JRQ2-14W-R/Q [MSYSTEM]

Plug-in Signal Conditioners M-UNIT;
JRQ2-14W-R/Q
型号: JRQ2-14W-R/Q
厂家: M-SYSTEM    M-SYSTEM
描述:

Plug-in Signal Conditioners M-UNIT

文件: 总5页 (文件大小:156K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: JRQ2  
Plug-in Signal Conditioners M-UNIT  
INPUT – Field-selectable  
Open collector  
Voltage pulse  
ENCODER POSITION TRANSMITTER  
(field-programmable; built-in excitation)  
Functions & Features  
RS-422 line driver pulse  
Two inputs (phase A and B) are required for adequate  
operation of the this unit.  
• Converts a two-phase forward and reverse rotation pulse  
signal with 90 degree phase difference into a forward and  
reverse position signal  
[1] EXCITATION  
1: 5 V DC @ 120 mA  
4: 12 V DC @ 60 mA  
7: 24 V DC @ 25 mA  
• Built-in excitation  
• Field-selectable input type and range  
• Isolation up to 2000 V AC  
• High-density mounting  
[2] OUTPUT  
Current  
Typical Applications  
• Measuring moving distance of a machine with a rotary  
encoder  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
72  
(2.83)  
80  
(3.15)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)  
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
136  
(5.35)  
mm (inch)  
MODEL: JRQ2–[1][2]–[3][4]  
ORDERING INFORMATION  
• Code number: JRQ2-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. JRQ2-76-K/Q)  
[3] POWER INPUT  
AC Power  
• Special output range (For codes Z & 0)  
• Use Ordering Information Sheet (No. ESU-1576). Factory  
setting (table below) will be used if not otherwise specified.  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
K: 85 – 132 V AC  
DC Power  
S: 12 V DC  
R: 24 V DC  
Factory Setting  
V: 48 V DC  
Input type  
Pulse amplitude  
Noise filter  
Open collector  
----  
None  
P: 110 V DC  
Detecting level  
1V * (5V excitation)  
2V * (12/24V excitation)  
[4] OPTIONS  
blank: none  
Count mode  
1 count / 1 pulse  
(Phase B by one pulse edge)  
Input zero count  
Input span count  
0
1000  
/Q: With options (specify the specification)  
Alarm setpoint  
Alarm deadband  
Alarm mode  
100%  
1.00%  
High alarm  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Linearization  
Without  
Input count at power off  
Not held (Cold Start)  
* Detecting voltage in the internal circuit  
/C02: Polyurethane coating  
JRQ2 SPECIFICATIONS  
ES-1576 Rev.8 Page 1/5  
http://www.m-system.co.jp/  
MODEL: JRQ2  
/C03: Rubber coating  
Positive side: Held at the max. of 115 %  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
Negative side: Held at the min. of -15 %  
INPUT SPECIFICATIONS  
Excitation: Shortcircuit protection; approx. 440 mA (max.) at  
shortcircuit  
RELATED PRODUCTS  
• Programming Unit (model: PU-2x)  
• PC configurator software (model: JXCON)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual for the PC configurator for applicable  
cable types.  
Maximum frequency: 200 kHz  
Maximum count range: -99999999 to +99999999  
Minimum pulse width time requirement: 2.5 μsec. for both  
ON and OFF  
Open Collector  
Input requirements (Excitation: Sensing)  
5 V: Approx. 4 V / 1.0 mA  
12 V: Approx. 9 V / 2.3 mA  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
24 V: Approx. 16 V / 4.7 mA  
ON resistance: ≤ 200 Ω  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
OFF resistance: ≥ 200 kΩ  
Detecting level:  
1 V (5 V excitation)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to DC output to alarm output to power  
Overrange output: Approx. -15 to +115 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Alarm mode: High or Low  
2 V (12/24 V excitation)  
(Detecting voltage in the internal circuit. For open collector  
input, be sure to re-adjust the voltage back to 1 V (5 V  
excitation) or 2 V (12/24 V excitation) if it has been changed  
for other input types.)  
Detecting pulse edge: OFF (input monitor LED ON) to ON  
(LED OFF)  
Alarm setpoint: -15 – +115 %  
Alarm deadband: 0 – 20 %  
Voltage Pulse  
Input monitor (PL1): Red LED blinks according to the input  
phase A.  
Waveform: Square or sine  
Input impedance: 10 kΩ min.  
Input monitor (PL2): Red LED blinks according to the input  
phase B.  
Pulse amplitude: 0.1 – 100 Vp-p  
Max. voltage between input terminals: 50 V  
Detecting level: 0 – 5 V  
Excitation adjustment: 5 – 24 V DC  
Software programming: Programming Unit (model: PU-2x);  
(Refer to the users manual of JXCON for the adjustments  
configurable with JXCON)  
(Detecting voltage in the internal circuit.)  
Detecting pulse state: A pulse rise detected when the input  
voltage goes above the detecting level (input monitor LED  
