MODEL: M1EAXV-2  
2 Channel Super-mini Signal Conditioners  
with Display M1E-2 Series  
NO. OF CHANNELS  
2: 2 channels  
INPUT – Field-selectable  
◆ DC Input  
DC ALARM  
(2 channels, PC programmable, dual or quad alarm trip)  
Current input: 0 - 50 mA DC  
Voltage input: -1000 - +1000 mV DC  
Voltage input: -10 - +10 V DC  
Functions & Features  
• Provides relay outputs at preset DC input levels  
• Quad or dual trip  
• 2 Channels  
• Front LCD display indicating values in scaled engineering  
unit range is used to program the module  
• Adjustable deadband (hysteresis)  
• ON delay time selectable  
[1] OUTPUT  
2: 4 points; N.O. or make contact  
3: 4 points; N.C. or break contact  
5: 2 points; SPDT or transfer contact  
• Hi/Lo trip and energized/de-energized coil independently  
selectable for each setpoint  
POWER INPUT  
• Settable with front buttons  
DC Power  
• Enclosed relays  
R: 24 V DC  
• Relays can be powered by 200 V AC and 100 V DC  
• High-density mounting on DIN rail  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Typical Applications  
• Annunciator  
[2] OPTIONS  
blank: none  
• Various alarm applications  
/Q: With options (specify the specification)  
36 (1.42)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
99  
(3.90)  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-5995)  
125 (4.92)  
RELATED PRODUCTS  
mm (inch)  
• Installation base (model: M1E-BS2)  
Note: The !gure shows the combination  
of the unit and the base.  
• M1EA configurator software (model: M1EACFG)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual (EM-5994) for the M1EA configurator for  
applicable cable types.  
MODEL: M1EAXV–2-[1]-R[2]  
ORDERING INFORMATION  
• Code number: M1EAXV-2-[1]-R[2]  
Specify a code from below for each of [1] and [2].  
(e.g. M1EAXV-2-2-R/Q)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
• Connected to base with connector  
• Base  
M2.6 screw terminals (torque: 0.5 N·m)  
Applicable solderless terminal size (M3)  
Screw terminal: Nickel-plated steel  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 1/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
Housing material: Flame-resistant resin (black)  
Isolation:  
Wide Spans (V)  
Input range: -10 – +10 V DC  
Minimum span: 1 V  
• Output code 2, 3: Ch1 input to Ch2 input to 1L1 or 1L2  
alarm output to 1L3 or 1L4 alarm output to 2L1 or 2L2 alarm  
output to 2L3 or 2L4 alarm output to power  
• Output code 5: Ch1 input to Ch2 input to 1L1 alarm output  
to 1L2 alarm output to 2L1 alarm output to 2L2 alarm  
output to power  
Input resistance: 1 MΩ minimum  
The measurement available for -5 - +105% of input setting  
range.  
OUTPUT SPECIFICATIONS  
Relay rating: 100 V AC @ 0.5 A (cos ø = 1)  
120 V AC @ 0.5 A (cos ø = 1)  
Configuration: Program with front buttons or Via PC.  
Programmable features include: Refer to the parameter list.  
Configurator connection: 2.5 dia. miniature jack;  
RS-232-C level  
240 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 1 A (resistive load)  
■Recommended solderless terminal size - M3 (unit: mm)  
Maximum switching voltage: 250 V AC or 125 V DC  
Maximum switching power: 120 VA or 30 W  
Minimum load: 5 V DC @ 1 mA  
3max  
4min  
3.2 dia.  
Mechanical life: 5 × 10 cycles  
7
Alarm Trip Operation  
• Example Quad N.O. contacts (LL, L, H, HH)  
12max  
(mm)  
L1  
L2  
L3  
L4  
ON OFF  
ON OFF  
OFF ON  
OFF ON  
DISPLAY  
Display functions: Displays and sets measured range,  
engineering unit  
Input  
%
