HPR-14-R [MSYSTEM]

Space-saving Plug-in Signal Conditioners H-UNIT;
HPR-14-R
型号: HPR-14-R
厂家: M-SYSTEM    M-SYSTEM
描述:

Space-saving Plug-in Signal Conditioners H-UNIT

文件: 总4页 (文件大小:127K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: HPR  
Space-saving Plug-in Signal Conditioners H-UNIT  
[3] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
PULSE SCALER  
Functions & Features  
• Converting pulse rate into convenient engineering unit for  
display on a totalizing counter or meter  
• High-density mounting  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
Typical Applications  
/C03: Rubber coating  
• Positive displacement flowmeters and turbine flowmeters  
• Magnetic tachometers  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
CAUTION  
26 (1.02)  
1) This unit's output waveform is not uniform due to its  
scaling method. The user must be aware that it may be  
inconvenient for certain types of application.  
2) This unit is designed to accept at the maximum of 100  
kHz, which may cause errors due to chattering in the input  
pulses.  
93  
(3.66)  
137  
(5.39)  
Use input relays which do not cause chattering (e.g.  
mercury relays). Other relays could be used only with a CR  
filter, for 10 Hz at maximum.  
mm (inch)  
3) Use M-System’s Model M2PRU instead of this unit in  
conjunction with the pulse output from M-System’s power  
transducers.  
MODEL: HPR–[1][2]–R[3]  
ORDERING INFORMATION  
• Code number: HPR–[1][2]–R[3]  
R
C = 1 µF  
R = 10kΩ  
PULSE  
SCALER  
Specify a code from below for each of [1] through [3].  
(e.g. HPR-11-R/Q)  
Relay  
C
• Input frequency range (e.g. 0 – 356.7 Hz)  
• Output frequency range (e.g. 0 – 1.00 Hz)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
[1] INPUT  
1: Dry contact (max. 100 kHz)  
2: Voltage pulse (max. 100 kHz)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Input pulse sensing: Capacitor coupled; detecting pulse rise  
Sensitivity adjustment: Single-turn screwdriver adjustment  
(front); 25 mVp-p – 5 Vp-p  
[2] OUTPUT  
1: Open collector (max. frequency 20 kHz)  
2: 5 V pulse (max. frequency 20 kHz)  
3: Relay contact (max. frequency 2 Hz)  
4: 24 V pulse (max. frequency 20 Hz)  
Scaling factor: 0.9999 × 10 – 0.0001 × 10–6  
0
INPUT SPECIFICATIONS  
Dry Contact: Mechanical contact or open collector  
POWER INPUT  
DC Power  
Max. frequency: 100 kHz  
Pulse width time requirement: 5 μsec. min. (20 msec. min.  
for frequencies ≤ 10 Hz)  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Sensing: Approx. 7.5 V DC @ 1 mA  
ON/OFF level: ≤ 20 kΩ for ON, ≥ 100 kΩ for OFF  
HPR SPECIFICATIONS  
ES-3460 Rev.9 Page 1/4  
http://www.m-system.co.jp/  
MODEL: HPR  
Voltage Pulse: Square or sine waveforms*  
Max. frequency: 100 kHz  
Pulse width time requirement: 5 μsec. min. (20 msec. min.  
for frequencies ≤ 10 Hz)  
Input amplitude: 25 mVp-p – 50 Vp-p  
Minimum amplitude requirement  
With duty ratio 50 ±10 %  
(frequency: amplitude)  
24 V Pulse  
Frequency range: 0 – 20 Hz  
High pulse width: Approx. 30 msec.  
High level: 24 V ±10 %  
Low level: ≤ 0.5 V  
Load resistance: 800 Ω minimum  
INSTALLATION  
0 – 2 kHz: 25 mVp-p  
Current consumption: Approx. 80 mA  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail; Standard Rack Mounting  