ON); a pulse sink detected when it goes below  
the level (LED OFF).  
• Input count range  
• Zero and span adjustment  
• Linearization  
RS-422 Line Driver Pulse  
• Alarm setpoint  
Receiver: Conforms to RS-422  
• Output fine adjustment  
• Others  
Reset Input  
Adjustments: With DIP and Rotary switches.  
• Input Type  
Sensing voltage: 4.5 V DC  
Detecting level  
ON: ≤ 1 V  
• Noise Filter  
• Pulse amplitude  
OFF: ≥ 4 V  
Voltage pulse waveform  
(Refer to the instruction manual for details)  
Modular jack: Connecting the PU-2x  
Input pulse sensing: DC coupled  
Reset input: Resets the internal counter value (The  
transmitter output equivalent to 0 count when the reset  
input terminals are closed for 500 msec. or longer.)  
Ouput at input/zero/span count overflow  
Volts  
50V max.  
Amplitude  
Vinp-p  
DC Offset  
t
JRQ2 SPECIFICATIONS  
ES-1576 Rev.8 Page 2/5  
http://www.m-system.co.jp/  
MODEL: JRQ2  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 10 mA max.; 5 mA for  
negative voltage output; at ≥ 0.5 V  
Alarm Output: Relay contact  
Rated load: 125 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 0.5 A (resistive load)  
Maximum switching voltage: 250 V AC or 125 V DC  
Maximum switching power: 62.5 VA or 60 W  
Minimum load: 10 mV DC @ 1 mA  
Mechanical life: 5 × 10 cycles (300 cycles/minute)  
7
For maximum relay life with inductive loads, external  
protection is recommended.  
INSTALLATION  
Power input  
AC: Operational voltage range 85 – 132 V,  
47 – 66 Hz, approx. 7 VA  
DC: Operational voltage range: Rating ±10 %, or 85 – 150  
V for 110 V rating; ripple 10 %p-p max.; Approx. 4 W (140  
mA at 24 V)  
Operating temperature: -5 to +60°C (23 to 140°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 350 g (0.77 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 %  
Alarm setpoint accuracy: ±0.1 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength:  
2000 V AC @ 1 minute (input to output to power)  
1500 V AC @ 1 minute (input or output or power to alarm  
output)  
2000 V AC @ 1 minute (circuit to ground)  
JRQ2 SPECIFICATIONS  
ES-1576 Rev.8 Page 3/5  
http://www.m-system.co.jp/  
MODEL: JRQ2  
EXTERNAL VIEW  
Input Type Selectors  
ON  
Modular Jack  
1
2
3
4
5
6
7
8
Input Monitor LED PL1  
Input Monitor LED PL2  
1
Detecting Level Adj.  
SW3  
1
2
3
4
5
6
7
8
Detecting Level Adj. Pin  
Pulse Amplitude Selector  
Sensor Excitation Adj.  
SW1  
1
2
3
4
5
6
7
8
SW2  
Zero Adj.  
Span Adj.  
Refer to the instruction manual for detailed procedures.  
OPERATION  
FORWARD  
FORWARD  
STOP  
REVERSE  
STOP  
20mA  
+10V  
Ǿ
Ǿ
A
B
INPUT  
INPUT  
REVERSE  
+
4mA  
rev. 30 counts  
–10V  
rev. 100 counts  
OUTPUT  
RESET  
0
fwd. 100 counts  
fwd. 100 counts  
OPEN CLOSE  
Pulse counts are added or subtracted according to the rotary encoder’s rotating directions.  
The counts are added when Phase A leads Phase B by 90 degrees (Forward rotation), and  
subtracted when Phase A lags behind Phase B by 90 degrees (Reverse rotation).  
min. 500 msec.  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
7
14  
6
5
12  
4
3
2–4.5 (.18) dia.  
MTG HOLE  
25 (.98) deep  
8
9
15 10  
1
11  
2
14–M3.5  
SCREW  
50 (1.97)  
72 (2.83)  
107 (4.21)  
136 (5.35)  
60 (2.36)  
72 (2.83)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
JRQ2 SPECIFICATIONS  
ES-1576 Rev.8 Page 4/5  
http://www.m-system.co.jp/  
MODEL: JRQ2  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
OPEN COLLECTOR or VOLTAGE PULSE INPUT  
10  
Ry  
ALARM OUTPUT  
2
9
Reset  
Input  
+
RESET INPUT  
12  
6
*
15  
DETECT. LEVEL  
INPUT  
MON.  
INPUT TYPE  
Z
S
Isolation  
Waveform  
Shaper  
Digital  
Computation  
Output  
Driver  
A
+
+
φ
4
3
1
OUTPUT  
POWER  
COM  
ROTARY  
ENCODER  
11  
7
INPUT  
MON.  
U(+)  
V(–)  
Waveform  
Shaper  
B
+
+
φ
5
8
14  
VS  
Exc.  
Supply  
PWR  
PU-2x  
MODULAR JACK  
SERIAL TRANSMISSION LINE  
Base Socket  
RS-422 LINE DRIVER INPUT  
10  
Ry  
ALARM OUTPUT  
2
9
Reset  
Input  
+
RESET INPUT  
*
15  
3
+
+
+
COM  
INPUT TYPE  
INPUT  
MON.  
Z
S
Isolation  
φ
φ
φ
φ
A
A
B
B
4
RS-422  
Receiver  
Digital  
Computation  
Output  
Driver  
+
1
11  
7
12  
5
OUTPUT  
POWER  
INPUT  
MON.  
RS-422  
Receiver  
U(+)  
V(–)  
6
VS  
14  
Excitation  
Supply  
PWR  
ROTARY  
ENCODER  
8
PU-2x  
MODULAR JACK  
SERIAL TRANSMISSION LINE  
Base Socket  
*
Terminals 3 and 15 are internally connected.  
COM terminals of the rotary encoder and the reset input can be connected to either one.  
Specifications are subject to change without notice.  
JRQ2 SPECIFICATIONS  
ES-1576 Rev.8 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY