KWRS2-3DC-B/K 概述
Plug-in Signal Conditioners K-UNIT
KWRS2-3DC-B/K 数据手册
通过下载KWRS2-3DC-B/K数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: KWRS2
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)
5: Pt 50 Ω (JIS'81)
Plug-in Signal Conditioners K-UNIT
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 100°C, 180°F)
6: Ni 508.4 Ω
RTD TRANSMITTER
(CE, two isolated outputs)
(Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F)
0: Specify
Functions & Features
• Accepting direct input from an RTD and providing
two standard process signals
Note: Consult M-System for 2-wire RTD
• Linearization
[2] OUTPUT 1
• Burnout protection
Current
• "Active bridge" circuit containing two constant current
sources allows large leadwire resistances up to 200 Ω
• Fast response type available
• High-density mounting
A: 4 – 20 mA DC (Load resistance 600 Ω max.)
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)
D: 0 – 20 mA DC (Load resistance 600 Ω max.)
E: 0 – 16 mA DC (Load resistance 750 Ω max.)
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
Typical Applications
• Long distance transmission between the RTD and the
transmitter
• Combination with intrinsic safety barriers
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 1000 Ω min.)
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
72
(2.83)
80
(3.15)
K-U
N
IT
132
(5.20)
[3] OUTPUT 2
mm (inch)
Current
A: 4 – 20 mA DC (Load resistance 350 Ω max.)
B: 2 – 10 mA DC (Load resistance 700 Ω max.)
C: 1 – 5 mA DC (Load resistance 1400 Ω max.)
D: 0 – 20 mA DC (Load resistance 350 Ω max.)
E: 0 – 16 mA DC(Load resistance 430 Ω max.)
F: 0 – 10 mA DC (Load resistance 700 Ω max.)
G: 0 – 1 mA DC (Load resistance 7000 Ω max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
MODEL: KWRS2–[1][2][3]–[4][5]
ORDERING INFORMATION
• Code number: KWRS2-[1][2][3]-[4][5]
Specify a code from below for each of [1] through [5].
(e.g. KWRS2-4AA-H/BL/Q)
• Temperature range (e.g. 0 – 500°C)
• Special output ranges (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
Same range availability as Output 1
[4] POWER INPUT
AC Power
Note: When the user requires a current and a voltage
output, specify the current to be the Output 1 which allows
a greater load.
G: 200 V AC
H: 220 V AC
J: 240 V AC
[1] INPUT RTD (2- or 3-wire)
1: JPt 100 (JIS'89)
DC Power
S: 12 V DC
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 50°C, 90°F)
3: Pt 100 (JIS'89)
R: 24 V DC
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)
4: Pt 100 (JIS'97, IEC)
KWRS2 SPECIFICATIONS
ES-3519 Rev.7 Page 1/3
https://www.m-system.co.jp/
MODEL: KWRS2
[5] OPTIONS (multiple selections)
Response Time (0 – 90 %)
blank: Standard (≤ 0.5 sec.)
/K: Fast Response (Approx. 25 msec.)
Burnout
INSTALLATION
Power input
•AC: Operational voltage range: rating ±10 %,
50/60 ±2 Hz, approx. 3 VA
•DC: Operational voltage range: rating ±10 %
ripple 10 %p-p max., approx. 3 W (125 mA at 24 V)
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
blank: Upscale burnout
/BL: Downscale burnout
Other Options
blank: none
/Q: Option other than the above (specify the specification)
Weight: 400 g (0.88 lb)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
PERFORMANCE in percentage of span
Accuracy: ±0.2 %
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
Burnout response: ≤ 10 sec.
/C02: Polyurethane coating
/C03: Rubber coating
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2300 V AC @ 1 minute
(input or output to power to ground)
TERMINAL SCREW MATERIAL
/S01: Stainless steel
1350 V AC @ 1 minute (input to output)
1000 V AC @ 1 minute (output 1 to output 2)
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M3.5 screw terminals
Screw terminal: Chromated steel (standard) or stainless
steel
STANDARDS & APPROVALS
EU conformity:
Housing material: Flame-resistant resin (black)
Isolation: Input to output 1 to output 2 to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
Adjustable individually for each output 1 and output 2.
At burnout: Downscale ≤ -10 %, Upscale ≥ 110 %
Linearization: Standard
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
INPUT SPECIFICATIONS
Maximum leadwire resistance: 200 Ω per wire (3-wire)
Sensing current: 2 mA
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
Minimum span: 1 mA
Offset: Max. 1.5 times span
Load resistance: Output drive 12 V max. for Output 1;
7 V max. for Output 2
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
Offset: Max. 1.5 times span
Load resistance: Output drive 1 mA max. at ≥ 0.5 V
KWRS2 SPECIFICATIONS
ES-3519 Rev.7 Page 2/3
https://www.m-system.co.jp/
MODEL: KWRS2
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
CLAMP
(top & bottom)
7.8 (.31)
DIN RAIL
35mm wide
7
14
6
5
12
4
3
2
–4.5 (.18) dia.
MTG HOLE
25 (.98) deep
8
9
15 10
1
11
2
14
–M3.5
SCREW
50 (1.97)
72 (2.83)
103 (4.06)
132 (5.20)
60 (2.36)
72 (2.83)
[3.3 (.13)]
• When mounting, no extra space is needed between units.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Burnout
RTD
4
A
Z
Z
S
Isolation
Reference
Resistor
+
–
Differential
Amplifier
Output
Driver
12
5
1
+
B
B
OUTPUT 1
2mA
2mA
11 –
S
2
Linearizer
Output
Driver
9
+
3
OUTPUT 2
POWER
15 –
6
7
U(+)
V(–)
8
14
10
Base Socket
Specifications are subject to change without notice.
KWRS2 SPECIFICATIONS
ES-3519 Rev.7 Page 3/3
https://www.m-system.co.jp/
KWRS2-3DC-B/K 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
KWRS2-3DC-B/Q | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-C | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-C/BL | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-C/K | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-C/Q | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-D | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-D/BL | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-D/K | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-D/Q | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 | |
KWRS2-3DC-R | MSYSTEM | Plug-in Signal Conditioners K-UNIT | 获取价格 |
KWRS2-3DC-B/K 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8