LSMT2-31160-V

更新时间:2024-10-29 22:34:26
品牌:MSYSTEM
描述:MULTI POWER TRANSDUCER

LSMT2-31160-V 概述

MULTI POWER TRANSDUCER

LSMT2-31160-V 数据手册

通过下载LSMT2-31160-V数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Power Transducer Series L-UNIT  
MODEL  
MULTI POWER TRANSDUCER  
LSMT2  
MODEL & SUFFIX CODE SELECTION  
120 (4.72)  
LSMT2–❑❑❑❑❑❑  
MODEL  
CONFIGURATION  
1 : 3-phase / 3-wire  
100  
(3.94)  
(See P. 5/10)  
2 : Single-phase / 2-wire (See P. 7/10)  
3 : Single-phase / 3-wire (See P. 8/10)  
128  
(5.04)  
4 : 3-phase / 4-wire  
VOLTAGE INPUT  
0 : None  
(See P. 9/10)  
mm (inch)  
Functions & Features  
1 : 110V AC  
2 : 220V AC  
4 : 380V AC  
A : 100V / 200V AC  
CURRENT INPUT  
0 : None  
1 : 1A AC  
5 : 5A AC  
ZERO-PHASE VOLTAGE INPUT  
0 : None  
1 : 110V AC  
• Converting all major factors required for power  
management into DC outputs • Compact design •  
10 analog outputs and 1 Wh pulse output or Modbus  
output • Saving wiring space • DIN rail mounting  
• Free selection of measuring items, assigned to any  
output channel • Transducer input range is  
selectable with Watt, Var, Power Factor or Fre-  
quency • Linear output for bidirectional current for  
Var and Power Factor • Output characteristics can  
be changed according to Lag/Lead for Var and Power  
Factor  
2 : 190V AC  
Typical Applications  
DC OUTPUT  
Current  
• Monitoring panels  
Voltage  
4 : 0 – 10V DC  
5 : 0 – 5V DC  
6 : 1 – 5V DC  
A : 4 – 20mA DC  
G : 0 – 1mA DC  
GENERAL SPECIFICATIONS  
Construction: stand-alone; terminal access at the front  
Connection  
PULSE / NETWORK OUTPUT  
0 : None (with zero-phase voltage input selected)  
1 : Watthours  
Input and aux. supply: M4 screw terminals  
Output: M3.5 screw terminals  
Screw terminals: nickel-plated brass (torque 0.8 N·m)  
Housing material: flame-resistant resin (black)  
Isolation: voltage input to current input to DC out-  
put or pulse (network) output to aux. sup-  
ply; negatives common to all outputs  
Computation: digital processor  
Output range: approx. 0 – 100% at 1 – 5V  
Zero/span adjustments: ±4% independently adjust-  
able for each measuring item  
M : Modbus  
AUXILIARY POWER SUPPLY  
AC Power  
M : 85 – 264V AC  
DC Power  
R : 24V DC  
V : 48V DC  
P : 110V DC  
ORDERING INFORMATION  
See later pages of this data sheet for detailed infor-  
mation about availability of the functions for each in-  
put configuration.  
Address setting: 0 – 249 selectable (front; default  
001)  
Overrange output limit: high 101%, low -1%  
(resettable)  
Sampling rate: approx. 500 µsec.  
The unit is configured at the factory according to the  
user's specifications, however, measuring items can be  
freely selected and assigned to up to 10 output chan-  
(DO NOT connect directly to inverters.)  
nels via the front panel control switches, except V  
0
:
zero-phase voltage or MV : max. zero-phase voltage  
0
which require specific hardware to be ordered.  
The measuring items are listed below:  
A = Line current  
V = Line voltage  
W = Watt, active power var = var, reactive power  
PF = Power factor  
Hz = Frequency  
V0 = Zero-phase voltage  
MV0 = Maximum zero-phase voltage  
P. 1 / 10  
ES-1954 Rev.6  
LSMT2  
•Watt  
OUT mA  
20  
MODBUS COMMUNICATION  
OUT V  
10  
Standard: Conforms to RS-485, EIA  
Baud rate: 1200, 2400, 4800, 9600, 19.2k bps  
selectable (front)  
Communication: Half-duplex, asynchronous, no  
procedure  
12  
4
5
INP  
1000W  
+1000W  
INP  
0
0
500  
0
0
500  
0
1000W  
+1000W  
Protocol: Modbus RTU  
-1000  
-1000  
Transmission distance: 500 meters max.  
