LRP-11PJW-C/Q 概述
Power Transducer Series L-UNIT
LRP-11PJW-C/Q 数据手册
通过下载LRP-11PJW-C/Q数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: LRP
3: 220 V / 1 A AC
4: 220 V / 5 A AC
Power Transducer Series L-UNIT
5: 220 V / 380 V / 1 A AC (3-phase / 4-wire)
6: 220 V / 380 V / 5 A AC (3-phase / 4-wire)
7: 110 V / 190 V / 1 A AC (3-phase / 4-wire)
8: 110 V / 190 V / 5 A AC (3-phase / 4-wire)
(220 V in code 5 and 6, and 110 V in code 7 and 8
are phase voltage)
VAR TRANSDUCER
Functions & Features
• Providing a DC output signal in proportion to AC reactive
power
• DC output containing little ripple is ideal for computer
input
• "Time division multiplication" method accepts distorted
waveforms
[3] OUTPUT SIGNAL POLARITY
P: Negative in lag, positive in lead
• Isolation up to 2000 V AC
M: Negative in lead, positive in lag
• High-density mounting
Typical Applications
[4] OUTPUT
Current
• Centralized monitoring and control of power management
system in a manufacturing facility or building
A: 4 – 20 mA DC (Load resistance 600 Ω max.)
FW: -10 – +10 mA DC (Load resistance 1000 Ω max.)
GW: -1 – +1 mA DC (Load resistance 10 kΩ max.)
JW: -5 – +5 mA DC (Load resistance 2000 Ω max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
75
(2.95)
75
(2.95)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
1W: -10 – +10 mV DC (Load resistance 10 kΩ min.)
2W: -100 – +100 mV DC (Load resistance 100 kΩ min.)
3W: -1 – +1 V DC (Load resistance 1000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
112
(4.41)
mm (inch)
MODEL: LRP–[1][2][3][4]–[5][6]
[5] AUXILIARY POWER SUPPLY
AC Power
ORDERING INFORMATION
• Code number: LRP–[1][2][3][4]-[5][6]
Specify a code from below for each [1] through [6].
(e.g. LRP-11PA-C/Q)
B: 100 V AC
C: 110 V AC
D: 115 V AC
F: 120 V AC
• Calibration range (e.g. lag 1000 – lead 1000 var)
Spacify the range with lag and lead. Don't use plus or
minus.
G: 200 V AC
H: 220 V AC
J: 240 V AC
• VT ratio, CT ratio (e.g. VT 3300/110 V, CT 250/5 A)
• Special output range (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
DC Power
R: 24 V DC
V: 48 V DC
P: 110 V DC
[1] CONFIGURATION
1: 3-phase / 3-wire
[6] OPTIONS
blank: none
4: 3-phase / 4-wire
/Q: With options (specify the specification)
[2] INPUT (unbalanced load)
(Voltage must be balanced.)
1: 110 V / 5 A AC
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
2: 110 V / 1 A AC
http://www.m-system.co.jp/
LRP SPECIFICATIONS
ES-1977 Rev.15 Page 1/5
MODEL: LRP
/C02: Polyurethane coating
/C03: Rubber coating
■ INPUT RANGE
•3-phase / 3-wire
TERMINAL SCREW MATERIAL
/S01: Stainless steel
INPUT
BURDEN (VA)
AVAILABLE
RANGE
STD.RANGE
VOLT. CURR.
110V/1A
110V/5A 1000 var
220V/1A 400 var
200 var
100 – 240 var
500 – 1200 var
200 – 480 var
1000 – 2400 var
0.1/ph
0.2
GENERAL SPECIFICATIONS
Construction: Stand-alone; terminal access at the front
Connection: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
/phase
0.5/ph
0.1/ph
0.5/ph
0.4
/phase
220V/5A 2000 var
•3-phase / 4-wire
Housing material: Flame-resistant resin (black)
Isolation: Voltage input to current input to output to
auxiliary power
INPUT
BURDEN (VA)
VOLT. CURR.
0.1
AVAILABLE
RANGE
STD.RANGE
110V
/1A 200 var
√ 3
100 – 240 var
500 – 1200 var
175 – 420 var
875 – 2100 var
200 – 480 var
1000 – 2400 var
350 – 840 var
1750 – 4200 var
Computation: Time division multiplication
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
0.1
/phase
0.5
110V
/5A 1000 var
√ 3
/phase
/phase
0.1
Span adjustment: 95 to 105 % (front)
190V
/1A 350 var
√ 3
0.2
/phase
0.5
190V
/5A 1750 var
√ 3
/phase
INPUT SPECIFICATIONS
Frequency: 50 or 60 Hz
/phase
0.1
220V
/1A 400 var
√ 3
• Voltage Input
0.3
/phase
0.5
Operational range: 0 – 120 % of rating
Overload capacity: 150 % of rating for 10 sec., 120 %
continuous
220V
/5A 2000 var
√ 3
/phase
/phase
0.1
380V
/1A 700 var
√ 3
0.4
/phase
0.5
• Current Input
380V
/5A 3500 var
√ 3
/phase
Operational range: 0 – 120 % of rating
Overload capacity: 1000 % of rating for 3 sec., 200 % for 10
sec., 120% continuous
/phase
■ How To Determine Var Range
Calibration Range [var] = (Measuring Range) ÷
((VT Ratio) × (CT Ratio))
OUTPUT SPECIFICATIONS
■ DC Current: -10 – + 20 mA DC
Span: Min. 1 mA, max. 20 mA
Offset: Max. 1.5 times span
Check that the required calibration range is within the
available range in the table.
