KSL-Z5-H/Q [MSYSTEM]

Plug-in Signal Conditioners K-UNIT;
KSL-Z5-H/Q
型号: KSL-Z5-H/Q
厂家: M-SYSTEM    M-SYSTEM
描述:

Plug-in Signal Conditioners K-UNIT

文件: 总5页 (文件大小:174K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: KSL  
K: 0 – 100 μA DC (Input resistance 1000 Ω)  
Plug-in Signal Conditioners K-UNIT  
GW: -1 – +1 mA DC (Input resistance 1000 Ω)  
FW: -10 – +10 mA DC (Input resistance 100 Ω)  
Z: Specify current (See INPUT SPECIFICATIONS)  
Voltage  
DC ALARM  
(rotary switch adjustments)  
Functions & Features  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
15: 0 – 50 mV DC (Input resistance 10 kΩ min.)  
16: 0 – 60 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)  
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
• Providing relay contact closures at preset DC input levels  
• Dual (Hi/Lo) trip  
• Rotary switch setpoint adjustments  
• Enclosed relays  
• Relays can be powered 110 V DC  
• Isolation up to 2000 V AC  
• High-density mounting  
Typical Applications  
• Annunciator  
• Various alarm applications  
[2] OUTPUT  
2: Relay; N.O. or make contact  
3: Relay; N.C. or break contact  
5: Relay; SPDT or transfer contact  
50  
(1.97)  
K•UNIT  
80  
(3.15)  
Model  
x10  
KSL  
HI SET.  
(%)  
[3] POWER INPUT  
AC Power  
X1  
x10  
LO SET.  
(%)  
X1  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
123  
(4.84)  
*
*
132 (5.20) for KSL-x5  
mm (inch)  
MODEL: KSL–[1][2]–[3][4]  
ORDERING INFORMATION  
• Code number: KSL-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. KSL-62-B/Q)  
DC Power  
S: 12 V DC  
R: 24 V DC  
• Special input range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
[1] INPUT  
Current  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
A1: 4 – 20 mA DC (Input resistance 50 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
E: 0 – 16 mA DC (Input resistance 62.5 Ω)  
F: 0 – 10 mA DC (Input resistance 100 Ω)  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
J: 0 – 10 μA DC (Input resistance 1000 Ω)  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
KSL SPECIFICATIONS  
ES-3613 Rev.10 Page 1/5  
http://www.m-system.co.jp/  
MODEL: KSL  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Alarm Trip Operation Terminal No. in parentheses  
• Output Code 2  
Connection: M3.5 screw terminals  
(1–2)ON  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Hi Output  
(5–6)ON  
Lo Output  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Input  
(%)  
0
s
Lo Setpoint  
50  
s
Hi Setpoint  
100  
Setpoint adjustments: 10-position rotary switches (front); 0  
– 99 % independently; 1 % increments  
Hysteresis (deadband): 1 – 2.5 %  
• Output Code 3  
(1–2)ON  
Hi Output  
Front LEDs: Red LEDs turn on when the coils are energized.  
Power ON timer: Relays de-energized for approx. 2 seconds  
after power is turned on.  
(5–6)ON  
Lo Output  
Input  
(%)  
0
s
Lo Setpoint  
50  
s
Hi Setpoint  
100  
INPUT SPECIFICATIONS  
DC Current:  
• Output Code 5  
(1–2)ON  
Hi Output  
Shunt resistor attached to the input terminals (0.5 W)  
Specify input resistance value for code Z.  
DC Voltage: -300 – +300 V DC  
Minimum span: 10 mV  
(1–3)ON  
(9–10)ON  
Lo Output  
(9–11)ON  
Input  
(%)  
Offset: Max. 1.5 times span  
Input resistance  
0
s
Lo Setpoint  
50  
s
Hi Setpoint  
100  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Trip Operation in Power Failure  
• Output Code 2: both relays turn OFF  
• Output Code 3: both relays turn ON  
• Output Code 5: Terminals 1 – 3, 9 – 11 turn ON  
Span ≥ 1 V : ≥ 1 MΩ  
OUTPUT SPECIFICATIONS  
Relay Contact: 100 V AC @1 A (cos ø = 1)  
120 V AC @1 A (cos ø = 1)  
INSTALLATION  
Power input  
240 V AC @0.5 A (cos ø = 1)  
AC: Operational voltage range: rating ±10 %,  
50/60 ±2 Hz, approx. 2 VA  