Display size: Approx. 15.6 × 20.8 mm (0.61” × 0.82”)  
Number of pixels: 68 × 95 (horizontal × vertical)  
Character color: Yellow (reversing display of the current  
value and the alarm setting value when alarm is tripped)  
Display life: Approx. 50000 hours  
0
50  
100  
LL  
L
H
HH  
Trip operation in power failure  
Output code 2: All relays turn OFF.  
Output code 3: All relays turn ON.  
Output code 5: Terminals 13 – 15, 16 – 18, 6 – 12,  
1 – 7 turn ON.  
(Expected time for the Display brightness to be reduced to  
50 % when the Display is used continuously with brightness  
setting 2 in 25 ℃)  
Display type: OEL display  
INSTALLATION  
Power consumption  
Display digit: Negative 5 digits, positive 6 digits (-99999 to  
999999)  
DC: ≤ 6 W  
Decimal point position: Selectable  
Operating temperature: -5 to +55°C (23 to 131°F)  
Storage temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 10 to 85 %RH (non-condensing)  
Mounting: Surface or DIN rail  
INPUT SPECIFICATIONS  
Input ranges are shown below.  
For setting change of the input range and setting value,  
refer to the operating manual (EM-5995-B).  
DC Current  
Weight: 150 g (0.33 lb) except base  
PERFORMANCE in percentage of FS input  
Accuracy (display accuracy, setting accuracy):  
± (0.1% of FS + 1 digit)  
Input resistance: Incorporated (28 Ω)  
Input range: 0 - 50 mA DC  
Minimum span: 2 mA  
See CALCULATION EXAMPLES OF OVERALL ACCURACY.  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time (Filter time constant: 0 sec.): ≤ 0.5 sec.  
(0 – 100 % at 90 % setpoint)  
The measurement available for -5 - +105% of input setting  
range.  
DC Voltage  
Narrow Spans (mV)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength:  
Input range: -1000 – +1000 mV DC  
Minimum span: 100 mV  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 2/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
• Output code 2, 3: 1500 V AC @ 1 minute (Ch1 input to  
Ch2 input to 1L1 or 1L2 alarm output to 1L3 or 1L4 alarm  
output to 2L1 or 2L2 alarm output to 2L3 or 2L4 alarm  
output to power to ground)  
• Output code 5: 1500 V AC @ 1 minute (Ch1 input to Ch2  
input to 1L1 alarm output to 1L2 alarm output to 2L1 alarm  
output to 2L2 alarm output to power to ground  
CALCULATION EXAMPLES OF OVERALL ACCURACY  
[Example] Input Range -10 – +10 V, Input Setting -5 – +5 V  
• Accuracy = Input Range Span (20 V) ÷ Input Span Setting  
(10 V) × 0.1 % = ±0.2 % + 1 digit  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
Measurement Category II (output)  
Pollution Degree 2  
• Output code 2, 3  
Input or output to power: Reinforced insulation (300 V)  
Input to output: Basic insulation (300 V)  
1L1 or 1L2 alarm output to 1L3 or 1L4 alarm output to 2L1  
or 2L2 alarm output to 2L3 or 2L4 alarm output: Basic  
insulation (300 V)  
• Output code 5  
Input or output to power: Reinforced insulation (300 V)  
Input to output: Basic insulation (300 V)  
1L1 alarm output to 1L2 alarm output to 2L1 alarm output  
to 2L2 alarm output: Basic insulation (300 V)  
RoHS Directive  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 3/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
EXTERNAL VIEW  
Display  
Up Button  
Down Button  
Set Button  
Mode Button  
Configurator Jack  
COMPONENT FUNCTION  
COMPONENT  
Display  
FUNCTION  
Indicates present values, setting values and abnormal information.  
Two types of present values are displayed respectively at the upper and lower parts according to setting.  
Mode button  