Transmission media: shielded twisted-pair cable  
(CPEV-S 0.9 dia.)  
•Var  
OUT mA  
20  
OUT V  
10  
Refer to the Modbus Protocol Reference Guide (EM-  
5650) for supported functions.  
12  
4
5
INP  
1000var  
(LAG)  
INP  
1000var  
(LAG)  
INPUT & OUTPUT  
INPUT  
0
1000  
(LEAD)  
0
1000  
0
(LEAD)  
Voltage Input (must be balanced for 3-phase)  
Operational range  
Voltage & active/reactive power: 0 – 110% of rating  
Power factor & frequency: 90 – 110% of rating  
Overload capacity: 200% of rating for 10 sec.,  
120% continuous  
•Var for Bidirectional Current  
OUT mA  
OUT V  
10  
20  
12  
4
5
INP  
1000var  
INP  
1000var  
0
1000  
0
1000  
0
1000  
0
1000  
0
(LEAD) (LAG) (LEAD) (LAG)  
REVERSE FLOW DIRECT FLOW  
(LEAD) (LAG) (LEAD) (LAG)  
REVERSE FLOW DIRECT FLOW  
Input burden: 0.2VA/phase for 110V AC  
0.3VA/phase for 220V AC  
•Power Factor  
OUT mA  
20  
OUT V  
10  
0.5VA/phase for 380V AC  
12  
4
Current Input (can be unbalanced for 3-phase)  
Operational range  
Current & active/reactive power: 0 – 120% of rating  
Power factor: 20 – 120% of rating  
Overload capacity: 4000% of rating for 1 sec., 2000%  
for 4 sec., 120% continuous  
5
INP  
0.5  
(LAG)  
INP  
0.5  
(LAG)  
0
0.5  
(LEAD)  
1
0.5  
1
(LEAD)  
When the input voltage is zero or the current is the twentieth or less of  
the rating, the output is either equivalent to power factor 1 or  
0% or less (selectable).  
Input burden: 0.3VA/phase  
•Power Factor for Bidirectional Current  
OUT mA  
OUT V  
10  
20  
12  
4
OUTPUT  
DC Current  
Load resistance  
5
0
INP  
INP  
0
1
0
1
0
0
1
0
1
0
4 – 20mA  
0 – 1mA  
: 600 (maximum)  
: 10k  
(LEAD) (LAG) (LEAD) (LAG)  
REVERSE FLOW DIRECT FLOW  
(LEAD) (LAG) (LEAD) (LAG)  
REVERSE FLOW DIRECT FLOW  
OUT mA  
20  
OUT V  
10  
DC Voltage  
Load resistance  
0 – 10V  
12  
4
5
0
INP  
INP  
: 1000 (minimum)  
: 1000  
: 1000  
0
0.5  
1
0.5  
0
0.5  
1
0.5  
0
0
0.5  
1
0.5  
0
0.5  
1
0.5  
0
(LEAD) (LAG) (LEAD) (LAG)  
REVERSE FLOW DIRECT FLOW  
(LEAD) (LAG) (LEAD) (LAG)  
REVERSE FLOW DIRECT FLOW  
0 – 5V  
1 – 5V  
When the input voltage is zero or the current is the twentieth or less of  
the rating, the output is either equivalent to power factor 1 or  
0% or less (selectable).  
I/O CHARACTERISTICS  
•Frequency  
OUT mA  
20  
OUT V  
10  
•Voltage  
OUT mA  
20  
•Current  
OUT V  
10  
12  
4
5
12  
5
4
INP  
65Hz  
INP  
65Hz  
0
45  
55  
45  
55  
INP  
300V  
INP  
5A  
0
0
150  
0
2.5  
When the input voltage is the fifth or less of the rating, the output  
is equivalent to the input frequency – 2Hz.  