Load resistance: Output drive 12 V maximum; 10 V for [±]
output
[example]
3-phase / 3-wire, measuring range 75 kvar,
VT 220 / 110 V, CT 250 / 5 A
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
(75 × 10 [var])÷((220 / 110) × (250 / 5))= 750 [var]
3
Offset: Max. 1.5 times span
Load resistance: Output drive 1 mA max. at ≥ 0.5 V
http://www.m-system.co.jp/
LRP SPECIFICATIONS
ES-1977 Rev.15 Page 2/5
MODEL: LRP
OPERATION DIAGRAM (example)
• Negative in lag, positive in lead
OUT
20mA
OUT
+10V
12
4
0
-10V
1000
(Lag)
0
1000var
(Lead)
1000
(Lag)
0
1000var
(Lead)
• Negative in lead, positive in lag
OUT
20mA
OUT
+10V
12
4
0
-10V
1000
(Lag)
0
1000var
(Lead)
1000
(Lag)
0
1000var
(Lead)
INSTALLATION
Auxiliary power supply
•AC: Operational voltage range: rating -15/+10 %,
50/60 Hz, approx. 2 VA
•DC: Operational voltage range: rating ±10 %,
or 85 – 150 V for 110 V rating, ripple 10 %p-p max.,
approx. 2 W (18 mA at 110 V)
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 85 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 450 g (0.99 lb)
PERFORMANCE in percentage of span
Accuracy: ±0.5 % (at 23°C ±10°C or 73.4°F ±18°F,
45 – 65 Hz)
Response time: ≤ 2 sec. (0 – 100 % ±1 %)
Ripple: 0.5 %p-p max.(The output ripple may increase when
there is great difference between the frequencies of input
signal and power supply)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(voltage input to current input to output to auxiliary power
to ground)
Impulse withstand voltage: 1.2 / 50 μsec., ±5 kV
(input to output or ground)
http://www.m-system.co.jp/
LRP SPECIFICATIONS
ES-1977 Rev.15 Page 3/5
MODEL: LRP
CONNECTION DIAGRAM
■ 3-PHASE/3-WIRE
■ 3-PHASE/4-WIRE
SOURCE
1
SOURCE
1
2
3
N
2
3
VT
VT
FUSE
FUSE
U
u
P1
P2
P3
U
V
u
v
P1
P2
P3
P0
14
15
16
11
12
9
14
15
16
13
11
12
9
+
+
OUTPUT
OUTPUT
V
V
v
v
–
–
U
V
u
v
U(+)
U(+)
U
V
u
v
U
u
*
*
AUXILIARY POWER
AUXILIARY POWER
K
K
10
10
V(–)
V(–)
K
K
K
k
1S
1L
3S
3L
1
2
5
6
k
k
k
k
1S
1L
2S
2L
3S
3L
1
2
3
4
5
6
CT
CT
l
l
L
L
l
l
l
L
L
L
LOAD
LOAD
*
The transducer can be powered from the input voltage when the voltage is sufficiently stable and meets other supply voltage requirements.
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
8 (.31)
M3.5 SCREW
(Only on the used terminals)
2–5.8 (.23) dia. or
2–4.8 (.18) dia.
MTG HOLE
8 (.31) deep
DIN RAIL
35mm wide
1
9
2
3
4
5
6
7 8
TERMINAL
COVER
10 11 12 13 14 15 16
112 (4.41)
[3.3 (.13)]
75 (2.95)
•When mounting, no extra space is needed between units.
MOUNTING REQUIREMENTS unit: mm (inch)
■ M5 SCREWS
■ M4 SCREWS
60 (2.36)
60 (2.36)
2–M5
2–M4
http://www.m-system.co.jp/
LRP SPECIFICATIONS
ES-1977 Rev.15 Page 4/5
MODEL: LRP
Specifications are subject to change without notice.
http://www.m-system.co.jp/
LRP SPECIFICATIONS
ES-1977 Rev.15 Page 5/5
LRP-11PJW-C/Q 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
LRP-11PJW-D | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PJW-D/Q | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PJW-P | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PJW-P/Q | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PJW-R | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PJW-R/Q | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PJW-V | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PJW-V/Q | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PZ-B | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 | |
LRP-11PZ-B/Q | MSYSTEM | Power Transducer Series L-UNIT | 获取价格 |
LRP-11PJW-C/Q 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8