Set button  
Shifts from Measuring mode to each setting mode.  
The destination changes depending on how long the button is held down.  
Pressing Mode button for ≥ 2 seconds returns to Measuring mode from each setting mode..  
Shifts the setting value of each setting parameter item to a setting changeable state.  
When at setting changeable state, used to move through the digits of setting value and to enter (save) the set-  
ting value.  
Cancels Ch1’s and Ch2’s alarm latches in Measuring mode (hold down for ≥ 2 seconds).  
Up button  
Shifts through setting parameter items and to increase or select the setting value.  
Cancels Ch1’s latched alarm in Measuring mode (hold down for ≥ 2 seconds).  
Down button  
Con€gurator Jack  
Shifts through setting parameter items and to decrease or select the setting value.  
Cancels Ch2’s latched alarm in Measuring mode (hold down for ≥ 2 seconds).  
Used to perform con€guration with M1EA con€gurator software (model: M1EACFG).  
When using the software, set the Lockout setting of the unit to ‘Lock.  
Refer to the operating manual (EM-5995-B) for detailed procedures.  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 4/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
TERMINAL ASSIGNMENTS  
1
6
2
7
3
8
4
9
5
10  
11  
16  
12  
17  
13  
18  
14  
19  
15  
20  
• OUTPUT CODE: 2, 3  
• OUTPUT CODE: 5  
No. FUNCTION  
No. FUNCTION  
No. FUNCTION  
No. FUNCTION  
1
2
COM4 (2L3, 2L4)  
2L3 Alarm output  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
2L1 Alarm output  
1
2
COM4 (2L2)  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
N.O. (2L1)  
N.C. (2L1)  
COM1 (1L1)  
N.O. (1L1)  
N.C. (1L1)  
COM2 (1L2)  
N.O. (1L2)  
N.C. (1L2)  
Power +  
2L2 Alarm output  
COM1 (1L1, 1L2)  
1L1 Alarm output  
1L2 Alarm output  
COM2 (1L3, 1L4)  
1L3 Alarm output  
1L4 Alarm output  
Power +  
N.O. (2L2)  
3
Ch1 Input voltage +  
Ch1 Input current +  
Ch1 Input –  
3
Ch1 Input voltage +  
Ch1 Input current +  
Ch1 Input –  
4
4
5
5
6
COM3 (2L1, 2L2)  
2L4 Alarm output  
Ch2 Input voltage +  
Ch2 Input current +  
Ch2 Input –  
6
COM3 (2L1)  
7
7
N.C. (2L2)  
8
8
Ch2 Input voltage +  
Ch2 Input current +  
Ch2 Input –  
9
9
10  
Power –  
10  
Power –  
* Base does not come with the unit. Please order separately.  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 5/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
PARAMETER LIST  
The following parameters can be set or checked, by the front button operation, or from the PC by using M1EA conguration  
software (model: M1EACFG).  
MODE  
ITEM SETTING PARAMETER  
RANGE  
UNIT  
INITIAL VALUE  
Lock  
Ch1 setting  
01  
11  
Lockout setting  
Ch1 Input range  
Lock / Unlock  
0 – 50 mA  
-1000 – +1000 mV  
-10 – +10 V  
0 – 50 mA  
12  
13  
Ch1 0 % input setting  
0.00 – 48.00  
-1000.0 – 900.0  
-10.000 – 9.000  
mA  
mV  
V
4.00  
Ch1 100 % input setting  
2.00 – 50.00  
-900.0 – 1000.0  
-9.000 – 10.000  
mA  
mV  
V
20.00  
14  
15  
16  
Ch1 0 % input scaling  
Ch1 100 % input scaling  
Ch1 Input decimal point  
-99999 – 999999  
-99999 – 999999  
0.00  
100.00  
No decimal point  
The number of decimal places : 1 – 5  
2 places of decimals  
17  
30  
31  
32  
33  
34  
40  
41  
Ch1 Unit (INP Scaling)  
Ch1 L1 alarm enable  
Ch1 L1 alarm setpoint  
Ch1 L1 trip action  
Choose from 68 types  
Disable / Enable  
*
%
Enable  
20.00  
Low  
-99999 – 999999  
High / Low  
*
Ch1 L1 deadband  
0 – 999999  
*
0.01  
Ch1 L1 coil at alarm  
Ch1 L2 alarm enable  
Ch1 L2 alarm setpoint  
