KAPU-B6C/Q

更新时间:2024-10-29 22:40:26
品牌:MSYSTEM
描述:Plug-in Signal Conditioners K-UNIT

KAPU-B6C/Q 概述

Plug-in Signal Conditioners K-UNIT

KAPU-B6C/Q 数据手册

通过下载KAPU-B6C/Q数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: KAPU  
15: 0 – 50 mV DC (Input resistance 10 kΩ min.)  
Plug-in Signal Conditioners K-UNIT  
16: 0 – 60 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
DC/FREQUENCY CONVERTER  
(field-configurable)  
Functions & Features  
• Providing a pulse rate output in proportion to DC input  
signal  
• Frequency range adjustable with a front-mounted 16-  
position rotary switch and potentiometer  
• Low-end cutout adjustable  
[2] OUTPUT  
• Isolation up to 2000 V AC  
1: Open collector (max. frequency 10 kHz)  
• High-density mounting  
2: 5 V pulse (max. frequency 10 kHz)  
3: Relay contact (max. 130 pulses/min.)  
4: Low frequency open collector (max. 130 pulses/min.)  
5: Low frequency 5 V pulse (max. 130 pulses/min.)  
6: 24 V pulse (max. 130 pulses/min.)  
Typical Applications  
• Totalizing applications in combination with a counter  
50  
(1.97)  
7: Middle range frequency open collector (max. 312 Hz)  
8: Middle range frequency 5 V voltage pulse (max. 312 Hz)  
K•UNIT  
80  
(3.15)  
SPAN  
Model  
KAPU  
ZERO  
[3] POWER INPUT  
AC Power  
CUTOUT  
CUTOUT  
ADJ.  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
123  
OUTPUT  
RANGE  
PULSE  
WIDTH ADJ  
(4.84)  
mm (inch)  
MODEL: KAPU-[1][2]-[3][4]  
ORDERING INFORMATION  
• Code number: KAPU-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. KAPU-61-B/Q)  
DC Power  
S: 12 V DC  
R: 24 V DC  
• Special input range (For codes Z & 0)  
• Output frequency range (e.g. 0 – 500 Hz)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
[1] INPUT  
Current  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
A1: 4 – 20 mA DC (Input resistance 50 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
E: 0 – 16 mA DC (Input resistance 62.5 Ω)  
F: 0 – 10 mA DC (Input resistance 100 Ω)  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
Z: Specify current (See INPUT SPECIFICATIONS)  
Voltage  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
KAPU SPECIFICATIONS  
ES-3582 Rev.13 Page 1/5  
http://www.m-system.co.jp/  
MODEL: KAPU  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Minimum load: 5 V DC @ 10 mA  
Frequency range: 0 – 130 pulses/min.  
ON pulse width: 40 msec. – 0.8 sec. adjustable  
Relay life:  
Zero adjustment: 0 – 5 % (front)  
Span adjustment: 50 – 100 % of range (front)  
Output frequency adjustment: Preselecting range  
with a rotary switch and fine control  
≥ 5 × 10  
7
cycles (mechanical)  
≥ 10 cycles (electrical)  
5
with span adjustment (50 – 100 %)  
5 V Pulse  
Output pulse width adjustment:Three-turn screwdriver  
adjustment (front)  
Frequency range: 0 – 10 kHz  
Low pulse width: 40 μsec. – 0.8 msec. adjustable  
High level: 5 V ± 10 %  
Low-end cutout: 0 to 10 % (front); a red LED assists in  
adjusting the cutout point; turns on during the cutout.  
Low level: ≤ 0.5 V  
Load resistance: 600 Ω min.  
Middle Range Frequency 5 V Pulse  
Frequency range: 0 – 312 Hz  
Low pulse width: 2 – 35 msec. adjustable  
High level: 5 V ±10 %  
INPUT SPECIFICATIONS  
DC Current:  
