M2PV-C1S0-M

更新时间:2024-10-29 22:31:47
品牌:MSYSTEM
描述:Super-mini Signal Conditioners Mini-M Series

M2PV-C1S0-M 概述

Super-mini Signal Conditioners Mini-M Series

M2PV-C1S0-M 数据手册

通过下载M2PV-C1S0-M数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: M2PV  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Super-mini Signal Conditioners Mini-M Series  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
P/I TRANSDUCER  
Functions & Features  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Converts a standard pneumatic signal into a  
proportional DC output  
Typical Applications  
• Converting a pneumatic system into a 4 – 20 mA for  
indicating and controlling in DCS system  
[3] POWER INPUT  
23 (.91)  
AC Power  
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
Model  
76  
(2.99)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
ZERO  
SPAN  
126  
(4.96)  
(90 – 264 V for UL)  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R2: 11 – 27 V DC  
MODEL: M2PV–C[1][2]–[3][4]  
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
P: 110 V DC  
ORDERING INFORMATION  
• Code number: M2PV-C[1][2]-[3][4]  
Specify a code from below for each [1] through [4].  
(e.g. M2PV-C2SA-M2/CE/Q)  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
(110 V ±10 % for UL)  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] OPTIONS (multiple selections)  
Standards & Approvals (must be specified)  
/N: Without CE or UL  
PNEUMATIC CONNECTION  
/CE: CE marking  
C: 6 mm dia. (.24”)  
/UL: UL approval, CE marking  
Other Options  
blank: none  
[1] INPUT  
/Q: Option other than the above (specify the specification)  
1S: 19.6 – 98.1 kPa  
2S: 20 – 100 kPa  
3S: 20.7 – 103.4 kPa  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
1: 0.2 – 1.0 kgf/cm  
2: 0.2 – 1.0 bar  
3: 3 – 15 psig  
2
/C02: Polyurethane coating  
/C03: Rubber coating (UL not available)  
TERMINAL SCREW MATERIAL  
[2] OUTPUT  
Current  
/S01: Stainless steel (UL not available)  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
M2PV SPECIFICATIONS  
ES-5044 Rev.16 Page 1/3  
http://www.m-system.co.jp/  
MODEL: M2PV  
Dielectric strength: 2000 V AC @ 1 minute (output to power  
to ground)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection  
Output & power input: M3 screw terminals (torque 0.8  
N·m)  
STANDARDS & APPROVALS  
EU conformity:  
Pneumatic: 6 mm dia (.24”) tube  
Screw terminal: Chromated steel (standard) or stainless  
steel  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Housing material: Flame-resistant resin (black)  
Isolation: Output to power  
Low Voltage Directive  
EN 61010-1  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Installation Category II  
Pollution Degree 2  
Output to power: Reinforced insulation (300 V)  
RoHS Directive  
EN 50581  
INPUT SPECIFICATIONS  
Input  
Approval:  
UL/C-UL nonincendive Class I, Division 2,  
Groups A, B, C, and D  
19.6 – 98.1 kPa, 0.2 – 1.0 kgf/cm  
2
20 – 100 kPa, 0.2 – 1.0 bar  
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)  
UL/C-UL general safety requirements  
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)  
20.7 – 103.4 kPa, 3 – 15 psig  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: 0 – 12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max.; at ≥ 1 V  
INSTALLATION  
Power Consumption  
AC:  
Approx. 3 VA at 100 V  
Approx. 4 VA at 200 V  
Approx. 5 VA at 264 V  
DC: Approx. 3 W  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 150 g (0.33 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.3 %  
Temp. coefficient: ±0.03 %/°C (±0.02 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Permissible overrange: 196 kPa (2.0 kgf/cm2, 1.96 bar, 28  
psig)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
M2PV SPECIFICATIONS  
ES-5044 Rev.16 Page 2/3  
http://www.m-system.co.jp/  
MODEL: M2PV  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
PNEUMATIC COUPLER  
(tube size 6 [.24] dia.)  
6 (.23)  
DIN RAIL  
35mm wide  
4
1
5
8
2–4.2x5  
(.17x.20)  
MTG HOLE  
6 (.24) deep  
12  
9
8–M3  
SCREW  
14 13  
approx.  
21.5 (.85)  
84 (3.31)  
114 (4.49)  
15 (.59)  
12 (.47)  
[4 (.16)]  
23 (.91)  
• When mounting, no extra space is needed between units.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Z
S
Semiconductor  
Pressure Sensor  
Low Drift  
Amplifier  
Output  
Driver  
9
+
INPUT  
OUTPUT  
POWER  
12  
13  
14  
U(+)  
V(–)  
CONSTANT  
CURRENT  
Base Socket  
Specifications are subject to change without notice.  
M2PV SPECIFICATIONS  
ES-5044 Rev.16 Page 3/3  
http://www.m-system.co.jp/  

M2PV-C1S0-M 相关器件

型号 制造商 描述 价格 文档
M2PV-C1S0-M/CE MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M/N MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M/Q MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M/UL MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M2 MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M2/CE MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M2/N MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M2/Q MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-M2/UL MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格
M2PV-C1S0-P MSYSTEM Super-mini Signal Conditioners Mini-M Series 获取价格

M2PV-C1S0-M 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8