Specifications subject to change without notice.  
P. 2 / 10  
ES-1954 Rev.6  
Assigning Output Channels  
SW1 : ON (Set mode)  
SW6 : ON (Assign mode)  
Rotary SW : Choose the output channel.  
Control buttons : Watching the DATA display show-  
ing measuring item No., press (+) or (–) for changing  
data.  
FRONT PANEL CONFIGURATION  
SELECT Rotary SW  
DATA Display  
FUNCTION SW  
1
2
3
4
5
6
7
8
9
10  
11 12 13  
INSTALLATION  
Auxiliary power supply  
AC:  
DC:  
operational voltage range: 85 – 264V,  
50/60 Hz, approx. 10VA  
operational voltage range: rating ±10%, or  
85 – 150V for 110V rating; ripple 10% p-p  
max.; approx. 10W (90mA at 110V)  
14 16 18 20 22 24 26 28 30 32  
15 17 19 21 23 25 27 29 31 33  
A
C
B
Terminator  
Control Buttons  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 40 to 85% RH (non-condensing)  
Mounting: surface or DIN rail  
DATA display: green LED; 5 mm (.2 in)  
Dimensions: W125×H100×D128 mm (4.72"×3.94"×5.04")  
FUNCTION SW: Used to turn the unit into SET  
Weight:  
600 g (1.3 lbs)  
mode and choose functions.  
SELECT rotary SW: Used to choose output channels,  
programmable items, etc. in Set mode.  
PERFORMANCE in percentage of span  
Accuracy  
Control buttons: Used to increase (+) / decrease (–)  
the values, or move forward (+) / back (–) to other  
items in Set mode.  
Continuously pressing the button increases incre-  
mental speed.  
Voltage, current, watt, var, frequency: ±0.5%  
Power factor: ±1.5%  
Zero-phase voltage: ±1.0%  
Max. zero-phase voltage: ±1.0%  
Watthours: ±2.0% (load current 5 – 100%, power factor 1.0)  
±2.5% (load current 10 – 100%, power  
factor 0.5, lag current)  
OFF  
Run mode  
Output Adj. mode  
Zero adj.  
Measured value output Simulated rated value output  
ON  
SW1  
SW2  
SW3  
SW4  
SW5  
SW6  
Set mode  
Configure mode  
Span adj.  
Temp. conditioning incl. in the accuray: 23 ±10°C  
(73.4 ±18°F)  
Freq. conditioning incl. in the accuracy: rating ±5%  
Response time (0 – 100% ±1%): 1 sec.  
except for zero-phase voltage: 0.1 sec.  
Run mode  
Assign mode  
Ripple:  
1% p-p max.  
Terminator: For Modbus communication.  
Auxiliary supply voltage effect: half the accuracy  
over voltage range  
Power failure protection: VT/CT ratios, watthours,  
max. zero-phase voltage are stored in the  
non-volatile memory.  
PROGRAMMING PROCEDURE (example)  
Zero/Span Adjustments  
SW1 : ON (Set mode)  
SW2 : OFF (Output Adj. mode)  
Insulation resistance: 50Mwith 500V DC  
(voltage input to current input to DC  
output to pulse (network) output to aux.  
supply to ground)  
Dielectric strength: 2000V AC @1 minute  
(circuit to ground; voltage input termi-  
nals to output terminals; aux. supply to  
input or output terminals)  
SW3 : OFF (zero) or ON (span)  
Rotary SW : Choose the output channel.  
Control buttons : Watching the DATA display show-  
ing adjusted value, press (+) for increasing or (–) for  
descreasing the value. Adjustable to ±5%.  
Configuration Change (range, lag/lead, etc.)  
SW1 : ON (Set mode)  
1500V AC @1 minute  
SW2 : ON (Configure mode)  
(output terminals to ground)  
Rotary SW : Choose the item to be programmed.  
Control buttons : Watching the DATA display show-  
ing data No., press (+) or (–) for changing data.  
