MODEL: FRTD  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
Space-saving Plug-in Signal Conditioners F-UNIT  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
J: 0 – 10 μA DC (Input resistance 1000 Ω)  
K: 0 – 100 μA DC (Input resistance 1000 Ω)  
GW: -1 – +1 mA DC (Input resistance 1000 Ω)  
FW: -10 – +10 mA DC (Input resistance 100 Ω)  
Z: Specify current (See INPUT SPECIFICATIONS)  
Voltage  
RATIO TRANSMITTER  
(output bias; thumbwheel switch adjustments)  
Functions & Features  
• Providing precise matching of DC control signals to final  
control elements in open- or closed-loop systems  
• Easy thumbwheel switch adjustments  
• Ratio adjustable from 0.1 to 3.99  
• Bias adjustable within ±99 %  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
15: 0 – 50 mV DC (Input resistance 10 kΩ min.)  
16: 0 – 60 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)  
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
• High-density mounting  
Typical Applications  
• Ratio control for air/fuel flows or for two flows  
• Gain calculation for manipulated variable from a controller  
• Large scale signal span adjustment  
26 (1.02)  
[3] OUTPUT  
Current  
100  
(3.94)  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
137  
(5.39)  
mm (inch)  
MODEL: FRTD–[1]–[2][3]–[4][5]  
ORDERING INFORMATION  
• Code number: FRTD-[1]-[2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. FRTD-S-AA-L/Q)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Special input and output ranges (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[1] OUTPUT CHARACTERISTICS  
S: Positive  
R: Negative  
[4] POWER INPUT  
AC Power  
[2] INPUT  
K: 85 – 132 V AC  
Current  
(Operational voltage range 85 – 132 V, 47 – 66 Hz)  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
A1: 4 – 20 mA DC (Input resistance 50 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
E: 0 – 16 mA DC (Input resistance 62.5 Ω)  
F: 0 – 10 mA DC (Input resistance 100 Ω)  
L: 170 – 264 V AC  
(Operational voltage range 170 – 264 V, 47 – 66 Hz)  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
FRTD SPECIFICATIONS  
ES-1485 Rev.6 Page 1/4  
http://www.m-system.co.jp/  
MODEL: FRTD  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
INPUT SPECIFICATIONS  
DC Current:  
Shunt resistor attached to the input terminals (0.5 W)  
Specify input resistance value for code Z.  
DC Voltage: -300 – +300 V DC  
Minimum span: 3 mV  
[5] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
Offset: Max. 1.5 times span  
Input resistance  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Span 3 – 10 mV : ≥ 10 kΩ  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Span ≥ 1 V : ≥ 1 MΩ  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Connection: M3.5 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max. at ≥ 0.5 V  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
INSTALLATION  
Power input  
Equation: X  
= F – K X  
where X : output (%)  
: input (%)  
K: ratio  
o
= KX  
i
+ B for positive ratio;  
AC: Approx. 4.5 VA  
X
o
i
+ B for negative ratio  
DC: 24 V approx. 70 mA  
o
110 V approx. 20 mA  
Xi  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail; Standard Rack Mounting  
Frame BX-16H available  
(0.1 – 3.99 conformance range)  
B: bias (-99 – +99 %)  
F: 100 %  
Weight: 200 g (0.44 lb)  
(factory setting: K = 1, B = 0 %)  
Ratio/bias adjustment: 3-digit thumbwheel switches  
100%  
PERFORMANCE in percentage of span  
Ratio setting accuracy: ±0.2 %  
[Examples of Positive Gain]  
2
1
1
2
3
4
5
6
K = 1  
B
B
B
B
B
B
= 50%  
= 50%  
= 0  
4
K = 0.5  
K = 2  
(at 0.1 – 3.99 conformance range)  
50  
Bias setting accuracy: ±1 %  
K = 1  
= 0  
3
5
6
K = 0.5  
K = 1  
= 0  
Accuracy: ±0.3 % (with ratio = 1, bias = 0 %)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength  
= –50%  
0
0
50  
100%  
INPUT  
100%  
[Examples of Negative Gain]  
5
1
1
2
3
4
5
6
K = 1  
B
B
B
B
B
B
= 50%  
= –50%  
= 0  
3
K = 0.5  
K = 2  
Power input code R:  
50  
1000 V AC @ 1 minute (input to output)  
2000 V AC @ 1 minute (input or output or power to ground)  
500 V AC @ 1 minute (I/O to power)  
K = 1  
= 0  
4
K = 0.5  
K = 1  
= 0  
6
2
= –50%  
0
0
50  
100%  
Power input code K, L, P:  
INPUT  
1000 V AC @ 1 minute (input to output)  
2000 V AC @ 1 minute (input or output or power to ground)  
FRTD SPECIFICATIONS  
ES-1485 Rev.6 Page 2/4  
http://www.m-system.co.jp/  
MODEL: FRTD  
1500 V AC @ 1 minute (I/O to power)  
EXTERNAL VIEW  
Zero Adj.  
Ratio Adj.  
3 9 9  
Bias Adj.  
+
9 9  
Span Adj.  
EXTERNAL DIMENSIONS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
1
2
15  
(.59)  
DIN RAIL  
35mm wide  
3
4
2–4.5 (.18)  
HOLE  
15 (.59) deep  
5
6
8–M3.5  
SCREW  
7
8
26 (1.02)  
107 (4.21)  
137 (5.39)  
26 (1.02)  
[3.3 (.13)]  
•When mounting, no extra space is needed between units.  
TERMINAL ASSIGNMENTS unit: mm (inch)  
INPUT RESISTOR  
(model: REM)  
1
2
3
4
5
6
7
8
Input shunt resistor attached  
for current input.  
FRTD SPECIFICATIONS  
ES-1485 Rev.6 Page 3/4  
http://www.m-system.co.jp/  
MODEL: FRTD  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
RATIO  
BIAS  
+
THUMBWHEEL  
SWITCHES  
3 9 9  
9 9  
Z
S
Isolation  
Low Drift  
Amplifier  
Reverser, Ratio / Bias  
Computation  
Output  
Driver  
+
1
2
3
4
5
6
7
8
+
*
INPUT  
R
OUTPUT  
POWER  
U(+)  
V(–)  
Base Socket  
*Input shunt resistor attached for current input.  
Specifications are subject to change without notice.  
FRTD SPECIFICATIONS  
ES-1485 Rev.6 Page 4/4  
http://www.m-system.co.jp/  

FRTD-S-Z3-P 相关器件

型号 制造商 描述 价格 文档
FRTD-S-Z3-R MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4-K MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4-K/Q MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4-L MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4-P MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4-R MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4W-K MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4W-K/Q MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4W-L MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格
FRTD-S-Z4W-P MSYSTEM Space-saving Plug-in Signal Conditioners F-UNIT 获取价格

FRTD-S-Z3-P 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8