M2AS1-A443-M2 概述
Super-mini Signal Conditioners Mini-M Series
M2AS1-A443-M2 数据手册
通过下载M2AS1-A443-M2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: M2AS1
Super-mini Signal Conditioners Mini-M Series
[3] ON DELAY TIME
1: 0.05 second
2: 0.1 second
3: 0.2 second
4: 0.5 second
5: 1 second
DC ALARM
(thumbwheel switch adjustment; single SPDT output)
Functions & Features
• Provides a SPDT relay output at a preset DC input level
• Thumbwheel switch setpoint adjustments
• Adjustable deadband
6: 2 seconds
7: 5 seconds
8: 10 seconds
• Latching or non-latching output
• Relays energized or de-energized at tripped condition
[4] POWER ON DELAY TIME
1: 1 second
Typical Applications
• Annunciator
2: 2 seconds
• Various alarm applications
3: 3 seconds
23 (.91)
4: 4 seconds
[5] POWER INPUT
AC Power
76
(2.99)
4
3
4
1
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
124
(4.88)
R: 24 V DC
mm (inch)
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
MODEL: M2AS1–[1][2][3][4]–[5][6]
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
ORDERING INFORMATION
• Code number: M2AS1-[1][2][3][4]-[5][6]
Specify a code from below for each of [1] through [6].
(e.g. M2AS1-6111-M2/CE/Q)
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
[6] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE
• Specify the specification for option code /Q
(e.g. /C01/S01)
/CE: CE marking
Other Options
[1] INPUT
Current
blank: none
/Q: Option other than the above (specify the specification)
A: 4 – 20 mA DC (Input resistance 250 Ω)
Voltage
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
[2] ALARM OUTPUT
1: Hi (coil energized at alarm)
2: Hi (coil de-energized at alarm)
3: Lo (coil energized at alarm)
4: Lo (coil de-energized at alarm)
TERMINAL SCREW MATERIAL
/S01: Stainless steel
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
M2AS1 SPECIFICATIONS
ES-5064 Rev.12 Page 1/5
http://www.m-system.co.jp/
MODEL: M2AS1
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
INSTALLATION
Power Consumption
•AC:
Overrange input: -14 to +113.5 %
When the relay’s untripped point relative to the preset
alarm setpoint and deadband is out of this range, the relay
remains latched.
Approx. 3 VA at 100 V
Approx. 4 VA at 200 V
Approx. 5 VA at 264 V
•DC: Approx. 3 W
Setpoint adjustments: Thumbwheel switches (front);
0 – 99 % independently; 1 % increments
Deadband (hysteresis) : Thumbwheel switches (front);
1 – 99 % independently; 1 % increments
(latching output when set to 00)
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Installation Base (model: M2BS) is not adaptable.
Weight: 150 g (0.33 lb)
Front LED: Red light turns on when the coil is energized.
Reset input: Latched output reset with the front control
button or remotely via base socket terminals.
PERFORMANCE in percentage of span
Setpoint accuracy: ±0.5 %
INPUT SPECIFICATIONS
■ DC Current:
Deadband setpoint accuracy: ±0.5 %
Power ON timer: Rating ±0.5 sec. or 20 %, whichever is
greater.
Shunt resistor attached to the input terminals (0.5 W)
■ Reset Contact Input
Trip point repeatability: ±0.05 %
ON resistance: ≤ 1 kΩ
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Delay time (response time with 90 % setpoint for a step
input 0 – 100 %)
Detecting level: ≤ 0.43 V
OFF resistance: ≥ 50 kΩ
Detecting level: ≥ 4 V
Codes 1, 2: Rating ±25 msec.
Codes 3 to 8: Rating ±20 %
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
OUTPUT SPECIFICATIONS
■ Relay Contact:
120 V AC @5 A (cos ø = 1)
240 V AC @2.5 A (cos ø = 1)
30 V DC @5 A (resistive load)
Maximum switching voltage: 250 V AC or 120 V DC
Maximum switching power: 600 VA or 150 W
Minimum load: 5 V DC @10 mA
STANDARDS & APPROVALS
EU conformity:
EMC Directive
Mechanical life: 5 × 10 cycles
7
EMI EN 61000-6-4
EMS EN 61000-6-2
Alarm Trip Operation
Terminal No. in parentheses
Low Voltage Directive
• Alarm Output Code : 1, 4
EN 61010-1
(8–9)ON
Output
Measurement Category II (output)
Installation Category II (power)
Pollution Degree 2
(8–12)ON
Input
(%)
0
50
▲
100
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
Setpoint
• Alarm Output Code : 2, 3
(8–9)ON
Output
EN 50581
(8–12)ON
Input
(%)
0
▲
50
100
Setpoint
Trip Operation in Power Failure: Terminals 8 – 12 turn on.