Surge withstand voltage: 1.2/50 µsec., ±6kV  
(circuit to ground; voltage input termi-  
nals to output terminals)  
P. 3 / 10  
ES-1954 Rev.6  
LSMT2  
CONNECTION DIAGRAM, OUTPUT & AUXILIARY SUPPLY  
AUX SUPPLY  
11 12 13  
E
U(+) V(–)  
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33  
A
+
B
C
+
+
+
+
+
+
+
+
+
+
Pulse Output  
Network Output  
1
2
3
4
5
6
7
8
9
10  
11  
OUTPUT  
+
Output 1 through 10: Analog output  
Output 11: Pulse or network output  
Shielded  
Twisted-pair  
Cable  
To Other  
RS-485 Devices  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENT mm (inch)  
9.2 (.36)  
13–M4 SCREW  
4–5 (.2) dia. HOLE  
DIN RAIL  
35 mm wide  
1
2
3
4
5
6
7
8
9
10  
11 12 13  
14 16 18 20 22 24 26 28 30 32  
15 17 19 21 23 25 27 29 31 33  
A
C
B
23–M3.5 SCREW  
128 (5.04)  
64 (2.52)  
7 (.28)  
[3.3 (.13)]  
8.2 (.32)  
120 (4.72)  
MOUNTING REQUIREMENTS mm (inch)  
64 (2.52)  
4–M4  
125 (4.92) min.  
Specifications subject to change without notice.  
P. 4 / 10  
ES-1954 Rev.6  
MODEL  
3-PHASE / 3-WIRE CONNECTION  
LSMT2-1  
MODEL & SUFFIX CODE SELECTION  
INPUT RANGE  
Voltage  
Current  
LSMT2–1❑❑❑❑❑  
RATING  
110V  
220V  
RANGE  
RATING  
1A  
RANGE  
0 – 1A  
0 – 5A  
MODEL  
0 – 150V  
0 – 300V  
CONFIGURATION  
1 : 3-phase / 3-wire  
VOLTAGE INPUT  
0 : None  
5A  
Active power  
Input range and ± can be changed via the front panel.  
1 : 110V AC  
2 : 220V AC  
CURRENT INPUT *1  
0 : None  
1 : 1A AC  
5 : 5A AC  
*1: Alternative choice of V or current.  
ZERO-PHASE VOLTAGE INPUT (V  
0 : None  
1 : 110V AC  
2 : 190V AC  
DC OUTPUT  
Current  
A : 4 – 20mA DC  
G : 0 – 1mA DC  
RATING  
RANGE  
-100 – +100W  
0 – 100W  
0 – 150W  
0 – 166.6W  
0 – 200W  
0 – 500W  
0 – 750W  
0 – 833W  
0 – 1000W  
0 – 200W  
0 – 300W  
0 – 333.3W  
0 – 400W  
0 – 1000W  
0 – 1500W  
0 – 1666W  
0 – 2000W  
-150 – +150W  
-166.6 – +166.6W  
-200 – +200W  
-500 – +500W  
-750 – +750W  
-833 – +833W  
-1000 – +1000W  
-200 – +200W  
-200 – +200W  
-333.3 – +333.3W  
-400 – +400W  
-1000 – +1000W  
-1500 – +1500W  
-1666 – +1666W  
-2000 – +2000W  
110V / 1A  
0
110V / 5A  
220V / 1A  
0
) *1  
Voltage  
4 : 0 – 10V DC  
5 : 0 – 5V DC  
6 : 1 – 5V DC  
220V / 5A  
PULSE / NETWORK OUTPUT  
0 : None (with zero-phase voltage input selected)  
1 : Watthours  
Reactive power  
Input range and lag/lead can be changed via the front panel.  