30 V DC @1 A (resistive load)  
Maximum switching voltage: 380 V AC or 125 V DC  
Maximum switching power: 120 VA or 30 W  
Minimum load: 5 V DC @10 mA  
DC: Operational voltage range: rating ±10 %,  
ripple 10 %p-p max., approx. 2 W (80 mA at 24 V)  
Operating temperature: -5 to +55°C (23 to 131°F)  
Mechanical life: 5 × 10 cycles  
7
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
For maximum relay life with inductive loads, external  
protection is recommended.  
Weight: 400 g (0.88 lb)  
PERFORMANCE in percentage of span  
Setpoint accuracy: ±0.5 %  
Trip point repeatability: ±0.05 %  
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)  
Response time: 0.5±0.2 sec. (0 – 100 % at 90 % setpoint)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
KSL SPECIFICATIONS  
ES-3613 Rev.10 Page 2/5  
http://www.m-system.co.jp/  
MODEL: KSL  
EXTERNAL VIEW  
Hi LED  
Hi Setpoint Rotary Switch (×10%)  
Hi Setpoint Rotary Switch (×1%)  
x10  
HI SET  
[%]  
x1  
Lo Setpoint Rotary Switch (×10%)  
Lo Setpoint Rotary Switch (×1%)  
Lo LED  
x10  
LO SET  
[%]  
x1  
EXTERNAL DIMENSIONS unit: mm (inch)  
■OUTPUT CODE: 2, 3  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
6
5
4
3
2–  
4.5 (.18) dia.  
MTG HOLE  
15 (.59) deep  
7
8
1
2
8–  
M3.5  
SCREW  
50 (1.97)  
103 (4.06)  
123 (4.84)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
■OUTPUT CODE: 5  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
8
9
7
6
5
4
2
4.5 (.18) dia.  
MTG HOLE  
25 (.98) deep  
3
2
10 11  
1
11  
M3.5  
SCREW  
50 (1.97)  
103 (4.06)  
132 (5.20)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
KSL SPECIFICATIONS  
ES-3613 Rev.10 Page 3/5  
http://www.m-system.co.jp/  
MODEL: KSL  
TERMINAL ASSIGNMENTS unit: mm (inch)  
■OUTPUT CODE: 2, 3  
INPUT RESISTOR  
(model: REM)  
6
5
4
3
7
8
1
2
Input shunt resistor attached  
for current input.  
■OUTPUT CODE: 5  
INPUT RESISTOR  
(model: REM)  
8
7
6
5
4
9
3
2
10 11  
1
Input shunt resistor attached  
for current input.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
■OUTPUT CODE: 2, 3  
N.O. (make) Relay  
ROTARY  
SWITCH  
D / A  
Converter  
N.C. (break) Relay  
1
2
5
6
7
8
1
HI OUTPUT  
LO OUTPUT  
HI OUTPUT  
Low Drift  
Amplifier  
Ry  
Ry  
+
3
4
Comparator  
Comparator  
*
2
5
6
INPUT  
R
LO OUTPUT  
U(+)  
ROTARY  
SWITCH  
D / A  
Converter  
POWER  
V(–)  
Base Socket  
*Input shunt resistor attached for current input.  
KSL SPECIFICATIONS  
ES-3613 Rev.10 Page 4/5  
http://www.m-system.co.jp/  
MODEL: KSL  
■OUTPUT CODE: 5  
Relay Protection  
•AC Powered  
Inductive  
Load (Coil)  
ROTARY  
SWITCH  
D / A  
Converter  
Varistor or Spark  
Quenching Circuit  
LOAD  
3
2
1
N.C.  
Low Drift  
Amplifier  
Ry  
Ry  
+
5
6
4
Comparator  
Comparator  
*
U
N.O. HI OUTPUT  
COM  
INPUT  
R
•DC Powered  
Inductive  
Load (Coil)  
Diode, Varistor or  
CR Circuit  
11 N.C.  
LOAD  
ROTARY  
SWITCH  
D / A  
Converter  
10 N.O. LO OUTPUT  
9
7
8
COM  
U(+)  
V(–)  
POWER  
Base Socket  
*Input shunt resistor attached for current input.  
Specifications are subject to change without notice.  
KSL SPECIFICATIONS  
ES-3613 Rev.10 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

KSL-Z5-J

Plug-in Signal Conditioners K-UNIT
MSYSTEM

KSL-Z5-J/Q

Plug-in Signal Conditioners K-UNIT
MSYSTEM

KSL-Z5-R

Plug-in Signal Conditioners K-UNIT
MSYSTEM

KSL-Z5-R/Q

Plug-in Signal Conditioners K-UNIT
MSYSTEM

KSL-Z5-S

Plug-in Signal Conditioners K-UNIT
MSYSTEM

KSL-Z5-S/Q

Plug-in Signal Conditioners K-UNIT
MSYSTEM

KSL0150070

Strap Type KSL Series
THINKING

KSL0150070S

Strap Type KSL Series
THINKING

KSL0240100

Strap Type KSL Series
THINKING

KSL0240100S

Strap Type KSL Series
THINKING

KSL0240180

Strap Type KSL Series
THINKING

KSL0240180S

Strap Type KSL Series
THINKING