M2SP-2D-R2 [MSYSTEM]

Super-mini Signal Conditioners Mini-M Series;
M2SP-2D-R2
型号: M2SP-2D-R2
厂家: M-SYSTEM    M-SYSTEM
描述:

Super-mini Signal Conditioners Mini-M Series

文件: 总3页 (文件大小:106K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: M2SP  
Voltage  
Super-mini Signal Conditioners Mini-M Series  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
LOW FREQUENCY TRANSMITTER  
(50 Hz minimum)  
Functions & Features  
• Converts the output from a pulse-type transducer  
into a standard process signal  
Typical Applications  
[3] POWER INPUT  
AC Power  
• Positive displacement flowmeters, turbine flowmeters and  
vortex flowmeters  
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
• Proximity switches  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
23 (.91)  
(90 – 264 V for UL)  
Model  
76  
(2.99)  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R2: 11 – 27 V DC  
ZERO  
SPAN  
124  
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
P: 110 V DC  
(4.88)  
mm (inch)  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
(110 V ±10 % for UL)  
MODEL: M2SP-[1][2]-[3][4]  
[4] OPTIONS (multiple selections)  
Low-end Cutout  
ORDERING INFORMATION  
• Code number: M2SP-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. M2SP-1A-M2/CE/Q)  
blank: With  
/DN: Without  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
Standards & Approvals (must be specified)  
/N: Without CE or UL  
• Frequency range (e.g. 0 – 10 kHz)  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
/CE: CE marking  
/UL: UL approval, CE marking  
Other Options  
[1] INPUT  
1: Dry contact  
2: Voltage pulse  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
[2] OUTPUT  
Current  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
/C02: Polyurethane coating  
/C03: Rubber coating (UL not available)  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel (UL not available)  
M2SP SPECIFICATIONS  
ES-5056 Rev.20 Page 1/3  
http://www.m-system.co.jp/  
MODEL: M2SP  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
INSTALLATION  
Power Consumption  
AC:  
Connection: M3 screw terminals (torque 0.8 N·m)  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Approx. 4 VA at 100 V  
Approx. 5 VA at 200 V  
Approx. 6 VA at 264 V  
DC: Approx. 3 W  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Overrange output: 0 to 120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Input pulse sensing: DC coupled; detecting pulse rise  
Input filter: Provided with input range < 100 Hz  
(time constant approx. 1 msec.)  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 150 g (0.33 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 % (output 10 – 100 %)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: (0 – 90%)  
Low-end cutout: 2 to 5 %  
(For /DN option, the output signal may fluctuate when the  
input signal is less than 5 %.)  
Approx. 1.8 sec. with 0 – 50 Hz  
INPUT SPECIFICATIONS  
Excitation: 12 V DC @30 mA; shortcircuit protection  
Frequency range: 0 – 50 Hz through 10 kHz  
Dry Contact: Mechanical contact or open collector  
Pulse width time requirement: 20 μsec. min. for ON and OFF  
≥ 5 msec. with input range < 100 Hz  
Sensing: Approx. 12 V DC @3 mA  
ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2.5 V for  
OFF  
Approx. 0.7 sec. with 0 – 100 Hz  
Approx. 0.5 sec. with 0 – 500 Hz  
Approx. 0.5 sec. with 0 – 10 kHz  
Ripple: 0.2 %p-p max. with input ≥ 10 %  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
Voltage Pulse: Square or sine waveforms  
Pulse width time requirement: 20 μsec. min. for high and  
low levels  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
≥ 5 msec. with input range < 100 Hz  
Hi level: 2 – 50 V  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Lo level: ≤ 1 V  
Low Voltage Directive  
Input impedance: 10 kΩ min.  
EN 61010-1  
Installation Category II  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Pollution Degree 2  
Input or output to power: Reinforced insulation (300 V)  
Input to output: Basic insulation (300 V)  
RoHS Directive  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: 0 – 12 V DC  
EN 50581  
Approval:  
Minimum span: 5 mV  
UL/C-UL nonincendive Class I, Division 2,  
Groups A, B, C, and D  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V  
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)  
UL/C-UL general safety requirements  
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)  
M2SP SPECIFICATIONS  
ES-5056 Rev.20 Page 2/3  
http://www.m-system.co.jp/  
MODEL: M2SP  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
6 (.23)  
DIN RAIL  
35mm wide  
4
1
5
8
2–4.2x5  
(.17x.20)  
MTG HOLE  
6 (.24) deep  
12  
9
8–M3  
SCREW  
14 13  
21.5 (.85) 10 (.39)  
84 (3.31)  
114 (4.49)  
15 (.59)  
[4 (.16)]  
23 (.91)  
• When mounting, no extra space is needed between units.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Z
S
Isolation  
Waveform  
Shaper  
Output  
Driver  
+
1
4
5
8
9
+
One-Shot  
Smoother  
INPUT  
OUTPUT  
POWER  
12  
13  
14  
SENSOR EXCITATION  
+
12V Supply  
U(+)  
V(–)  
Base Socket  
Input Connection Examples  
Dry Contact  
Voltage Pulse  
+
+
1
4
5
+
+
1
4
5
+12V  
+12V  
PWR  
PWR  
4kΩ  
Specifications are subject to change without notice.  
M2SP SPECIFICATIONS  
ES-5056 Rev.20 Page 3/3  
http://www.m-system.co.jp/  

相关型号:

M2SP-2D-R2/CE

Super-mini Signal Conditioners Mini-M Series
MSYSTEM

M2SP-2D-R2/DN

Super-mini Signal Conditioners Mini-M Series
MSYSTEM

M2SP-2D-R2/N

Super-mini Signal Conditioners Mini-M Series
MSYSTEM

M2SP-2D-R2/Q

Super-mini Signal Conditioners Mini-M Series
MSYSTEM

M2SP-2D-R2/UL

Super-mini Signal Conditioners Mini-M Series
MSYSTEM

M2T

Triple-Balanced Mixer
TE

M2T12S4A5A03

Process Sealed Miniature Toggles
NKK

M2T12S4A5A05

Process Sealed Miniature Toggles
NKK

M2T12S4A5A06

Process Sealed Miniature Toggles
NKK

M2T12S4A5A07

Process Sealed Miniature Toggles
NKK

M2T12S4A5A13

Process Sealed Miniature Toggles
NKK

M2T12S4A5A30

Process Sealed Miniature Toggles
NKK