LTRPN-412PJW/T

更新时间:2024-10-29 22:49:02
品牌:MSYSTEM
描述:Power Transducer Series LT-UNIT

LTRPN-412PJW/T 概述

Power Transducer Series LT-UNIT

LTRPN-412PJW/T 数据手册

通过下载LTRPN-412PJW/T数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: LTRPN  
2: 220 V AC  
Power Transducer Series LT-UNIT  
4: 220 V / 380 V AC (3-phase/4-wire only)  
VAR TRANSDUCER  
(self-powered)  
[3] CT INPUT (unbalanced load)  
Current  
1: 1 A AC  
2: 2 A AC  
5: 5 A AC  
Functions & Features  
• Providing a DC output signal in proportion to AC reactive  
power  
• DC output containing little ripple is ideal for computer  
input  
• "Time division multiplication" method accepts distorted  
waveforms  
[4] OUTPUT SIGNAL POLARITY  
P: Negative in lag, positive in lead  
• Isolation up to 2000 V AC  
• High-density mounting  
M: Negative in lead, positive in lag  
• Conforms to IEC 60688  
[5] OUTPUT  
• No auxiliary power supply required  
Current  
A: 4 – 20 mA DC (Load resistance 500 Ω max.)  
FW: -10 – +10 mA DC (Load resistance 1000 Ω max.)  
GW: -1 – +1 mA DC (Load resistance 10 kΩ max.)  
JW: -5 – +5 mA DC (Load resistance 2000 Ω max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
Typical Applications  
• Centralized monitoring and control of power management  
system in a manufacturing facility or building  
72  
(2.83)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
1W: -10 – +10 mV DC (Load resistance 10 kΩ min.)  
2W: -100 – +100 mV DC (Load resistance 100 kΩ min.)  
3W: -1 – +1 V DC (Load resistance 1000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
111  
(4.37)  
143 (5.63)  
mm (inch)  
[6] OPTIONS (multiple selections)  
Terminal Cover  
blank: Without  
MODEL: LTRPN–[1][2][3][4][5][6]  
/T: With  
Other Options  
ORDERING INFORMATION  
• Code number: LTRPN–[1][2][3][4][5][6]  
Specify a code from below for each of [1] through [6].  
(e.g. LTRPN-115PA/T/Q)  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01)  
/C02: Polyurethane coating  
• Use Ordering Information Sheet (No. ESU-3355).  
/C03: Rubber coating  
[1] CONFIGURATION  
1: 3-phase / 3-wire  
GENERAL SPECIFICATIONS  
Connection: M4 screw terminals (torque 1.2 N·m)  
4: 3-phase / 4-wire  
Screw terminal: Chrome-plated steel  
Housing material: Flame-resistant resin (black)  
Isolation: Voltage input to current input to output  
Computation: Time division multiplication  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
[2] VT INPUT (balanced load)  
For 3-phase / 4-wire, phase voltages (e.g. 110 V / √3 ) are used.  
1: 110 V AC  
LTRPN SPECIFICATIONS  
ES-3358 Rev.10 Page 1/3  
https://www.m-system.co.jp/  
MODEL: LTRPN  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max. at ≥ 0.5 V  
OPERATION DIAGRAM (example)  
INPUT SPECIFICATIONS  
Frequency: 50 or 60 Hz  
Negative in lag, positive in lead  
OUT  
20mA  
OUT  
+10V  
VOLTAGE INPUT  
Operational range: 85 – 110 % of rating  
Overload capacity: 150 % of rating for 10 sec., 110 %  
continuous  
12  
4
0
CURRENT INPUT  
-10V  
1000  
(Lag)  
1000  
(Lag)  
0
1000var  
(Lead)  
0
1000var  
(Lead)  
Operational range: 0 – 120 % of rating  
Overload capacity: 4000 % of rating for 1 sec., 2000 % for 4  
sec., 120 % continuous  
Negative in lead, positive in lag  
OUT  
20mA  
OUT  
+10V  
How To Determine Var Range  
Calibration Range [var] = (Measuring Range) ÷  
((VT Ratio) × (CT Ratio))  
12  
4
0
Check that the required calibration range is within the  
available range in the table.  
-10V  
1000  
(Lag)  
0
1000var  
(Lead)  
1000  
(Lag)  
0
1000var  
(Lead)  
[example]  
3-phase / 3-wire, measuring range 75 kvar,  