M : Modbus  
RATING  
RANGE  
AUXILIARY POWER SUPPLY  
0 – lag 100 var lead 100 – lag 100 var  
0 – lag 150 var lead 150 – lag 150 var  
0 – lag 166.6 var lead 166.6 – lag 166.6 var  
0 – lag 200 var lead 200 – lag 200 var  
0 – lag 500 var lead 500 – lag 500 var  
0 – lag 750 var lead 750 – lag 750 var  
0 – lag 833 var lead 833 – lag 833 var  
0 – lag 1000 var lead 1000 – lag 1000 var  
0 – lag 200 var lead 200 – lag 200 var  
0 – lag 300 var lead 200 – lag 200 var  
0 – lag 333.3 var lead 333.3 – lag 333.3 var  
0 – lag 400 var lead 400 – lag 400 var  
0 – lag 1000 var lead 1000 – lag 1000 var  
0 – lag 1500 var lead 1500 – lag 1500 var  
0 – lag 1666 var lead 1666 – lag 1666 var  
0 – lag 2000 var lead 2000 – lag 2000 var  
AC Power  
DC Power  
110V / 1A  
M : 85 – 264V AC  
R : 24V DC  
V : 48V DC  
P : 110V DC  
110V / 5A  
220V / 1A  
220V / 5A  
ORDERING INFORMATION  
Specify code number and variables (e.g. LSMT2-  
1150A1-M). Use Ordering Information Sheet (No.  
ESU-1954-1).  
The unit is configured at the factory according to the  
user's specifications, however, measuring items can be  
freely selected and assigned to up to 10 output chan-  
nels via the front panel control switches, except that  
V : zero-phase voltage is available only when speci-  
0
fied in ordering.  
The measuring items are listed below:  
Zero-phase voltage  
A = Line current  
W = Watt, active power var = var, reactive power  
PF = Power factor  
V0 = Zero-phase voltage  
V = Line voltage  
RATING  
110V  
190V  
RANGE  
0 – 150V  
0 – 260V  
Hz = Frequency  
P. 5 / 10  
ES-1954 Rev.6  
LSMT2  
Power factor: lead 0.5 – 1 – lag 0.5  
lag 0.5 – 1 – lead 0.5  
lead 0 – 1 – lag 0  
lag 0 – 1 – lead 0  
Input range and lag/lead can be changed via the front panel.  
Frequency: 45 – 55 Hz, 55 – 65 Hz, 45 – 65 Hz  
Input range can be changed via the front panel.  
Watthours  
Ratio: 110V – 77kV at the VT primary  
5 – 8000A at the CT primary  
Pulse unit: 0.01, 0.1, 1, 10, 100, 1000 kWh/pulse  
CONNECTION DIAGRAM, INPUT  
•No Zero-phase Voltage Measuring  
SOURCE  
LOAD  
K
A
A
A
1
2
3
1
2
3
k
V
V
12  
V31  
K
23  
k
V
v
V
v
CT  
CT  
U
u
U
u
VT  
1
2
3
4
5
6
7
8
9
10  
P1 P2 P3  
1S 1L  
3S 3L  
•With Zero-phase Voltage Measuring  
SOURCE  
1
2
3
LOAD  
V
V
12  
23  
V
31  
V
v
V
v
U
u
U
u
GVT3  
7
VT  
1
2
3
4
5
6
8
9
10  
P1 P2 P3  
G1 G4  
Specifications subject to change without notice.  
P. 6 / 10  
ES-1954 Rev.6  
MODEL  
SINGLE-PHASE / 2-WIRE CONNECTION  
LSMT2-2  
MODEL & SUFFIX CODE SELECTION  
INPUT RANGE  
Voltage  
Current  
LSMT2–20❑  
RATING  
110V  
220V  
RANGE  
RATING  
1A  
RANGE  
0 – 1A  
0 – 5A  
MODEL  
0 – 150V  
0 – 300V  
CONFIGURATION  
2 : Single-phase / 2-wire  
VOLTAGE INPUT  
0 : None  
1 : 110V AC  
2 : 220V AC  
5A  
Active power  
Input range and ± can be changed via the front panel.  
