M2PHS2H-B3-M/N

更新时间:2024-10-29 22:29:35
品牌:MSYSTEM
描述:Super-mini Signal Conditioners Mini-M Series

M2PHS2H-B3-M/N 概述

Super-mini Signal Conditioners Mini-M Series

M2PHS2H-B3-M/N 数据手册

通过下载M2PHS2H-B3-M/N数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: M2PHS2  
F: 0 – 10 mA DC (Input resistance 100 Ω)  
Super-mini Signal Conditioners Mini-M Series  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
J: 0 – 10 μA DC (Input resistance 1000 Ω)  
K: 0 – 100 μA DC (Input resistance 1000 Ω)  
GW: -1 – +1 mA DC (Input resistance 1000 Ω)  
FW: -10 – +10 mA DC (Input resistance 100 Ω)  
Z: Specify current (See INPUT SPECIFICATIONS)  
Voltage  
PEAK HOLD  
(with simple loop test output)  
Functions & Features  
• Track mode: the output follows proportionally to the input  
• Peak-hold mode: responds only to an increasing signal,  
holding the maximum value until a higher signal or a  
command to reset is received  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
15: 0 – 50 mV DC (Input resistance 10 kΩ min.)  
16: 0 – 60 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)  
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
• Valley hold and peak-to-peak mode selectable  
• Simple loop test output (0, 50, 100%)  
Typical Applications  
• Monitoring peak power consumption  
• Monitoring the highest or lowest temperature  
23 (.91)  
Model  
76  
(2.99)  
[3] OUTPUT  
Current  
ZERO  
SPAN  
124  
(4.88)  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
mm (inch)  
MODEL: M2PHS2[1]-[2][3]-[4][5]  
ORDERING INFORMATION  
• Code number: M2PHS2[1]-[2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. M2PHS2H-6A-M2/CE/Q)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Special input and output ranges (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[1] HOLD FUNCTION  
H: Peak hold  
L: Valley hold  
W: Peak-to-peak hold  
[4] POWER INPUT  
AC Power  
[2] INPUT  
Current  
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
A1: 4 – 20 mA DC (Input resistance 50 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
E: 0 – 16 mA DC (Input resistance 62.5 Ω)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
DC Power  
R: 24 V DC  
M2PHS2 SPECIFICATIONS  
ES-5105 Rev.8 Page 1/5  
http://www.m-system.co.jp/  
MODEL: M2PHS2  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R2: 11 – 27 V DC  
DC Voltage: -300 – +300 V DC  
Minimum span: 3 mV  
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
P: 110 V DC  
Offset: Max. 1.5 times span  
Input resistance  
Span 3 – 10 mV : ≥ 10 kΩ  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Span ≥ 1 V : ≥ 1 MΩ  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
[5] OPTIONS (multiple selections)  
Standards & Approvals (must be specified)  
/N: Without CE  
Hold Control  
Contact rating: 5 V @ 1 mA  
Detection levels: ≤ 1.25 kΩ / 1 V at ON  
≥ 20 kΩ / 4 V at OFF  
/CE: CE marking  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
/C02: Polyurethane coating  
/C03: Rubber coating  
Offset: Max. 1.5 times span  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V  
INSTALLATION  
Power Consumption  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
AC:  
Connection: M3 screw terminals (torque 0.8 N·m)  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Approx. 3 VA at 100 V  
Approx. 4 VA at 200 V  
Approx. 5 VA at 264 V  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
DIP switch setting: Selecting output options  
• Output Function (normal output, or loop test output of 0%,  
50% and 100%.)  
DC: Approx. 3 W  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 150 g (0.33 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 %  
• Output Limit (ON, OFF)  
Hold control: Contact logic selectable by the DIP switch  
setting  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Status indicator LED 1: Green LED; indicates the  
transmitter’s function mode (Refer to the instruction  
manual.)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
Status indicator LED 2: Orange LED; indicates the  
transmitter’s function mode (Refer to the instruction  
manual.)  
STANDARDS & APPROVALS  
EU conformity:  
INPUT SPECIFICATIONS  
DC Current:  
EMC Directive  
EMI EN 61000-6-4  
Shunt resistor attached to the input terminals (0.5 W)  
Specify input resistance value for code Z.  
EMS EN 61000-6-2  
Low Voltage Directive  
M2PHS2 SPECIFICATIONS  
ES-5105 Rev.8 Page 2/5  
http://www.m-system.co.jp/  
MODEL: M2PHS2  
EN 61010-1  
Measurement Category II (input)  
Installation Category II (power)  
Pollution Degree 2  
Input or output to power: Reinforced insulation (300 V)  
Input to output: Basic insulation (300 V)  
RoHS Directive  
EN 50581  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
Status Indicator LED2  
Output Function  
Setting  
SW1  
Status Indicator LED1  
1 2 3 4  
ON  
OFF  
Zero Adj.  
Span Adj.  
Refer to the instruction manual for detailed procedures.  
EXTERNAL DIMENSIONS unit: mm (inch)  
6 (.23)  
DIN RAIL  
35mm wide  
4
1
5
8
2–4.2x5  
(.17x.20)  
MTG HOLE  
6 (.24) deep  
12  
9
8–M3  
SCREW  
14 13  
21.5 (.85) 10 (.39)  
84 (3.31)  
114 (4.49)  
15 (.59)  
[4 (.16)]  
23 (.91)  
• When mounting, no extra space is needed between units.  
M2PHS2 SPECIFICATIONS  
ES-5105 Rev.8 Page 3/5  
http://www.m-system.co.jp/  
MODEL: M2PHS2  
TERMINAL ASSIGNMENTS unit: mm (inch)  
INPUT RESISTOR  
(model: REM2)  
4
1
5
8
12  
9
14 13  
Input shunt resistor attached  
for current input.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
STATUS  
Z
S
Isolation  
Low Drift  
Amplifier  
Output  
Driver  
Hold  
+
1
4
9
+
*
INPUT  
R
OUTPUT  
12  
13  
14  
+5V  
5kΩ  
DIP SWITCH  
U(+)  
POWER  
V(–)  
5
8
HOLD CONTROL  
Base Socket  
*Input shunt resistor attached for current input.  
M2PHS2 SPECIFICATIONS  
ES-5105 Rev.8 Page 4/5  
http://www.m-system.co.jp/  
MODEL: M2PHS2  
HOLD MODES  
■ PEAK HOLD MODE  
The transmitter output responds only to an increasing  
signal, holding the maximum value until a higher signal or a  
command to reset is received.  
■ VALLEY HOLD MODE  
The transmitter output responds only to a decreasing signal,  
holding the minimum value until a lower signal or a  
command to reset is received.  
■ PEAK-TO-PEAK HOLD MODE  
The transmitter output responds only when the input signal  
goes over the previously monitored maximum value or goes  
below the previously monitored minimum value.  
The output is proportional to the peak-to-peak value,  
absolute difference between the maximum and the  
minimum values.  
• Peak-to-Peak Hold Mode  
INPUT  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
0%  
t
OUTPUT  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
0%  
t
HOLD  
RESET  
Specifications are subject to change without notice.  
M2PHS2 SPECIFICATIONS  
ES-5105 Rev.8 Page 5/5  
http://www.m-system.co.jp/  

M2PHS2H-B3-M/N 相关器件

型号 制造商 描述 价格 文档
M2PHS2H-B3-M/Q MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-M2 MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-M2/CE MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-M2/N MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-M2/Q MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-P MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-P/CE MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-P/N MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-P/Q MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PHS2H-B3-R MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格

M2PHS2H-B3-M/N 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8