4-1  
■DAL4-2  
■DAL4-5, 7  
2–5.8 (.23) dia. or  
2–4.8 (.18) dia.  
MTG HOLE  
16–M3.5  
SCREW  
8 (.31)  
8 (.31) deep  
DIN RAIL  
35mm wide  
TERMINAL  
COVER  
1
9
2
3
4
5
6
7 8  
10 11 12 13 14 15 16  
112 (4.41)  
[3.3 (.13)]  
75 (2.95)  
•When mounting, no extra space is needed between units.  
2–5.8 (.23) dia. or  
2–4.8 (.18) dia.  
MTG HOLE  
16–M3.5  
SCREW  
8 (.31)  
8 (.31) deep  
DIN RAIL  
35mm wide  
TERMINAL  
COVER  
1
9
2
3
4
5
6
7 8  
10 11 12 13 14 15 16  
112 (4.41)  
[3.3 (.13)]  
75 (2.95)  
•When mounting, no extra space is needed between units.  
2–5.8 (.23) dia. or  
2–4.8 (.18) dia.  
MTG HOLE  
16–M3.5  
SCREW  
8 (.31)  
8 (.31) deep  
DIN RAIL  
35mm wide  
TERMINAL  
COVER  
1
9
2
3
4
5
6
7 8  
TXD  
RXD  
10 11 12 13 14 15 16  
112 (4.41)  
[3.3 (.13)]  
75 (2.95)  
•When mounting, no extra space is needed between units.  
DAL4 SPECIFICATIONS  
ES-6782 Rev.2 Page 3/6  
http://www.m-system.co.jp/  
MODEL: DAL4  
MOUNTING REQUIREMENTS unit: mm (inch)  
M5 SCREWS  
M4 SCREWS  
60 (2.36)  
60 (2.36)  
2–M5  
2–M4  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
DAL4-1  
PORT-A  
Shielded  
Twisted-pair Cable  
PORT-C  
Shielded  
Twisted-pair Cable  
+
Isolation  
1
2
3
4
5
6
7
8
Transceiver  
13  
14  
15  
16  
11  
Transceiver  
+
Terminating  
Resistor  
Terminating  
Resistor  
*Jumper Pin  
Repeater  
Jumper Pin*  
PORT-B  
Shielded  
Twisted-pair Cable  
**  
Isolation  
**  
Transceiver  
+
12  
9
FG***  
Terminating  
Resistor  
*Jumper Pin  
U(+)  
POWER  
V(–)  
**  
10  
DAL4-2  
FIBER OPTICS  
PORT-C  
Shielded  
Twisted-pair Cable  
+
LINK A  
LINK B  
Transceiver  
13  
14  
15  
16  
11  
12  
9
Repeater  
Terminating  
Resistor  
Jumper Pin*  
**  
FIBER OPTICS  
FG***  
U(+)  
POWER  
V(–)  
10  
DAL4-5, 7  
FIBER OPTICS  
FIBER OPTICS  
PORT-C  
Shielded  
Twisted-pair Cable  
+
PORT-A TXD  
PORT-A RXD  
13  
14  
15  
16  
11  
12  
9
Repeater  
Transceiver  
Terminating  
Resistor  
Jumper Pin*  
**  
FG***  
U(+)  
POWER  
V(–)  
10  
*
When the unit is located at the end of transmission line via twisted-pair cable (= no cross-wiring),  
short across these terminals. Do not short them for the one not located at the end.  
** When the DAL4 is to be connected with the 22LA1 or DLA1 multi transmission devices,  
do not connect the shield wire to the SG (4, 8 or 16) but to the FG at the instrumentation panel.  
***Grounding the FG improves noise immunity of the power and transmission lines, and  
is a recommended practice when the DAL4 is installed where a noise is present.  
DAL4 SPECIFICATIONS  
ES-6782 Rev.2 Page 4/6  
http://www.m-system.co.jp/  
MODEL: DAL4  
LIGHTNING SURGE PROTECTION  
MULTIPLEX TRANSMISSION  
DAL4-1  
DLA1, 22LA1  
MDP-DM3  
MDP-DM3  
+
+
+
+
C
B
A
3
2
1
1
2
3
4
5
6
7
8
12  
13  
14  
15  
16  
3
2
1
C
B
A
LINE  
LINE  
*
*
G
G
G
+
C
B
A
3
2
1
*
9
10  
11  
PANEL  
*Terminating resistor  
Notes  
• Be sure to use lightning surge protectors (model: MDP-DM3) on twisted-pair cables.  
• Be sure to connect the terminal No. 1 of the MDP-DM3 with SG terminal of the DAL4.  
• For connecting model DLA1 or 22LA1 with the DAL4 in the same panel, install them between the MDP-DM3 and the DAL4.  
Be sure to connect the terminal No. 1 of the MDP-DM3 with SG terminal of the DAL4.  
• Lightning surge protectors for power supply line are recommended for complete protection.  
M-BUS  
DAL4-1  
13  
DLA2, SMLM  
Shielded  
Twisted-pair Cable  
Shielded  
Twisted-pair Cable  
MDP-DM3  
MDP-DM3  
+
+
+
+
C
B
A
3
2
1
1
2
3
2
1
C
B
A
14  
15  
16  
LINE  
LINE  
*
*
3
G
G
G
SG  
SG  
4
Shielded  
Twisted-pair Cable  
+
C
B
A
3
2
1
5
6
*
7
9
8
10  
11  
12  
PANEL  
*Terminating resistor  
Notes  
• Be sure to use lightning surge protectors (model: MDP-DM3) on twisted-pair cables.  
• Be sure to connect the terminal No. 1 of the MDP-DM3 with SG terminal of the DAL4.  
• For connecting model DLA2 or SMLM with the DAL4 in the same panel, install them between the MDP-DM3 and the DAL4.  
Be sure to connect the terminal No. 1 of the MDP-DM3 with SG terminal of the DAL4.  
• Lightning surge protectors for power supply line are recommended for complete protection.  
DAL4 SPECIFICATIONS  
ES-6782 Rev.2 Page 5/6  
http://www.m-system.co.jp/  
MODEL: DAL4  
Specifications are subject to change without notice.  
DAL4 SPECIFICATIONS  
ES-6782 Rev.2 Page 6/6  
http://www.m-system.co.jp/  

相关型号:

DAL4-1-R

Multiplex Transmission System
MSYSTEM

DAL4-2-M2

Multiplex Transmission System
MSYSTEM

DAL4-2-R

Multiplex Transmission System
MSYSTEM

DAL4-5-M2

Multiplex Transmission System
MSYSTEM

DAL4-5-R

Multiplex Transmission System
MSYSTEM

DAL4-7-M2

Multiplex Transmission System
MSYSTEM

DAL4-7-R

Multiplex Transmission System
MSYSTEM

DAL5250CT17T

5.250 GHZ DIELECTRIC ANTENNA
TOKO

DAL5W5P/S81C5M40

D Subminiature Connector
AMPHENOL

DAL5W5P543A30LF

D Type Connector, 5 Contact(s), Male, Solder Terminal, M3
AMPHENOL

DAL5W5P543A40LF

D Type Connector, 5 Contact(s), Male, Solder Terminal, M3
AMPHENOL

DAL5W5P543G00LF

D Type Connector, 5 Contact(s), Male, Solder Terminal, M3
AMPHENOL