RATING  
RANGE  
-50 –  
-75 –  
0 –  
0 –  
50W  
75W  
+50W  
+75W  
CURRENT INPUT  
0 : None  
110V / 1A  
0 – 83.3W  
0 – 100W  
0 – 250W  
0 – 375W  
0 – 417W  
0 – 500W  
0 – 100W  
0 – 150W  
0 – 166.6W  
0 – 200W  
0 – 500W  
0 – 750W  
0 – 833W  
0 – 1000W  
-83.3 – +83.3W  
-100 – +100W  
-250 – +250W  
-375 – +375W  
-417 – +417W  
-500 – +500W  
-100 – +100W  
-150 – +150W  
-166.6 – +166.6W  
-200 – +200W  
-500 – +500W  
-750 – +750W  
-833 – +833W  
-1000 – +1000W  
1 : 1A AC  
5 : 5A AC  
ZERO-PHASE VOLTAGE INPUT (V  
0 : None  
DC OUTPUT  
Current  
A : 4 – 20mA DC  
G : 0 – 1mA DC  
0
)
110V / 5A  
220V / 1A  
220V / 5A  
Voltage  
4 : 0 – 10V DC  
5 : 0 – 5V DC  
6 : 1 – 5V DC  
PULSE / NETWORK OUTPUT  
1 : Watthours  
M : Modbus  
AUXILIARY POWER SUPPLY  
AC Power  
DC Power  
Power factor: lead 0.5 – 1 – lag 0.5  
lag 0.5 – 1 – lead 0.5  
M : 85 – 264V AC  
R : 24V DC  
V : 48V DC  
P : 110V DC  
lead 0 – 1 – lag 0  
lag 0 – 1 – lead 0  
Input range and lag/lead can be changed via the front panel.  
ORDERING INFORMATION  
Specify code number and variables (e.g. LSMT2-  
2150A1-M). Use Ordering Information Sheet (No.  
ESU-1954-2).  
Frequency: 45 – 55 Hz, 55 – 65 Hz, 45 – 65 Hz  
Input range can be changed via the front panel.  
The unit is configured at the factory according to the  
user's specifications, however, measuring items can be  
freely selected and assigned to up to 10 output chan-  
nels via the front panel control switches.  
The measuring items are listed below:  
Watthours  
Ratio: 110V – 77kV at the VT primary  
5 – 8000A at the CT primary  
Pulse unit: 0.01, 0.1, 1, 10, 100, 1000 kWh/pulse  
A = Line current  
W = Watt, active power  
PF = Power factor  
V = Line voltage  
CONNECTION DIAGRAM, INPUT  
Hz = Frequency  
SOURCE  
V
LOAD  
K
A
1
2
k
CT  
U
u
V
v
VT  
1
2
3
4
5
6
7
8
9
10  
P1 P2  
1S 1L  
P. 7 / 10  
ES-1954 Rev.6  
LSMT2  
MODEL  
SINGLE-PHASE / 3-WIRE CONNECTION  
LSMT2-3  
MODEL & SUFFIX CODE SELECTION  
INPUT RANGE  
Voltage  
Current  
LSMT2–30❑  
RATING  
100V  
200V  
RANGE  
RATING  
1A  
RANGE  
0 – 1A  
0 – 5A  
MODEL  
0 – 150V  
0 – 300V  
CONFIGURATION  
3 : Single-phase / 3-wire  
VOLTAGE INPUT  
0 : None  
5A  
Active power  
Input range and ± can be changed via the front panel.  
A : 100V / 200V AC  
CURRENT INPUT  
0 : None  
1 : 1A AC  
5 : 5A AC  
ZERO-PHASE VOLTAGE INPUT (V  
0 : None  
DC OUTPUT  
Current  
RATING  
RANGE  
-100 – +100W  
0 – 100W  
0 – 150W  
0 – 166.6W  
0 – 200W  
0 – 500W  
0 – 750W  
0 – 833W  
0 – 1000W  
-150 – +150W  
-166.6 – +166.6W  
-200 – +200W  
-500 – +500W  
-750 – +750W  
-833 – +833W  
-1000 – +1000W  
100/200V / 1A  
0
)
100/200V / 5A  
Voltage  
4 : 0 – 10V DC  
5 : 0 – 5V DC  
6 : 1 – 5V DC  
A : 4 – 20mA DC  
G : 0 – 1mA DC  
Power factor: lead 0.5 – 1 – lag 0.5  
lag 0.5 – 1 – lead 0.5  
lead 0 – 1 – lag 0  
lag 0 – 1 – lead 0  
Input range and lag/lead can be changed via the front panel.  
PULSE / NETWORK OUTPUT  
1 : Watthours  
M : Modbus  
AUXILIARY POWER SUPPLY  
AC Power  
DC Power  
Frequency: 45 – 55 Hz, 55 – 65 Hz, 45 – 65 Hz  
Input range can be changed via the front panel.  
