8: S (Usable range -50 to +1760°C, -58 to +3200°F)
Space-saving Plug-in Signal Conditioners F-UNIT
N: N (Usable range -270 to +1300°C, -454 to +2372°F)
0: Specify
THERMOCOUPLE TRANSMITTER
Functions & Features
[2] OUTPUT
Current
• Accepting direct input from a thermocouple and providing
a standard process signal
A: 4 – 20 mA DC (Load resistance 750 Ω max.)
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)
D: 0 – 20 mA DC (Load resistance 750 Ω max.)
E: 0 – 16 mA DC (Load resistance 900 Ω max.)
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
• 5-segment linearization
• Burnout protection
• High-accuracy cold junction compensation
• Fast response type available
• High-density mounting
Typical Applications
• High-accuracy cold junction compensation benefits narrow
span measurements
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 1000 Ω min.)
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
• 0.1 μA burnout sensing enables long distance
transmission with minimum offset drifts
• Electric furnace (isolation)
• No burnout type can connect to a single T/C in parallel
with a recorder
26 (1.02)
[3] POWER INPUT
AC Power
100
(3.94)
K: 85 – 132 V AC
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
L: 170 – 264 V AC
137
(5.39)
(Operational voltage range 170 – 264 V, 47 – 66 Hz)
DC Power
mm (inch)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
MODEL: FTS–[1][2]-[3][4]
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
ORDERING INFORMATION
• Code number: FTS-[1][2]-[3][4]
Specify a code from below for each of [1] through [4].
(e.g. FTS-2A-L/K/BL/Q)
[4] OPTIONS (multiple selections)
Response Time (0 – 90 %)
blank: Standard (≤ 0.5 sec.)
/K: Fast Response (Approx. 25 msec.)
Burnout
• Temperature range (e.g. 0 – 800°C)
• Special output range (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
blank: Upscale burnout
/BL: Downscale burnout
/BN: No burnout
[1] INPUT THERMOCOUPLE
Other Options
1: (PR) (Usable Range 0 to 1760°C, 32 to 3200°F)
2: K (CA) (Usable range -270 to +1370°C, -454 to +2498°F)
3: E (CRC) (Usable range -270 to +1000°C, -454 to +1832°F)
4: J (IC) (Usable range -210 to +1200°C, -346 to +2192°F)
5: T (CC) (Usable range -270 to +400°C, -454 to +752°F)
6: B (RH) (Usable range 0 to 1820°C, 32 to 3308°F)
7: R (Usable range -50 to +1760°C, -58 to +3200°F)
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
FTS SPECIFICATIONS
ES-1412 Rev.9 Page 1/3
http://www.m-system.co.jp/
MODEL: FTS
/C02: Polyurethane coating
/C03: Rubber coating
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
TERMINAL SCREW MATERIAL
/S01: Stainless steel
Minimum span: 1 mA
Offset: Max. 1.5 times span
Load resistance: Output drive 15 V max.
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
GENERAL SPECIFICATIONS
Construction: Plug-in
Offset: Max. 1.5 times span
Connection: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
Linearization: Standard
INSTALLATION
Power input
•AC: Approx. 4.5 VA
•DC: 24 V approx. 70 mA
110 V approx. 20 mA
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail; Standard Rack Mounting
Frame BX-16H available
Cold junction compensation: CJC sensor attached to the
input terminals
Weight: 200 g (0.44 lb)
INPUT SPECIFICATIONS
Minimum span: 3 mV
Offset: Max. 1.5 times span
Input resistance: 30 kΩ min.
Burnout sensing: 0.1 μA
PERFORMANCE in percentage of span
Accuracy: ±0.4 % (at over 400°C or 750°F for R, S and PR;
over 770°C or 1420°F for B)
Cold junction compensation error
Minimum span (in °C)
(PR): min. span 370°C
K (CA): min. span 75°C
E (CRC): min. span 50°C
J (IC): min. span 60°C
T (CC): min. span 75°C
B (RH): min. span 780°C
R: min. span 360°C
(at 20°C ±10°C or 68°F ±18°F)
K, E, J, T, N: ±0.5°C or ±0.9°F
S, R, PR: ±1°C or ±1.8°F
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
(at over 400°C or 750°F for R, S and PR; over 770°C or
1420°F for B)
Burnout response: ≤ 10 sec.
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength
S: min. span 380°C
N: min. span 110°C
Power input code R:
Minimum span (in °F)
(PR): min. span 670°F
K (CA): min. span 140°F
E (CRC): min. span 90°F
J (IC): min. span 110°F
T (CC): min. span 140°F
B (RH): min. span 1410°F
R: min. span 650°F
1000 V AC @ 1 minute (input to output)
2000 V AC @ 1 minute (input or output or power to ground)
500 V AC @ 1 minute (I/O to power)
Power input code K, L, P:
1000 V AC @ 1 minute (input to output)
2000 V AC @ 1 minute (input or output or power to ground)
1500 V AC @ 1 minute (I/O to power)
S: min. span 690°F
N: min. span 200°F
Note: The described accuracy may be partially not satisfied
when the temperature ranges below 0°C. Consult factory.
FTS SPECIFICATIONS
ES-1412 Rev.9 Page 2/3
http://www.m-system.co.jp/
MODEL: FTS
EXTERNAL DIMENSIONS unit: mm (inch)
CLAMP
(top & bottom)
7.8 (.31)
1
2
15
(.59)
DIN RAIL
35mm wide
3
4
2–4.5 (.18)
HOLE
15 (.59) deep
5
6
8–M3.5
SCREW
7
8
26 (1.02)
107 (4.21)
137 (5.39)
26 (1.02)
[3.3 (.13)]
•When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm (inch)
CJC SENSOR
(model: CJM)
red
black
1
2
3
4
5
6
7
8
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
comp. leadwire
Isolation
T / C
Z
S
+
Low Drift
Amplifier
Output
Driver
+
1
5
6
7
8
+
Linearizer
OUTPUT
–
metal leg
–
–
2
3
4
U(+)
V(–)
CJC
SENSOR
POWER
*
red
CJC Sensing
Volt. Generator
model: CJM
black
Base Socket
*Deleted with B thermocouple
Specifications are subject to change without notice.
FTS SPECIFICATIONS
ES-1412 Rev.9 Page 3/3
http://www.m-system.co.jp/
FTS-N5-L/K 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
FTS-N5-L/Q | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-P | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-P/BL | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-P/BN | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-P/K | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-P/Q | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-R | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-R/BL | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-R/BN | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 | |
FTS-N5-R/K | MSYSTEM | Space-saving Plug-in Signal Conditioners F-UNIT | 获取价格 |
FTS-N5-L/K 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8