Super-mini Signal Conditioners Mini-M Series
[3] OUTPUT LOGIC
N: The same as the input
R: Inverted
PULSE ISOLATOR
Functions & Features
• Galvanically isolates pulse rate signals
• Input frequency = output frequency
• Various outputs (open collector, voltage pulses and dry
contact AC/DC switch)
[4] POWER INPUT
AC Power
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
Typical Applications
• Isolating field pulse signals in order to reduce noises
• Changing e.g. dry contact signal to e.g. 5 V signals
(‘/UL’ is not selectable for ‘Standards & Approvals’ code.)
DC Power
23 (.91)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
Model
76
(2.99)
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(‘/UL’ is not selectable for ‘Standards & Approvals’ code.)
124
(4.88)
mm (inch)
[5] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE or UL
MODEL: M2PP–[1][2][3]–[4][5]
/CE: CE marking
ORDERING INFORMATION
• Code number: M2PP-[1][2][3]-[4][5]
Specify a code from below for each of [1] through [5].
(e.g. M2PP-33N-M2/CE/Q)
/UL: UL approval, CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)
• Specify the specification for option code /Q
(e.g. /C01/S01)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
[1] INPUT
1: Mechanical contact (max. 30 Hz)
2: Open collector (max. 10 kHz)
3: Voltage pulse (max. 10 kHz)
9: Clamp-on pulse sensor CLSP
(‘/UL’ is not selectable for ‘Standards & Approvals’ code.)
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
TERMINAL SCREW MATERIAL
/S01: Stainless steel (UL not available)
RELATED PRODUCTS
• Clamp-on pulse sensor (model: CLSP)
[2] OUTPUT
1: Low frequency open collector (max. 30 Hz)
2: High frequency open collector (max. 10 kHz)
3: 5 V pulse (max. 10 kHz)
4: 12 V pulse (max. 10 kHz)
5: 24 V pulse (max. 10 kHz)
7: Dry contact AC/DC switch (max. frequency 30 Hz)
(‘/UL’ is not selectable for ‘Standards & Approvals’ code.)
M2PP SPECIFICATIONS
ES-5061 Rev.22 Page 1/4
http://www.m-system.co.jp/
MODEL: M2PP
GENERAL SPECIFICATIONS
Construction: Plug-in
OUTPUT SPECIFICATIONS
■ Low Frequency Open Collector:
50 V DC @100 mA (resistive load)
Maximum frequency: 30 Hz
Timer: Limits ≥ 75 msec. within 75 ±25 msec.
ON time for output logic non-inverted
OFF time for output logic inverted
Saturation voltage: 0.5 V DC
■ High Frequency Open Collector:
50 V DC @100 mA (resistive load)
Maximum frequency: 10 kHz
Saturation voltage: 0.5 V DC
■ Voltage Pulse
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Frequency range: Input and output are the same.
Chattering protection: Filter provided for mechanical
contact input
Input pulse sensing: DC coupled
INPUT SPECIFICATIONS
Excitation: 12 V DC @30 mA; shortcircuit protection
■ Open Collector
Maximum frequency: 10 kHz
High level: Rating (5, 12 or 24 V) ±10 %
Low level: ≤ 0.5V
Maximum frequency: 10 kHz
Load resistance:
Pulse width time requirement: 10 μsec. min. for ON and OFF
Sensing: Approx. 12 V DC @3 mA
ON/OFF level: ≤ 600 Ω / 1.8 V for ON, ≥ 100 kΩ / 3.5 V for
OFF
≥ 250 Ω for 5 V
≥ 600 Ω for 12 V
≥ 1200 Ω for 24 V
■ Dry Contact AC/DC Switch
132 V AC @200 mA (cos ø = 1)
30 V DC @200 mA (resistive load)
Maximum frequency: 30 Hz
Timer: Limits within 75 ±25 msec.
for wider than 75 msec. pulses
ON time for output logic non-inverted
OFF time for output logic inverted
Saturation voltage: 3 V DC
■ Mechanical Contact
Maximum frequency: 30 Hz
Pulse width time requirement: 10 msec. min. for ON and
OFF
Sensing: Approx. 12 V DC @3 mA
ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2.5 V for
OFF
■ Voltage Pulse
Maximum frequency: 10 kHz
Pulse width time requirement: 10 μsec. min. for high and
low levels
INSTALLATION
Waveforms: Square or sine
Power Consumption
Hi/Lo level: 2 – 50 V for high level; ≤1 V for low level
Input impedance: 10 kΩ min.
•AC:
Approx. 3 VA at 100 V
■ Clamp-on Pulse Sensor CLSP
Maximum frequency: 50 000 pulses/hour
ON/OFF level: ≤ 400 Ω / 1.3 V for ON, ≥ 200 kΩ / 12 V for
OFF
Approx. 4 VA at 200 V
Approx. 5 VA at 264 V
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)
PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
M2PP SPECIFICATIONS
ES-5061 Rev.22 Page 2/4
http://www.m-system.co.jp/
MODEL: M2PP
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Measurement Category II (output)
Installation Category II (power)
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
EN 50581
Approval:
UL/C-UL nonincendive Class I, Division 2,
Groups A, B, C, and D
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
UL/C-UL general safety requirements
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)
OUTPUT LOGIC
VOLTAGE PULSE
OUTPUT
OPEN COLLECTOR
DRY CONTACT AC/DC SWITCH
INPUT TYPE
PULSE LOGIC
Non Inverted
INPUT
H
H
OFF
L
L
ON
Voltage Pulse
H
H
OFF
Inverted
Non Inverted
Inverted
L
L
ON
OFF
H
OFF
Mechanical Contact
Open Collector
Clamp-on Pulse
Sensor CLSP
ON
L
ON
OFF
H
OFF
ON
L
ON
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
4
1
5
8
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
12
9
8–M3
SCREW
14 13
21.5 (.85) 10 (.39)
84 (3.31)
114 (4.49)
15 (.59)
[4 (.16)]
23 (.91)
• When mounting, no extra space is needed between units.
M2PP SPECIFICATIONS
ES-5061 Rev.22 Page 3/4
http://www.m-system.co.jp/
MODEL: M2PP
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Isolation
*
Waveform
Shaper
Output
Driver
+
–
1
4
5
8
9
+
Timer
INPUT
OUTPUT
POWER
12
13
14
–
SENSOR EXCITATION
+
12V Supply
U(+)
V(–)
Base Socket
* Low freq. open collector and dry contact AC/DC switch output only.
Input Connection Examples
Output Connection Examples
■ Mechanical Contact, Open Collector
or Clamp-on Pulse Sensor CLSP
■ Open Collector
■ Dry Contact AC/DC Switch
• AC Powered
Relay or
Counter Coil
+
–
–
+
+
–
+
1
4
5
+
–
+
–
9
9
Varistor or Spark
Quenching Circuit
LOAD
12
12
+12V
PWR
U
4kΩ
■ Voltage Pulse
• DC Powered
Relay or
Counter Coil
■ Voltage Pulse
9
+
–
+
–
9
Spark Quenching Diode
LOAD
12
+
–
–
+
+
–
+
1
4
5
12
+12V
PWR
Specifications are subject to change without notice.
M2PP SPECIFICATIONS
ES-5061 Rev.22 Page 4/4
http://www.m-system.co.jp/
M2PP-17R-M/CE 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M2PP-17R-M/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-M/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-M/UL | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-M2 | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-M2/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-M2/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-M2/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-M2/UL | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-P | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2PP-17R-P/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 |
M2PP-17R-M/CE 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8