MODEL: M2BD
Super-mini Signal Conditioners Mini-M Series
RELATED PRODUCTS
• Programming Unit (model: PU-2x)
COMMUNICATION CONTROLLER
(DeviceNet)
GENERAL SPECIFICATIONS
Capacity: 4, 8 or 16 positions
Functions & Features
• Receiving up to 16 Mini-M modules
• Enabling interfacing analog I/Os to DeviceNet
• Power supplied through printed wiring on the base
Connection
DeviceNet: Euro type connector terminal (applicable
wire size: 0.2 to 2.5 mm , stripped length 7 mm)
2
I/O: M3 screw terminals (torque 0.8 N·m)
Power input: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel
Model
Model
Model
Model
Model
Model
Model
Model
Model
Model
Model
Model
Model
Model
Model
Model
Isolation: I/O to DeviceNet to power to FG1
Power indicator: Green LED turns on with power supplied.
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
SPAN
ZERO
ZERO
DeviceNet COMMUNICATION
Transmission cable: Approved for DeviceNet
Node address setting: DIP switch; 00 – 63
Baud rate setting: DIP switch
125 kbps (factory default), 250 kbps, 500 kbps
MS (Module Status) indicator: Bi-color (green/red) LED
indicates device status.
MODEL: M2BD–[1][2]-[3][4]
ORDERING INFORMATION
• Code number: M2BD-[1][2]-[3][4]
NS (Network Status) indicator: Bi-color (green/red)
LED indicates status of the communication link.
Specify a code from below for each of [1] through [4].
(e.g. M2BD-161-R/UL)
INPUT SPECIFICATIONS
Power input specification for each I/O modules must be the
same as that of the base.
Input modules: Mini-M series; output 1 – 5 V DC;
(Each input must be isolated by signal conditioners. Non-
isolated modules such as M2BW is not usable.)
■ Analog Input
[1] CAPACITY
04: 4 positions
Input range: See each I/O module spec.
Voltage at the field I/O terminals limited within 30 V DC for
UL.
08: 8 positions
16: 16 positions
Isolation: transformer (by Mini-M module)
A/D conversion output: 16-bit binary
[2] I/O TYPE
1: Input
Signal range 0 – 100 % is converted into hexadecimal 0000
– 1770 (0 – 6000). -15 to 0 % is represented by 2’s
complements.
2: Output
Overall range is represented by hexadecimal FC7C – 1AF4
(-900 – +6900), for -15 – +115 %.
[3] POWER INPUT
AC Power
Note: In the firmware version 3.00 or later, analog input
range 0 – 100% can be converted into hexadecimal 0000 –
2710 (0 – 10000).
K: 85 – 132 V AC
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
(CE or UL not available)
In addition, negative values of analog input range -15 to 0%
can be converted into signed absolute values.
Refer to the instruction manual for details.
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
OUTPUT SPECIFICATIONS
Output modules: Model M2VS; input 1 – 5 V DC
■ Analog Output
[4] OPTIONS
Standards & Approvals
blank: Without UL or CE
/UL: UL approval, CE marking
Output range: See model M2VS spec.
M2BD SPECIFICATIONS
ES-5002 Rev.10 Page 1/7
http://www.m-system.co.jp/
MODEL: M2BD
Isolation: Transformer
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
D/A conversion output: 16-bit binary
Signal range 0 – 100 % is converted into hexadecimal 0000
– 1770 (0 – 6000). -15 to 0 % is represented by 2’s
complements.
Measurement Category II (input)
Pollution Degree 2
Overall range is represented by hexadecimal FC7C – 1AF4 (-
900 – +6900), for -15 – +115 %.
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
Note: In the firmware version 3.00 or later, analog output
range 0 – 100% can be converted into hexadecimal 0000 –
2710 (0 – 10000).
EN 50581
Approval:
In addition, negative values of analog output range -15 to
0% can be converted into signed absolute values.
Refer to the instruction manual for details.
UL/C-UL nonincendive Class I, Division 2,
Groups A, B, C, and D
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
UL/C-UL general safety requirements
(UL 3111-1, CAN/CSA-C22.2 No.1010-1)
INSTALLATION
Power Consumption:
•AC:
approx. 6 VA without I/O module
approx. 30 VA with 4 modules (M2DY)
approx. 50 VA with 8 modules (M2DY)
approx. 90 VA with 16 modules (M2DY)
Current consumption:
•DC
approx. 0.25 A without I/O module
approx. 1 A with 4 modules (M2DY)
approx. 1.5 A with 8 modules (M2DY)
approx. 2.5 A with 16 modules (M2DY)
Supply voltage to network: 11 – 25 V DC supplied through
the network terminal block
Supply current to network: 60 mA max. @ 24 V
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Surface
Weight: Without I/O module
M2BD-04 1.2 kg (2.6 lb)
M2BD-08 1.5 kg (3.3 lb)
M2BD-16 2 kg (4.4 lb)
PERFORMANCE in percentage of span
A/D conversion: Accuracy of input module ±0.1%
D/A conversion: Accuracy of M2VS ±0.1 %
Permissible power failure duration: ≤ 10 msec.