Shunt resistor attached to the input terminals (0.5 W)  
Specify input resistance value for code Z.  
DC Voltage: -300 – +300 V DC  
Minimum span: 10 mV  
Low level: ≤0.5 V  
Load resistance: 600 Ω min.  
Low Frequency 5 V Pulse  
Frequency range: 0 – 130 pulses/min.  
Low pulse width: 40 msec. – 0.8 sec. adjustable  
High level: 5 V ± 10 %  
Offset: Max. 1.5 times span  
Input resistance  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Low level: ≤ 0.5 V  
Span ≥ 1 V : ≥ 1 MΩ  
Load resistance: 600 Ω min.  
24 V Pulse  
OUTPUT SPECIFICATIONS  
Note: For factory setting, maximum frequency of the  
selected range is used to determine pulse width. Pulse  
width is adjusted until the duty ratio becomes 50 % of the  
maximum frequency. If this value lies outside of the  
adjustable range, either maximum or minimum selectable  
value will be used.  
Frequency range: 0 – 130 pulses/min.  
High pulse width: 40 msec. – 0.8 sec. adjustable  
High level: 24 V ±10%  
Low level: ≤ 0.5 V  
Load current: 30 mA max.  
Load resistance: 800 Ω min.  
Open Collector, 5V Pulse  
Open Collector:  
SPAN RANGE  
SW No.  
50 V DC @ 50 mA (resistive load)  
MIN. (50%)  
MAX. (100%)  
Frequency range: 0 – 10 kHz  
0 – 10 kHz  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 – 5 kHz  
ON pulse width: 40 μsec. – 0.8 msec. adjustable  
Saturation voltage: 0.6 V DC  
0 – 5 kHz  
0 – 2.5 kHz  
0 – 1.25 kHz  
0 – 625 Hz  
0 – 312 Hz  
0 – 156 Hz  
0 – 78 Hz  
0 – 39 Hz  
0 – 20 Hz  
0 – 10 Hz  
0 – 5 Hz  
0 – 2.5 kHz  
0 – 1.25 kHz  
0 – 625 Hz  
0 – 312 Hz  
0 – 156 Hz  
0 – 78 Hz  
0 – 39 Hz  
0 – 20 Hz  
0 – 10 Hz  
0 – 5 Hz  
Low Frequency Open Collector:  
50 V DC @ 50 mA (resistive load)  
Frequency range: 0 – 130 pulses/min.  
ON pulse width: 40 msec. – 0.8 sec. adjustable  
Saturation voltage: 0.6 V DC  
Middle Range Frequency Open Collector:  
50 V DC @ 50 mA (resistive load)  
0 – 2.5 Hz  
Frequency range: 0 – 312 Hz  
0 – 2.5 Hz  
0 – 1.25 Hz  
ON pulse width: 2 – 35 msec. adjustable  
Saturation voltage: 0.6 V DC  
0 – 1.25 Hz  
0 – 36 pulses/min.  
0 – 18 pulses/min.  
0 – 9 pulses/min.  
0 – 36 pulses/min.  
0 – 18 pulses/min.  
Relay Contact: 120 V AC @ 200 mA (cos ø = 1)  
240 V AC @ 100 mA (cos ø = 1)  
24 V DC @ 200 mA (resistive load)  
Maximum switching voltage: 380 V AC or 125V DC  
Maximum switching power: 24 VA or 4.8 W  
KAPU SPECIFICATIONS  
ES-3582 Rev.13 Page 2/5  
http://www.m-system.co.jp/  
MODEL: KAPU  
Line voltage effect: ±0.1 % over voltage range  
• Middle Range Frequency Open Collector & 5V Pulse  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
SPAN RANGE  
SW No.  
MIN. (50%)  
Not Used  
Not Used  
Not Used  
Not Used  
Not Used  
0 – 156 Hz  
0 – 78 Hz  
0 – 39 Hz  
0 – 20 Hz  
0 – 10 Hz  
0 – 5 Hz  
MAX. (100%)  
Not Used  
Not Used  
Not Used  
Not Used  
Not Used  
0 – 312 Hz  
0 – 156 Hz  
0 – 78 Hz  
0 – 39 Hz  
0 – 20 Hz  
0 – 10 Hz  
0 – 5 Hz  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 – 2.5 Hz  
0 – 2.5 Hz  
0 – 1.25 Hz  
0 – 1.25 Hz  
0 – 36 pulses/min.  
0 – 18 pulses/min.  
0 – 9 pulses/min.  
0 – 36 pulses/min.  
0 – 18 pulses/min.  
• Relay Contact, Low-Freq. Open Collector & 5V Pulse, 24V Pulse  
SPAN RANGE  
SW No.  
MIN. (50%)  