Energized / De-energized  
Disable / Enable  
Energized  
Enable  
-99999 – 999999  
*
80.00 (2 points alarm)  
30.00 (4 points alarm)  
42  
Ch1 L2 trip action  
High / Low  
High (2 points alarm)  
Low (4 points alarm)  
43  
44  
50  
51  
52  
53  
54  
60  
61  
62  
63  
64  
70  
71  
72  
79  
80  
81  
89  
Ch1 L2 deadband  
Ch1 L2 coil at alarm  
Ch1 L3 alarm enable  
Ch1 L3 alarm setpoint  
Ch1 L3 trip action  
0 – 999999  
*
0.01  
Energized / De-energized  
Disable / Enable  
Energized  
Enable  
70.00  
High  
-99999 – 999999  
High / Low  
*
Ch1 L3 deadband  
Ch1 L3 coil at alarm  
Ch1 L4 alarm enable  
Ch1 L4 alarm setpoint  
Ch1 L4 trip action  
0 – 999999  
*
0.01  
Energized / De-energized  
Disable / Enable  
Energized  
Enable  
80.00  
High  
-99999 – 999999  
High / Low  
*
Ch1 L4 deadband  
Ch1 L4 coil at alarm  
0 – 999999  
*
0.01  
Energized / De-energized  
Energized  
0
Ch1 Alarm ON-delay time 0 – 999  
Ch1 Power ON-delay time 0 – 999  
sec.  
sec.  
5
Ch1 Latching alarm  
Disable / Enable  
0 – 30  
Disable  
0
Ch1 Filter time constant  
sec.  
%
Ch1 Input Zero ne adjust -5.000 – 5.000  
Ch1 Input Span ne adjust 95.000 – 105.000  
0.000  
100.000  
Cancel  
%
Ch1 Alarm test  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 6/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
MODE  
ITEM SETTING PARAMETER  
111 Ch2 Input range  
RANGE  
UNIT  
INITIAL VALUE  
0 – 50 mA  
Ch2 setting  
0 – 50 mA  
-1000 – +1000 mV  
-10 – +10 V  
112 Ch2 0 % input setting  
113 Ch2 100 % input setting  
0.00 – 48.00  
-1000.0 – 900.0  
-10.000 – 9.000  
mA  
mV  
V
4.00  
2.00 – 50.00  
-900.0 – 1000.0  
-9.000 – 10.000  
mA  
mV  
V
20.00  
114 Ch2 0 % input scaling  
115 Ch2 100 % input scaling  
116 Ch2 Input decimal point  
-99999 – 999999  
-99999 – 999999  
0.00  
100.00  
No decimal point  
The number of decimal places : 1 – 5  
2 places of decimals  
117 Ch2 Unit (INP Scaling)  
130 Ch2 L1 alarm enable  
131 Ch2 L1 alarm setpoint  
132 Ch2 L1 trip action  
Choose from 68 types  
Disable / Enable  
*
%
Enable  
20.00  
Low  
-99999 – 999999  
High / Low  
*
133 Ch2 L1 deadband  
0 – 999999  
*
0.01  
134 Ch2 L1 coil at alarm  
140 Ch2 L2 alarm enable  
141 Ch2 L2 alarm setpoint  
Energized / De-energized  
Disable / Enable  
Energized  
Enable  
-99999 – 999999  
*
80.00 (2 points alarm)  
30.00 (4 points alarm)  
142 Ch2 L2 trip action  
High / Low  
High (2 points alarm)  
Low (4 points alarm)  
143 Ch2 L2 deadband  
144 Ch2 L2 coil at alarm  
150 Ch2 L3 alarm enable  
151 Ch2 L3 alarm setpoint  
152 Ch2 L3 trip action  
153 Ch1 L3 deadband  
154 Ch2 L3 coil at alarm  
160 Ch2 L4 alarm enable  
161 Ch2 L4 alarm setpoint  
162 Ch2 L4 trip action  
163 Ch2 L4 deadband  
164 Ch2 L4 coil at alarm  
0 – 999999  
*
0.01  
Energized / De-energized  
Disable / Enable  
Energized  
Enable  
70.00  
High  
-99999 – 999999  
High / Low  
*
0 – 999999  
*
0.01  
Energized / De-energized  
Disable / Enable  
Energized  
Enable  
80.00  
High  
-99999 – 999999  
High / Low  
*
0 – 999999  
*
0.01  
Energized / De-energized  
Energized  
0
170 Ch2 Alarm ON-delay time 0 – 999  
171 Ch2 Power ON-delay time 0 – 999  
sec.  
sec.  
5
172 Ch2 Latching alarm  
Disable / Enable  
0 – 30  
Disable  
0
179 Ch2 Filter time constant  
sec.  
%
180 Ch2 Input Zero !ne adjust -5.000 – 5.000  
181 Ch2 Input Span !ne adjust 95.000 – 105.000  
0.000  
100.000  
Cancel  
Lock  
%
189 Ch2 Alarm test  
01 Lockout setting  
Lock / Unlock  
Advanced  
201 Display setting  