M2AS1 SPECIFICATIONS
ES-5064 Rev.12 Page 2/5
http://www.m-system.co.jp/
MODEL: M2AS1
EXTERNAL VIEW
Output Setpoint Adj.
Deadband Adj.
9
9
9
9
Output Monitor LED
Reset Control
EXTERNAL DIMENSIONS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
4
1
5
8
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
12
9
8–M3
SCREW
14 13
21.5 (.85) 7.3 (.29)
86.7 (3.41)
116.7 (4.59)
15 (.59)
[4 (.16)]
23 (.91)
• When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm (inch)
INPUT RESISTOR
(model: REM2)
4
1
5
8
12
9
14 13
Input shunt resistor attached
for current input.
M2AS1 SPECIFICATIONS
ES-5064 Rev.12 Page 3/5
http://www.m-system.co.jp/
MODEL: M2AS1
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ Relay Protection
• AC Powered
Inductive
Load (Coil)
THUMBWHEEL
SWITCHES
Converter
Comparator
9 9
LOAD
12 N.C.
Low Drift
Amplifier
+
–
Ry
1
4
5
U
*
9
8
N.O.
COM
OUTPUT
INPUT
R
Varistor or CR Circuit
RESET
CONTROL
• DC Powered
RESET
Inductive
Load (Coil)
13
14
U(+)
V(–)
POWER
LOAD
THUMBWHEEL
SWITCHES
Converter
Base Socket
9 9
Diode, Varistor or
CR Circuit
*Input shunt resistor attached for current input.
FUNCTIONS
■ POWER ON DELAY TIME: The relay does not provide
a tripped condition for a duration of the preset Power
ON Delay Time (TDP) after the power supply is turned
on, even when the signal input is in an alarm range.
■ HIGH ALARM: When the signal input exceeds
the preset setpoint, the relay provides a tripped
condition.
• Hi Alarm
Input
Setpoint
• Power ON Delay Time (TDP) with Hi Alarm
Deadband
Input
TDP
Setpoint
Deadband
t
Bold Line : Alarm Tripped
Thin Line : Alarm Untripped
Power ON
t
■ LOW ALARM: When the signal input goes below
the preset setpoint, the relay provides a tripped
condition
Bold Line: Coil Energized
• Lo Alarm
Input
■ LATCHING OUTPUT: The relay does not return to an
untripped condition once the signal input goes across
the threshold, unless:
Deadband
Setpoint
(1) the Reset control button is pressed,
(2) the Reset input terminal is closed, or
(3) the power supply is removed.
t
Bold Line : Alarm Tripped
Thin Line : Alarm Untripped
• Latching Output with Hi Alarm
■ ON DELAY TIME: The relay status does not change
until after the preset ON Delay Time (TD) once the
signal input goes across the threshold.
Input
Setpoint
• ON Delay Time (TD) with Hi Alarm
Input
Reset Command
TD
T<TD
Setpoint
t
TD
t
Bold Line: Coil Energized
M2AS1 SPECIFICATIONS
ES-5064 Rev.12 Page 4/5
http://www.m-system.co.jp/
MODEL: M2AS1
Specifications are subject to change without notice.
M2AS1 SPECIFICATIONS
ES-5064 Rev.12 Page 5/5
http://www.m-system.co.jp/
M2AS1-A443-M2 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M2AS1-A443-M2/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-M2/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-M2/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-P | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-P/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-P/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-P/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-R | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-R/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2AS1-A443-R/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 |
M2AS1-A443-M2 相关文章
- 2024-11-08
- 22
- 2024-11-08
- 15
- 2024-11-08
- 16
- 2024-11-08
- 14