MAX. (100%)  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 – 65 pulses/min.  
0 – 32 pulses/min.  
0 – 16 pulses/min.  
0 – 8 pulses/min.  
0 – 4 pulses/min.  
0 – 2 pulses/min.  
0 – 1 pulses/min.  
0 – 0.5 pulses/min.  
0 – 0.25 pulses/min.  
0 – 8 pulses/hour  
0 – 4 pulses/hour  
0 – 2 pulses/hour  
0 – 130 pulses/min.  
0 – 65 pulses/min.  
0 – 32 pulses/min.  
0 – 16 pulses/min.  
0 – 8 pulses/min.  
0 – 4 pulses/min.  
0 – 2 pulses/min.  
0 – 1 pulses/min.  
0 – 0.5 pulses/min.  
0 – 0.25 pulses/min.  
0 – 8 pulses/hour  
0 – 4 pulses/hour  
0 – 1 pulses/hour  
0 – 2 pulses/hour  
0 – 1 pulses/hour  
0 – 0.5 pulses/hour  
0 – 0.24 pulses/hour  
0 – 0.5 pulses/hour  
0 – 0.24 pulses/hour  
0 – 0.12 pulses/hour  
INSTALLATION  
Power input  
AC: Operational voltage range: rating ±10 %,  
50/60 ±2 Hz, approx. 2 VA  
DC: operational voltage range: rating ±10 %  
(ripple 10 %p-p max.)  
approx. 2 W (70 mA at 24 V)  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 350 g (0.77 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.25 %  
Temp. coefficient: ±0.05 %/°C (±0.03 %/°F)  
KAPU SPECIFICATIONS  
ES-3582 Rev.13 Page 3/5  
http://www.m-system.co.jp/  
MODEL: KAPU  
EXTERNAL VIEW  
Span Adj.  
Zero Adj.  
Low-End Cutout  
Monitor LED  
Low-End Cutout  
Adjustment  
Pulse Width Adj.  
Range Selector  
EXTERNAL DIMENSIONS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
6
5
4
3
2–  
4.5 (.18) dia.  
MTG HOLE  
15 (.59) deep  
7
8
1
2
8–  
M3.5  
SCREW  
50 (1.97)  
103 (4.06)  
123 (4.84)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
TERMINAL ASSIGNMENTS unit: mm (inch)  
INPUT RESISTOR  
(model: REM)  
6
5
4
3
7
8
1
2
Input shunt resistor attached  
for current input.  
KAPU SPECIFICATIONS  
ES-3582 Rev.13 Page 4/5  
http://www.m-system.co.jp/  
MODEL: KAPU  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
ROTARY SWITCH  
Divider  
PULSE WIDTH  
Z
S
Isolation  
Low Drift  
Amplifier  
Volt. / Freq.  
Converter  
Output  
Driver  
+
3
4
5
6
1
2
7
8
+
*
INPUT  
R
OUTPUT  
Low-End  
Cutout  
U(+)  
V(–)  
POWER  
CUTOUT ADJ.  
Base Socket  
Input shunt resistor attached for current input.  
*
Output Connection Examples  
Open Collector  
Relay  
•AC Powered  
Relay or  
Counter Coil  
1
2
+
+
1
2
Varistor or Spark  
Quenching Circuit  
LOAD  
U
Voltage Pulse  
•DC Powered  
Relay or  
Counter Coil  
1
2
+
+
1
2
Spark Quenching Diode  
LOAD  
Specifications are subject to change without notice.  
KAPU SPECIFICATIONS  
ES-3582 Rev.13 Page 5/5  
http://www.m-system.co.jp/  

KAPU-B6C/Q 相关器件

型号 制造商 描述 价格 文档
KAPU-B6D MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6D/Q MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6E MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6E/Q MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6F MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6F/Q MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6G MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6G/Q MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6H MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格
KAPU-B6H/Q MSYSTEM Plug-in Signal Conditioners K-UNIT 获取价格

KAPU-B6C/Q 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8