VT 220 / 110 V, CT 250 / 5 A  
INSTALLATION  
(75 × 10 [var])÷((220 ÷ 110) × (250 ÷ 5))= 750 [var]  
3
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 85 %RH (non-condensing)  
Mounting: Surface or DIN rail  
• 3-phase / 3-wire  
INPUT  
VT / CT  
STD.RANGE  
CODE  
BURDEN (VA)  
USABLE RANGE  
VT  
CT  
Weight: 450 g (0.99 lb)  
1 / 1  
1 / 2  
1 / 5  
2 / 1  
2 / 2  
2 / 5  
200 var  
400 var  
1000 var  
400 var  
800 var  
2000 var  
100 – 240 var  
200 – 480 var  
500 – 1200 var  
200 – 480 var  
400 – 960 var  
1000 – 2400 var  
0.1/ph  
0.2/ph  
0.5/ph  
0.1/ph  
0.2/ph  
0.5/ph  
P1: 2.5  
P3: 0.2  
PERFORMANCE in percentage of span  
Accuracy: ±0.5 % (at 23°C ±10°C or 73.4°F ±18°F,  
45 – 65 Hz)  
P1: 2.5  
P3: 0.4  
Magnetic field (ext. origin) effect: ± 0.5 % (400 A/m)  
Response time: ≤ 2 sec. (0 – 100 % ±1 %)  
Ripple: 0.5 %p-p max.  
• 3-phase / 4-wire  
INPUT  
VT / CT  
STD.RANGE  
CODE  
BURDEN (VA)  
VT CT  
USABLE RANGE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @ 1 minute  
(voltage input to current input to output to ground)  
Impulse withstand voltage: 1.2 / 50 μsec., ±5 kV  
(input to output or ground)  
1 / 1  
1 / 2  
1 / 5  
2 / 1  
2 / 2  
2 / 5  
4 / 1  
4 / 2  
4 / 5  
200 var  
400 var  
1000 var  
400 var  
800 var  
2000 var  
800 var  
1600 var  
4000 var  
100 – 240 var  
200 – 480 var  
500 – 1200 var  
200 – 480 var  
400 – 960 var  
1000 – 2400 var  
400 – 880 var  
800 – 1760 var  
2000 – 4400 var  
P1 – P2 0.1/ph  
: 2.5  
0.2/ph  
P3: 0.1 0.5/ph  
P1 – P2 0.1/ph  
: 2.5  
0.2/ph  
P3: 0.3 0.5/ph  
P1: 2.5 0.1/ph  
P2: 0.4 0.2/ph  
P3: 0.4 0.5/ph  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
OUTPUT SPECIFICATIONS  
■ DC Current: -10 – +20 mA DC  
Span: Min. 1 mA, max. 20 mA  
Measurement Category II (input)  
Pollution Degree 2  
Offset: Max. 1.5 times span  
Input to output: Reinforced insulation (300 V)  
RoHS Directive  
Load resistance: Output drive 10 V max.  
DC Voltage: -10 – +12 V DC  
LTRPN SPECIFICATIONS  
ES-3358 Rev.10 Page 2/3  
https://www.m-system.co.jp/  
MODEL: LTRPN  
CONNECTION DIAGRAM  
3-PHASE/3-WIRE  
3-PHASE/4-WIRE  
SOURCE  
SOURCE  
1
2
3
N
1
2
3
VT  
VT  
FUSE  
FUSE  
U
u
P1  
P2  
P3  
U
V
u
v
P1  
P2  
P3  
P0  
7
8
9
11  
12  
7
8
11  
12  
+
+
OUTPUT  
OUTPUT  
V
V
v
v
U
V
u
v
9
U
V
u
v
U
u
K
K
10  
K
K
K
k
1S  
1L  
3S  
3L  
1
2
5
6
k
k
1S  
1L  
2S  
2L  
3S  
3L  
1
2
3
4
5
6
CT  
k
k
CT  
l
l
L
L
l
l
l
L
L
L
LOAD  
LOAD  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
10 (.39)  
16–M4 SCREW  
2–M4 MTG HOLE  
TERMINAL COVER (option /T)  
DIN RAIL  
35mm wide  
1
2
3
4
5
6
7
8
9
10  
11 12 13 14 15 16  
8 (.31)  
[4 (.16)]  
54 (2.13)  
72 (2.83)  
3
(.12)  
143 (5.63)  
• When mounting, no extra space is needed between units.  
Specifications are subject to change without notice.  
LTRPN SPECIFICATIONS  
ES-3358 Rev.10 Page 3/3  
https://www.m-system.co.jp/  

LTRPN-412PJW/T 相关器件

型号 制造商 描述 价格 文档
LTRPN-415M1W MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M1W/Q MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M1W/T MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M2W MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M2W/Q MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M2W/T MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M3W MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M3W/Q MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M3W/T MSYSTEM Power Transducer Series LT-UNIT 获取价格
LTRPN-415M4W MSYSTEM Power Transducer Series LT-UNIT 获取价格

LTRPN-412PJW/T 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8