M2RTS-R-C3-R/N 概述
Super-mini Signal Conditioners Mini-M Series
M2RTS-R-C3-R/N 数据手册
通过下载M2RTS-R-C3-R/N数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: M2RTS
Super-mini Signal Conditioners Mini-M Series
[2] INPUT
Current
A: 4 – 20 mA DC (Input resistance 250 Ω)
A1: 4 – 20 mA DC (Input resistance 50 Ω)
B: 2 – 10 mA DC (Input resistance 500 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 50 Ω)
E: 0 – 16 mA DC (Input resistance 62.5 Ω)
F: 0 – 10 mA DC (Input resistance 100 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
K: 0 – 100 μA DC (Input resistance 1000 Ω)
GW: -1 – +1 mA DC (Input resistance 1000 Ω)
FW: -10 – +10 mA DC (Input resistance 100 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
RATIO/BIAS TRANSMITTER
(input bias)
Functions & Features
• Provides precise matching of DC control signals to final
control elements in open- or closed-loop systems
• Easy ratio/bias setting with the front digital display
• Ratio adjustable from 0.1 to 4.00 or from -0.1 to -4.00;
Bias adjustable to ±100 %
Typical Applications
• Ratio control for air/fuel flows or for two flows
• Gain calculation for manipulated variable from a controller
• Large scale signal span adjustment
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
23 (.91)
M
od
el
76
(2.99)
124
(4.88)
mm (inch)
[3] OUTPUT
Current
A: 4 – 20 mA DC (Load resistance 750 Ω max.)
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)
D: 0 – 20 mA DC (Load resistance 750 Ω max.)
E: 0 – 16 mA DC (Load resistance 900 Ω max.)
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
MODEL: M2RTS-[1]-[2][3]-[4][5]
ORDERING INFORMATION
• Code number: M2RTS-[1]-[2][3]-[4][5]
Specify a code from below for each [1] through [5].
(e.g. M2RTS-S-6A-M2/CE/Q)
• Special input and output ranges (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 1000 Ω min.)
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
[1] OUTPUT CHARACTERISTICS
S: Proportional; ratio 0.1 to 4.00
R: Inverted; ratio -0.1 to -4.00
M2RTS SPECIFICATIONS
ES-5096 Rev.11 Page 1/5
http://www.m-system.co.jp/
MODEL: M2RTS
Linear characteristics
[4] POWER INPUT
AC Power
0.1 to 4.00 (proportional)
-0.1 to -4.00 (inverted)
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
X
i
: Input (approx. -10 to +120 %)
47 – 66 Hz)
B : Bias (-100 to +100 %)
(90 – 264 V for UL)
■ INDICATORS
DC Power
Ratio/bias digital display: Red LED; 6.4 mm (.25”) 7
segment, 3 digits
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
Polarity indicator: Dual color (red/green) LED; Red with a
positive set value; Green with a negative set value.
Power saving mode: Indicators turn off if the switches are
untouched for 1 minute.
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)
INPUT SPECIFICATIONS
■ DC Current:
Shunt resistor attached to the input terminals (0.5 W)
Specify input resistance value for code Z.
■ DC Voltage: -30 – +30 V DC
Minimum span: 100 mV
[5] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE or UL
/CE: CE marking
Offset: Max. 1.5 times span
•Input resistance
/UL: UL approval, CE marking
Other Options
Span 0.1 – 1 V : ≥ 100 kΩ
blank: none
Span ≥ 1 V : ≥ 1 MΩ
/Q: Option other than the above (specify the specification)
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Minimum span: 1 mA
Offset: Max. 1.5 times span
/C02: Polyurethane coating
Load resistance: Output drive 15 V max.
