M2SED-513-P/UL 概述
Super-mini Signal Conditioners Mini-M Series
M2SED-513-P/UL 数据手册
通过下载M2SED-513-P/UL数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: M2SED
Super-mini Signal Conditioners Mini-M Series
SETPOINT 2 OUTPUT
3: Lo (coil energized at alarm)
DC ALARM
(thumbwheel switch adjustment)
[2] POWER INPUT
Functions & Features
AC Power
• Provides SPDT relay outputs at preset DC input levels
• Dual (Hi / Lo) trip
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
• Thumbwheel switch setpoint adjustments
• Enclosed relays
(90 – 264 V for UL)
DC Power
• Relays can be powered 110 V DC
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
Typical Applications
• Annunciator
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
• Various alarm applications
29.5 (1.16)
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)
76
(2.99)
4
3
4
1
[3] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE or UL
/CE: CE marking
124
(4.88)
/UL: UL approval, CE marking
Other Options
mm (inch)
blank: none
/Q: Option other than the above (specify the specification)
MODEL: M2SED–[1]13–[2][3]
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
ORDERING INFORMATION
• Code number: M2SED-[1]13-[2][3]
Specify a code from below for each of [1] through [3].
(e.g. M2SED-613-P/CE/Q)
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
TERMINAL SCREW MATERIAL
• Specify the specification for option code /Q
(e.g. /C01/S01)
/S01: Stainless steel (UL not available)
Note: Must be used with its socket. NOT installable to a
multi-unit installation base. (e.g. model: M2BS-16)
GENERAL SPECIFICATIONS
Construction: Plug-in
[1] INPUT
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
Current
A: 4 – 20 mA DC (Input resistance 250 Ω)
Voltage
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
Setpoint adjustments: Thumbwheel switches (front);
0 – 99 % independently; 1 % increments
Hysteresis (deadband): 1 ± 0.3 %
SETPOINT 1 OUTPUT
1: Hi (coil energized at alarm)
Front LEDs: Red light turns on when the coil is energized.
INPUT SPECIFICATIONS
■ DC Current:
Shunt resistor attached to the input terminals (0.5 W)
M2SED SPECIFICATIONS
ES-5042 Rev.16 Page 1/4
http://www.m-system.co.jp/
MODEL: M2SED
Low Voltage Directive
EN 61010-1
OUTPUT SPECIFICATIONS
■ Relay Contact:
Measurement Category II (output)
Installation Category II (power)
Pollution Degree 2
100 V AC @5 A (cos ø = 1)
120 V AC @5 A (cos ø = 1)
240 V AC @2.5 A (cos ø = 1)
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
30 V DC @5 A (resistive load)
Maximum switching voltage: 250 V AC or 125 V DC
Maximum switching power: 600 VA or 150 W
Minimum load: 5 V DC @10 mA
EN 50581
Approval:
Mechanical life: 5 × 10
7
cycles
UL/C-UL general safety requirements
(UL 61010B-1, CAN/CSA-C22.2 No.1010-1)
Alarm Trip Operation
Terminal No. in parentheses
(3–6)ON
(3–9)ON
Output 1
(5–7)ON
Output 2
(5–8)ON
Input
(%)
0
▲
50
▲
100
Setpoint 2
Setpoint 1
Trip Operation in Power Failure: Terminals 3 – 9 and 5 – 8 turn on.
INSTALLATION
Power Consumption
•AC:
Approx. 3 VA at 100 V
Approx. 4 VA at 200 V
Approx. 5 VA at 264 V
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Installation Base (model: M2BS) is not adaptable.
Weight: 150 g (0.33 lb)
PERFORMANCE in percentage of span
Setpoint accuracy: ±0.5 %
Trip point repeatability: ±0.05 %
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: 0.5 ± 0.2 sec. (0 – 100 % at 90 % setpoint)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
M2SED SPECIFICATIONS
ES-5042 Rev.16 Page 2/4
http://www.m-system.co.jp/
MODEL: M2SED
FRONT VIEW
• Setpoint Adj.
Output 1
9
9
Output 2
9
9
• Monitor LED
Output 1
The front cover cannot be
turned open by 180 deg.
when there is no extra space
between units.
Output 2
EXTERNAL DIMENSIONS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
3
2
5
1
4
6
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
9
8
7
11–M3
SCREW
11 10
21.5 (.85) 7.3 (.29)
86.7 (3.41)
116.7 (4.59)
22 (.87)
[4 (.16)]
29.5 (1.16)
• When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm (inch)
INPUT RESISTOR
(model: REM2)
3
2
5
1
4
6
9
8
7
11 10
Input shunt resistor attached
for current input.
M2SED SPECIFICATIONS
ES-5042 Rev.16 Page 3/4
http://www.m-system.co.jp/
MODEL: M2SED
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
THUMBWHEEL
SWITCHES
Converter
Comparator
9 9
N.C.
N.O.
COM
N.C.
N.O.
COM
9
6
3
8
7
5
Low Drift
Amplifier
Ry
Ry
+
–
1
2
4
*
OUTPUT 1
INPUT
R
OUTPUT 2
POWER
THUMBWHEEL
SWITCHES
Converter
9 9
10 U(+)
11 V(–)
Base Socket
* Input shunt resistor attached for current input.
■ Relay Protection
• AC Powered
• DC Powered
Inductive
Load (Coil)
Inductive
Load (Coil)
Varistor or
CR Circuit
Diode, Varistor or
CR Circuit
LOAD
LOAD
U
Specifications are subject to change without notice.
M2SED SPECIFICATIONS
ES-5042 Rev.16 Page 4/4
http://www.m-system.co.jp/
M2SED-513-P/UL 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M2SED-513-R | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R/UL | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R2 | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R2/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R2/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R2/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2SED-513-R2/UL | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 |
M2SED-513-P/UL 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8