M : 85 – 264V AC  
R : 24V DC  
V : 48V DC  
P : 110V DC  
Watthours  
Ratio: 110V at the VT primary  
5 – 8000A at the CT primary  
Pulse unit: 0.01, 0.1, 1, 10, 100, 1000 kWh/pulse  
ORDERING INFORMATION  
Specify code number and variables (e.g. LSMT2-  
3A50A1-M). Use Ordering Information Sheet (No.  
ESU-1954-3).  
CONNECTION DIAGRAM, INPUT  
The unit is configured at the factory according to the  
user's specifications, however, measuring items can be  
freely selected and assigned to up to 10 output chan-  
nels via the front panel control switches.  
The measuring items are listed below:  
SOURCE  
LOAD  
K
A
A
A
1
N
2
1
N
2
k
V
V
1N  
V12  
K
2N  
k
V
v
V
v
CT  
CT  
U
u
U
u
VT  
A = Line current  
W = Watt, active power  
PF = Power factor  
V = Line voltage  
1
2
3
4
5
6
7
8
9
10  
P1 P0 P2  
1S 1L  
2S 2L  
Hz = Frequency  
Specifications subject to change without notice.  
P. 8 / 10  
ES-1954 Rev.6  
MODEL  
3-PHASE / 4-WIRE CONNECTION  
LSMT2-4  
MODEL & SUFFIX CODE SELECTION  
INPUT RANGE  
Voltage  
LSMT2–40❑  
RATING  
110V  
3  
PHASE VOLTAGE  
LINE VOLTAGE  
MODEL  
0 – 150V  
3  
0 – 300V  
3  
0 – 450V  
3  
CONFIGURATION  
4 : 3-phase / 4-wire  
VOLTAGE INPUT  
0 : None  
0 – 150V  
220V  
3  
380V  
3  
0 – 300V  
0 – 450V  
110V  
3  
220V  
3  
380V  
3  
1 :  
2 :  
4 :  
/ 110V AC  
/ 220V AC  
/ 380V AC  
Current  
RATING  
1A  
RANGE  
0 – 1A  
0 – 5A  
5A  
CURRENT INPUT  
0 : None  
1 : 1A AC  
Active power  
Input range and ± can be changed via the front panel.  
5 : 5A AC  
ZERO-PHASE VOLTAGE INPUT (V  
RATING  
RANGE  
-100 – +100W  
0 – 100W  
0 – 150W  
0 – 166.6W  
0 – 200W  
0 – 500W  
0 – 750W  
0 – 833W  
0 – 1000W  
0 – 200W  
0 – 300W  
0 – 333.3W  
0 – 400W  
0 – 1000W  
0 – 1500W  
0 – 1666W  
0 – 2000W  
0 – 350W  
0 – 525W  
0 – 583W  
0 – 700W  
0 – 1750W  
0 – 2625W  
0 – 2917W  
0 – 3500W  
0
)
110V  
/ 1A  
3  
-150 – +150W  
-166.6 – +166.6W  
-200 – +200W  
-500 – +500W  
-750 – +750W  
-833 – +833W  
-1000 – +1000W  
-200 – +200W  
-200 – +200W  
-333.3 – +333.3W  
-400 – +400W  
-1000 – +1000W  
-1500 – +1500W  
-1666 – +1666W  
-2000 – +2000W  
-350 – +350W  
-525 – +525W  
-583 – +583W  
-700 – +700W  
-1750 – +1750W  
-2625 – +2625W  
-2917 – +2917W  
-3500 – +3500W  
0 : None  
DC OUTPUT  
Current  
A : 4 – 20mA DC  
G : 0 – 1mA DC  
Voltage  
4 : 0 – 10V DC  
5 : 0 – 5V DC  
6 : 1 – 5V DC  
110V  
/ 5A  
3  
PULSE / NETWORK OUTPUT  
1 : Watthours  
M : Modbus  
AUXILIARY POWER SUPPLY  
AC Power  
220V  
/ 1A  
3  
DC Power  
M : 85 – 264V AC  
R : 24V DC  
V : 48V DC  
P : 110V DC  
220V  
/ 5A  
3  
ORDERING INFORMATION  
380V  
/ 1A  
3  
Specify code number and variables (e.g. LSMT2-  
4150A1-M). Use Ordering Information Sheet (No.  