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
/C03: Rubber coating (UL not available)
TERMINAL SCREW MATERIAL
/S01: Stainless steel (UL not available)
Offset: Max. 1.5 times span
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
GENERAL SPECIFICATIONS
Construction: Plug-in
INSTALLATION
Power Consumption
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
•AC:
Approx. 3 VA at 100 V
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Approx. 4 VA at 200 V
Approx. 5 VA at 264 V
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Ratio adjustment
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)
Proportional: 0.10 to 4.00; 0.01 increments
Inverted: -0.10 to -4.00; 0.01 increments
Bias adjustment: -100 to +100 %; 1 % increments
Ratio/bias selector: Double-throw SW (front)
UP/DOWN control: Double-throw, momentary SW (front)
Equation: X
= K (X + B) + 100 % (inverted)
where
: Output (%)
o
= K (X + B) (proportional)
i
Xo
i
Xo
K : Ratio
M2RTS SPECIFICATIONS
ES-5096 Rev.11 Page 2/5
http://www.m-system.co.jp/
MODEL: M2RTS
PERFORMANCE in percentage of span
Accuracy: ±0.2 %
Ratio = 1, Bias = 0 % (proportional)
Ratio = -1, Bias = 0 % (inverted)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: ≤ 0.5 sec. (0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
EN 50581
Approval:
UL/C-UL nonincendive Class I, Division 2,
Groups A, B, C, and D
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
UL/C-UL general safety requirements
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)
M2RTS SPECIFICATIONS
ES-5096 Rev.11 Page 3/5
http://www.m-system.co.jp/
MODEL: M2RTS
EXTERNAL VIEW
(A) Polarity Indicator LED
(B) Ratio/Bias Display
(C) Ratio/Bias Selector
Top: Ratio
Bottom: Bias
(D) UP/DOWN Control
(E) Zero Adj.
(F) Span Adj.
The front cover cannot be turned open by 180 deg.
when there is no extra space between units.
• How to Set the Ratio
Turn the Ratio/Bias Selector (C) to the top.
The Ratio/Bias Display (B) shows the current ratio (0.10 –
4.00). Press UP/DOWN Control (D) until the display shows a
desired set value.
The Polarity Indicator LED (A) is red when the set value is in
positive range, green when in negative range.
• How to Set the Bias
Turn the Ratio/Bias Selector (C) to the bottom.
The Ratio/Bias Display (B) shows the current bias (0 –
100%). Press UP/DOWN Control (D) until the display shows
a desired set value.
The Polarity Indicator LED (A) is red when the set value is in
positive range, green when in negative range.
• Fine Calibration
Equation:
Xo = K(Xi + B) (proportional)
Xo = K(Xi + B) + 100 % (inverted)
1) Calculate the input signal Xi which results in 0 % output.
Apply the calculated input and adjust with Zero Adj. (E) the
output Xo to 0 %.
2) Calculate the input signal Xi which results in 100 %
output. Apply the calculated input and adjust with Span
Adj. (E) the output Xo to 100 %.
3) Apply the calculated zero point input again and check the
output Xo.
4) If the output has been shifted, go through (1) through (3)
again.
The unit is factory set and calibrated to the following ratio
and bias values.
Proportional characteristics: ratio (K) = 1, Bias (B) = 0 %
Inverted characteristics: ratio (K) = -1, Bias (B) = 0 %
M2RTS SPECIFICATIONS
ES-5096 Rev.11 Page 4/5
http://www.m-system.co.jp/
MODEL: M2RTS
EXTERNAL DIMENSIONS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
4
1
5
8
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
12
9
8–M3
SCREW
14 13
21.5 (.85) 7.3 (.29)
86.7 (3.41)
116.7 (4.59)
15 (.59)
[4 (.16)]
23 (.91)
• When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm (inch)
INPUT RESISTOR
(model: REM2)
4
1
5
8
12
9
14 13
Input shunt resistor attached
for current input.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
RATIO/BIAS
SELECTOR
UP/DOWN
SW
Z
S
Isolation
Low Drift
Amplifier
Digital
Computation
Output
Driver
+
–
+
1
4
5
8
9
*
INPUT
R
OUTPUT
POWER
–
12
13
14
U(+)
V(–)
Ratio/Bias
Display
Base Socket
*Input shunt resistor attached for current input.
Specifications are subject to change without notice.
M2RTS SPECIFICATIONS
ES-5096 Rev.11 Page 5/5
http://www.m-system.co.jp/
M2RTS-R-C3-R/N 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M2RTS-R-C3-R/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C3-R/UL | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C3-R2 | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C3-R2/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C3-R2/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C3-R2/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C3-R2/UL | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C4-M2 | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C4-M2/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2RTS-R-C4-M2/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 |
M2RTS-R-C3-R/N 相关文章
- 2024-11-08
- 22
- 2024-11-08
- 15
- 2024-11-08
- 16
- 2024-11-08
- 15