M2PHS2H-B3-M/N 概述
Super-mini Signal Conditioners Mini-M Series
M2PHS2H-B3-M/N 数据手册
通过下载M2PHS2H-B3-M/N数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: M2PHS2
F: 0 – 10 mA DC (Input resistance 100 Ω)
Super-mini Signal Conditioners Mini-M Series
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
J: 0 – 10 μA DC (Input resistance 1000 Ω)
K: 0 – 100 μA DC (Input resistance 1000 Ω)
GW: -1 – +1 mA DC (Input resistance 1000 Ω)
FW: -10 – +10 mA DC (Input resistance 100 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
PEAK HOLD
(with simple loop test output)
Functions & Features
• Track mode: the output follows proportionally to the input
• Peak-hold mode: responds only to an increasing signal,
holding the maximum value until a higher signal or a
command to reset is received
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)
15: 0 – 50 mV DC (Input resistance 10 kΩ min.)
16: 0 – 60 mV DC (Input resistance 10 kΩ min.)
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
• Valley hold and peak-to-peak mode selectable
• Simple loop test output (0, 50, 100%)
Typical Applications
• Monitoring peak power consumption
• Monitoring the highest or lowest temperature
23 (.91)
Model
76
(2.99)
[3] OUTPUT
Current
ZERO
SPAN
124
(4.88)
A: 4 – 20 mA DC (Load resistance 750 Ω max.)
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)
D: 0 – 20 mA DC (Load resistance 750 Ω max.)
E: 0 – 16 mA DC (Load resistance 900 Ω max.)
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
mm (inch)
MODEL: M2PHS2[1]-[2][3]-[4][5]
ORDERING INFORMATION
• Code number: M2PHS2[1]-[2][3]-[4][5]
Specify a code from below for each of [1] through [5].
(e.g. M2PHS2H-6A-M2/CE/Q)
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 1000 Ω min.)
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
• Special input and output ranges (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
[1] HOLD FUNCTION
H: Peak hold
L: Valley hold
W: Peak-to-peak hold
[4] POWER INPUT
AC Power
[2] INPUT
Current
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
A: 4 – 20 mA DC (Input resistance 250 Ω)
A1: 4 – 20 mA DC (Input resistance 50 Ω)
B: 2 – 10 mA DC (Input resistance 500 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 50 Ω)
E: 0 – 16 mA DC (Input resistance 62.5 Ω)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
R: 24 V DC
M2PHS2 SPECIFICATIONS
ES-5105 Rev.8 Page 1/5
http://www.m-system.co.jp/
MODEL: M2PHS2
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
■ DC Voltage: -300 – +300 V DC
Minimum span: 3 mV
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
Offset: Max. 1.5 times span
Input resistance
Span 3 – 10 mV : ≥ 10 kΩ
Span 10 – 100 mV : ≥ 10 kΩ
Span 0.1 – 1 V : ≥ 100 kΩ
Span ≥ 1 V : ≥ 1 MΩ
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
[5] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE
■ Hold Control
Contact rating: 5 V @ 1 mA
Detection levels: ≤ 1.25 kΩ / 1 V at ON
≥ 20 kΩ / 4 V at OFF
/CE: CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
Minimum span: 1 mA
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Offset: Max. 1.5 times span
Load resistance: Output drive 15 V max.
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
/C02: Polyurethane coating
/C03: Rubber coating
Offset: Max. 1.5 times span
TERMINAL SCREW MATERIAL
/S01: Stainless steel
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
INSTALLATION
Power Consumption
GENERAL SPECIFICATIONS
Construction: Plug-in
•AC:
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
Approx. 3 VA at 100 V
Approx. 4 VA at 200 V
Approx. 5 VA at 264 V
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
DIP switch setting: Selecting output options
• Output Function (normal output, or loop test output of 0%,
50% and 100%.)
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)
PERFORMANCE in percentage of span
Accuracy: ±0.1 %
• Output Limit (ON, OFF)
Hold control: Contact logic selectable by the DIP switch
setting
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: ≤ 0.5 sec. (0 – 90 %)
Status indicator LED 1: Green LED; indicates the
transmitter’s function mode (Refer to the instruction
manual.)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
Status indicator LED 2: Orange LED; indicates the
transmitter’s function mode (Refer to the instruction
manual.)
STANDARDS & APPROVALS
EU conformity:
INPUT SPECIFICATIONS
■ DC Current:
EMC Directive
EMI EN 61000-6-4
Shunt resistor attached to the input terminals (0.5 W)
Specify input resistance value for code Z.
EMS EN 61000-6-2
Low Voltage Directive
M2PHS2 SPECIFICATIONS
ES-5105 Rev.8 Page 2/5
http://www.m-system.co.jp/
MODEL: M2PHS2
EN 61010-1
Measurement Category II (input)
Installation Category II (power)
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
EN 50581
EXTERNAL VIEW
■ FRONT VIEW
■ SIDE VIEW
Status Indicator LED2
Output Function
Setting
SW1
Status Indicator LED1
1 2 3 4
ON
OFF
Zero Adj.
Span Adj.
Refer to the instruction manual for detailed procedures.
EXTERNAL DIMENSIONS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
4
1
5
8
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
12
9
8–M3
SCREW
14 13
21.5 (.85) 10 (.39)
84 (3.31)
114 (4.49)
15 (.59)
[4 (.16)]
23 (.91)
• When mounting, no extra space is needed between units.
M2PHS2 SPECIFICATIONS
ES-5105 Rev.8 Page 3/5
http://www.m-system.co.jp/
MODEL: M2PHS2
TERMINAL ASSIGNMENTS unit: mm (inch)
INPUT RESISTOR
(model: REM2)
4
1
5
8
12
9
14 13
Input shunt resistor attached
for current input.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
STATUS
Z
S
Isolation
Low Drift
Amplifier
Output
Driver
Hold
+
–
1
4
9
+
*
INPUT
R
OUTPUT
–
12
13
14
+5V
5kΩ
DIP SWITCH
U(+)
POWER
V(–)
5
8
HOLD CONTROL
Base Socket
*Input shunt resistor attached for current input.
M2PHS2 SPECIFICATIONS
ES-5105 Rev.8 Page 4/5
http://www.m-system.co.jp/
MODEL: M2PHS2
HOLD MODES
■ PEAK HOLD MODE
The transmitter output responds only to an increasing
signal, holding the maximum value until a higher signal or a
command to reset is received.
■ VALLEY HOLD MODE
The transmitter output responds only to a decreasing signal,
holding the minimum value until a lower signal or a
command to reset is received.
■ PEAK-TO-PEAK HOLD MODE
The transmitter output responds only when the input signal
goes over the previously monitored maximum value or goes
below the previously monitored minimum value.
The output is proportional to the peak-to-peak value,
absolute difference between the maximum and the
minimum values.
• Peak-to-Peak Hold Mode
INPUT
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
t
OUTPUT
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
t
HOLD
RESET
Specifications are subject to change without notice.
M2PHS2 SPECIFICATIONS
ES-5105 Rev.8 Page 5/5
http://www.m-system.co.jp/
M2PHS2H-B3-M/N 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M2PHS2H-B3-M/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-M2 | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-M2/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-M2/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-M2/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-P | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-P/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-P/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-P/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PHS2H-B3-R | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 |
M2PHS2H-B3-M/N 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8