Frame BX-16H available  
0 – 20 kHz: 50 mVp-p  
0 – 40 kHz: 1 Vp-p  
0 – 100 kHz: 5 Vp-p  
With duty ratio other than 50 ±10 %  
(pulse width: amplitude)  
5 μsec.: 5 Vp-p  
Weight: 200 g (0.44 lb)  
10 μsec.: 3.5 Vp-p  
PERFORMANCE  
50 μsec.: 2 Vp-p  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 500 V AC @ 1 minute  
(input to output to power)  
100 μsec.: 1 Vp-p  
500 μsec.: 0.5 Vp-p  
Input impedance: 100 kΩ minimum  
1500 V AC @ 1 minute (input or output or power to ground)  
*Voltage pulse examples  
25mV – 50V  
0V  
25mV – 50V  
0V  
25mV p-p  
– 50V p-p  
0V  
OUTPUT SPECIFICATIONS  
■ Open Collector: 50 V DC @ 50 mA (resistive load)  
Frequency range: 0 – 20 kHz  
ON pulse width: Approx. 30 μsec.  
Saturation voltage: 0.6 V DC  
Relay Contact: 120 V AC @ 200 mA (cos ø = 1)  
240 V AC @ 100 mA (cos ø = 1)  
24 V DC @ 200 mA (resistive load)  
Maximum switching voltage: 240 V AC or 30 V DC  
Maximum switching power: 24 VA or 4.8 W  
Minimum load: 5 V DC @ 10 mA  
Frequency range: 0 – 2 Hz  
ON pulse width: Approx. 30 msec.  
Relay life: ≥ 5 × 10  
≥ 10 cycles (electrical)  
5 V Pulse  
7
cycles (mechanical)  
5
Frequency range: 0 – 20 kHz  
Low pulse width: Approx. 30 μsec.  
High level: 5 V ±10 %  
Low level: ≤ 0.5 V  
Load resistance: 600 Ω minimum  
HPR SPECIFICATIONS  
ES-3460 Rev.9 Page 2/4  
http://www.m-system.co.jp/  
MODEL: HPR  
EXTERNAL VIEW  
Sensitivity Adj.  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
7.8 (.31)  
CLAMP  
(top & bottom)  
1
2
15  
(.59)  
DIN RAIL  
35mm wide  
3
4
2–4.5 (.18)  
HOLE  
15 (.59) deep  
5
6
8–M3.5  
SCREW  
7
8
107 (4.21)  
137 (5.39)  
26 (1.02)  
26 (1.02)  
[3.3 (.13)]  
•When mounting, no extra space is needed between units.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
SENSITIVITY  
ADJ.  
Isolation  
Pulse Volt.  
Amplifier  
Output  
Driver  
+
1
2
3
4
5
6
7
8
+
+
Scaler  
One-shot  
INPUT  
OUTPUT  
POWER  
Base Socket  
Input Connection Examples  
Output Connection Examples  
Dry Contact  
Open Collector  
Relay Contact  
•AC Powered  
+7.5V  
4kΩ  
Relay or  
Counter Coil  
+
+
1
2
+
+
5
6
5
Varistor or Spark  
Quenching CIrcuit  
LOAD  
6
U
Voltage Pulse  
Voltage Pulse  
•DC Powered  
Relay or  
Counter Coil  
+
+
1
2
+
+
5
6
5
6
Spark Quenching  
Diode  
LOAD  
HPR SPECIFICATIONS  
ES-3460 Rev.9 Page 3/4  
http://www.m-system.co.jp/  
MODEL: HPR  
Specifications are subject to change without notice.  
HPR SPECIFICATIONS  
ES-3460 Rev.9 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

HPR-14-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-21-R

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-21-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-22-R

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-22-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-23-R

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-23-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-24-R

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-24-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HPR-60AA

Single Phase High Power type DC to DC Solid State Module
FOTEK

HPR-60AA-H

Single Phase High Power type DC to DC Solid State Module
FOTEK

HPR-60DA

Single Phase High Power type DC to DC Solid State Module
FOTEK