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1000 V AC @1 minute (power to I/O
module to DeviceNet module to FG1)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
M2BD SPECIFICATIONS
ES-5002 Rev.10 Page 2/7
http://www.m-system.co.jp/
MODEL: M2BD
COMM. MODULE FRONT PANEL
PU-2x Modular Jack
Power LED
MS Indicator LED
NS Indicator LED
PWR
MS
NS
NA0
NA1
NA2
NA3
NA4
NA5
DR0
DR1
Node
Address
Setting
Baud Rate
Setting
Euro Type Connector Terminal
for DeviceNet
ON
Refer to the instruction manual for detailed procedures.
EXTERNAL DIMENSIONS unit: mm (inch)
■ M2BD-041 (INPUT BASE)
210 (8.27)
190 (7.48)
170 (6.69)
1
2
3
4
5 8 5 8 5 8 5 8
1 4 1 4 1 4 1 4
FG1
13 14
CH1
CH4
2–M3 POWER
TERMINALS
**
CT PROTECTOR (CTM2)
6 (.24)
16–M3 INPUT TERMINALS
* 165 (6.50) required for pneumatic tubing for M2PV.
** Attached to M2CA and M2CE.
M2BD SPECIFICATIONS
ES-5002 Rev.10 Page 3/7
http://www.m-system.co.jp/
MODEL: M2BD
■ M2BD-042 (OUTPUT BASE)
210 (8.27)
190 (7.48)
170 (6.69)
6 (.24)
8–M3 OUTPUT
TERMINALS
CH1 CH2 CH3 CH4
9
12
9
12
9
12
9 12
1
2
3
4
FG1
13 14
2–M3 POWER
TERMINALS
■ M2BD-081 (INPUT BASE)
300 (11.81)
280 (11.02)
260 (10.24)
1
2
3
4
5
6
7
8
5 8 5 8 5 8 5 8 5 8 5 8 5 8 5 8
FG1
1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 13 14
CH1 CH7 CH8
2–M3 POWER
TERMINALS
6 (.24)
**
CT PROTECTOR (CTM2)
32–M3 INPUT TERMINALS
* 165 (6.50) required for pneumatic tubing for M2PV.
** Attached to M2CA and M2CE.
M2BD SPECIFICATIONS
ES-5002 Rev.10 Page 4/7
http://www.m-system.co.jp/
MODEL: M2BD
■ M2BD-082 (OUTPUT BASE)
300 (11.81)
280 (11.02)
260 (10.24)
6 (.24)
16–M3 OUTPUT
TERMINALS
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8
9
12
9
12
9
12
9
12
9
12
9
12
9
12
9
12
1
2
3
4
5
6
7
8
FG1
13 14
2–M3 POWER
TERMINALS
■ M2BD-161 (INPUT BASE)
480 (18.90)
460 (18.11)
440 (17.32)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
5 8 5 8 5 8 5 8 5 8 5 8
FG1
5 8 5 8 5 8 5 8 5 8
1 4 1 4 1 4 1 4 1 4
5 8 5 8 5 8 5 8 5 8
1 4 1 4 1 4 1 4 1 4
1 4 1 4 1 4 1 4 1 4 1 4 13 14
CH11 CH16
CH1
CH5
CH6
CH10
2–M3 POWER
TERMINALS
**
CT PROTECTOR (CTM2)
6 (.24)
64–M3 INPUT TERMINALS
* 165 (6.50) required for pneumatic tubing for M2PV.
** Attached to M2CA and M2CE.
M2BD SPECIFICATIONS
ES-5002 Rev.10 Page 5/7
http://www.m-system.co.jp/
MODEL: M2BD
■ M2BD-162 (OUTPUT BASE)
480 (18.90)
460 (18.11)
440 (17.32)
6 (.24)
32–M3 OUTPUT TERMINALS
CH1 CH2 CH3 CH4 CH5
12 12 12 12 12
CH6 CH7 CH8 CH9 CH10
12 12 12 12 12
CH11 CH12 CH13 CH14 CH15 CH16
9
9
9
9
9
9
9
9
9
9
9
12
9
12
9
12
9
12
9
12
9
12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
FG1
13 14
2–M3 POWER
TERMINALS
MOUNTING REQUIREMENTS unit: mm (inch)
■ M2BD-04
190 (7.48)
4–M5 SCREW
■ M2BD-08
280 (11.02)
4–M5 SCREW
■ M2BD-16
460 (18.11)
4–M5 SCREW
M2BD SPECIFICATIONS
ES-5002 Rev.10 Page 6/7
http://www.m-system.co.jp/
MODEL: M2BD
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG1 terminal to ground.
Caution: FG1 terminal is NOT a protective conductor terminal.
■ INPUT BASE
■ OUTPUT BASE
COMMUNICATION MODULE
INDCATOR
I/O MODULES
1
ISOLATION
4
9
Ch.1
INPUT
5
Ch.1
OUTPUT
DIP SW
LED
V+
12
CAN_H
Drain
CAN_L
V–
To Other
DeviceNet
Devices
8
Communication
CPU
1
ISOLATION
4
9
Ch.2
INPUT
Ch.2
OUTPUT
A / D
or
D / A
Conv.
I / O
CPU
5
8
12
MODULAR JACK
PU-2x
SERIAL
TRANSMISSION
LINE
1
4
5
8
ISOLATION
9
Ch.16
INPUT
Ch.16
OUTPUT
12
13
14
U(+)
V(–)
POWER
FG1
Specifications are subject to change without notice.
M2BD SPECIFICATIONS
ES-5002 Rev.10 Page 7/7