Upper: choose from 14 types*  
Lower: choose from 15 types*  
Upper: Ch1 ALARM  
(Scaling)  
Lower: Ch2 ALARM  
(Scaling)  
202 Channel enable  
Choose from 3 types  
Ch1 enable  
Ch2 enable  
203 Brightness  
1 (darkest) — 4 (brightest)  
0 (always on), 1 — 60  
OFF / RESET  
min  
4
204 Display timeout  
205 Reset all settings  
206 Version indication  
10  
OFF  
01  
Lockout setting  
Lock / Unlock  
Lock  
* For details, refer to the operating manual (EM-5995-B).  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 7/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
125 (4.92)  
[4 (.16)]  
45 (1.77)  
36 (1.42)  
1
6
2
7
3
8
4
9
5
10  
DIN RAIL  
35mm wide  
11 12 13 14 15  
16  
18 19 20  
17  
* Base does not come with the unit.  
Please order separately.  
MOUNTING REQUIREMENTS unit: mm [inch]  
2–M4 SCREW  
* Mounting requirements for base.  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 8/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
OUTPUT CODE 2: N.O. RELAY  
Channel 1  
+
RY  
RY  
Isolation  
1L2 OUTPUT  
1L1 OUTPUT  
COM1  
15  
14  
13  
18  
17  
16  
3
+
INPUT  
Low Drift  
Amplifier  
4
VOLTAGE  
INPUT  
CURRENT  
5
28Ω  
RY  
RY  
1L4 OUTPUT  
1L3 OUTPUT  
COM2  
Digital  
Computation  
Circuit  
Isolation  
RY  
RY  
Channel 2  
+
2L2 OUTPUT  
2L1 OUTPUT  
COM3  
12  
11  
6
8
9
+
INPUT  
VOLTAGE  
Low Drift  
Amplifier  
INPUT  
CURRENT  
10  
RY  
RY  
28Ω  
7
2L4 OUTPUT  
2L3 OUTPUT  
COM4  
2
1
CONFIGURATOR  
JACK  
Display  
Circuit  
+
19  
20  
POWER  
Front  
Button  
Base  
OUTPUT CODE 3: N.C. RELAY  
Channel 1  
1L2 OUTPUT  
15  
14  
13  
18  
17  
16  
1L1 OUTPUT  
COM1  
1L4 OUTPUT  
1L3 OUTPUT  
COM2  
Channel 2  
2L2 OUTPUT  
2L1 OUTPUT  
COM3  
12  
11  
6
7
2L4 OUTPUT  
2L3 OUTPUT  
COM4  
2
1
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 9/10  
https://www.m-system.co.jp/  
MODEL: M1EAXV-2  
OUTPUT CODE 5: SPDT RELAY  
Channel 1  
+
Isolation  
N.C.  
15  
14  
13  
18  
17  
16  
3
+
RY  
RY  
INPUT  
VOLTAGE  
Low Drift  
Amplifier  
N.O.  
1L1 OUTPUT  
1L2 OUTPUT  
4
INPUT  
CURRENT  
COM1  
N.C.  
5
28Ω  
N.O.  
Digital  
Computation  
Circuit  
COM2  
Isolation  
Channel 2  
+
N.C.  
12  
11  
6
RY  
RY  
8
9
N.O.  
2L1 OUTPUT  
+
Low Drift  
Amplifier  
INPUT  
VOLTAGE  
INPUT  
CURRENT  
COM3  
N.C.  
10  
28Ω  
7
2L2 OUTPUT  
2
N.O.  
CONFIGURATOR  
JACK  
COM4  
1
Display  
Circuit  
+
19  
20  
POWER  
Front  
Button  
Base  
• Relay Protection  
· AC Powered  
· DC Powered  
Inductive  
Load (Coil)  
Inductive  
Load (Coil)  
Diode, Varistor or  
CR Circuit  
Varistor or Spark  
Quenching Circuit  
LOAD  
LOAD  
U
Specifications are subject to change without notice.  
M1EAXV-2 SPECIFICATIONS  
ES-5995 Rev.2 Page 10/10  
https://www.m-system.co.jp/  

相关型号:

M1EAXV-2-5-R

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM

M1EAXV-2-5-R/Q

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM

M1EAXV1

Multi-output Super-mini Signal Conditioners with Display M1E-1 Series
MSYSTEM

M1EAXV2

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM

M1EN

CMOS ASIC encoder
ETC

M1EN-H

CMOS ASIC encoder
ETC

M1EN-S

CMOS ASIC encoder
ETC

M1EXM

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM

M1EXM-2

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM

M1EXM-2-M2

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM

M1EXM-2-M2/C01

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM

M1EXM-2-M2/C02

2 Channel Super-mini Signal Conditioners with Display M1E-2 Series
MSYSTEM