ESU-1954-4).  
The unit is configured at the factory according to the  
user's specifications, however, measuring items can be  
freely selected and assigned to up to 10 output chan-  
nels via the front panel control switches.  
The measuring items are listed below:  
380V  
/ 5A  
3  
A = Line current  
W = Watt, active power var = var, reactive power  
PF = Power factor Hz = Frequency  
V = Line voltage  
P. 9 / 10  
ES-1954 Rev.6  
LSMT2  
Reactive power  
Input range and lag/lead can be changed via the front panel.  
RATING  
RANGE  
0 – lag 100 var lead 100 – lag 100 var  
0 – lag 150 var lead 150 – lag 150 var  
0 – lag 166.6 var lead 166.6 – lag 166.6 var  
0 – lag 200 var lead 200 – lag 200 var  
0 – lag 500 var lead 500 – lag 500 var  
0 – lag 750 var lead 750 – lag 750 var  
0 – lag 833 var lead 833 – lag 833 var  
0 – lag 1000 var lead 1000 – lag 1000 var  
0 – lag 200 var lead 200 – lag 200 var  
0 – lag 300 var lead 200 – lag 200 var  
0 – lag 333.3 var lead 333.3 – lag 333.3 var  
0 – lag 400 var lead 400 – lag 400 var  
0 – lag 1000 var lead 1000 – lag 1000 var  
0 – lag 1500 var lead 1500 – lag 1500 var  
0 – lag 1666 var lead 1666 – lag 1666 var  
0 – lag 2000 var lead 2000 – lag 2000 var  
0 – lag 350 var lead 350 – lag 350 var  
0 – lag 525 var lead 525 – lag 525 var  
0 – lag 583 var lead 583 – lag 583 var  
0 – lag 700 var lead 700 – lag 700 var  
0 – lag 1750 var lead 1750 – lag 1750 var  
0 – lag 2625 var lead 2625 – lag 2625 var  
0 – lag 2917 var lead 2917 – lag 2917 var  
0 – lag 3500 var lead 3500 – lag 3500 var  
110V  
/ 1A  
3  
110V  
/ 5A  
3  
220V  
/ 1A  
3  
220V  
/ 5A  
3  
380V  
/ 1A  
3  
380V  
/ 5A  
3  
Power factor: lead 0.5 – 1 – lag 0.5  
lag 0.5 – 1 – lead 0.5  
lead 0 – 1 – lag 0  
lag 0 – 1 – lead 0  
Input range and lag/lead can be changed via the front panel.  
Frequency: 45 – 55 Hz, 55 – 65 Hz, 45 – 65 Hz  
Input range can be changed via the front panel.  
Watthours  
Ratio: 110V – 77kV at the VT primary  
5 – 8000A at the CT primary  
Pulse unit: 0.01, 0.1, 1, 10, 100, 1000 kWh/pulse  
CONNECTION DIAGRAM, INPUT  
SOURCE  
LOAD  
K
A
A
A
1
2
3
1
2
3
K
k
V
1
V
12  
23  
V31  
K
k
V2  
V
k
V
3
N
V
v
U
u
CT  
CT  
CT  
U
u
V
v
VT  
1
2
3
4
5
6
7
8
9
10  
P1  
P3 P0 1S 1L 2S 2L 3S 3L  
Specifications subject to change without notice.  
P. 10 / 10  
ES-1954 Rev.6  

LSMT2-31160-V 相关器件

型号 制造商 描述 价格 文档
LSMT2-31161-M MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-31161-P MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-31161-R MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-31161-V MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-311A0-M MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-311A0-P MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-311A0-R MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-311A0-V MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-311A1-M MSYSTEM MULTI POWER TRANSDUCER 获取价格
LSMT2-311A1-P MSYSTEM MULTI POWER TRANSDUCER 获取价格

LSMT2-31160-V 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8