M2VF-5WA-R/X1 概述
Super-mini Signal Conditioners Mini-M Series
M2VF-5WA-R/X1 数据手册
通过下载M2VF-5WA-R/X1数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: M2VF
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
Super-mini Signal Conditioners Mini-M Series
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
01: Specify voltage (See INPUT SPECIFICATIONS)
(Select ‘/CE’ or ‘/UL’ for ‘Standards & Approvals’ code.)
SIGNAL TRANSMITTER
(high speed response)
Functions & Features
• Converts DC input from a sensor into a standard
process signal
• Isolation between input and output
• 180-microsecond response
[2] OUTPUT
Current
Typical Applications
A: 4 – 20 mA DC (Load resistance 750 Ω max.)
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)
D: 0 – 20 mA DC (Load resistance 750 Ω max.)
E: 0 – 16 mA DC (Load resistance 900 Ω max.)
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)
FW: -10 – +10 mA DC (Load resistance 700 Ω max.)
GW: -1 – +1 mA DC (Load resistance 7000 Ω max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
• Isolation for a vibration analyzing system
23 (.91)
Model
76
(2.99)
ZERO
SPAN
124
(4.88)
mm (inch)
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 1000 Ω min.)
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
MODEL: M2VF–[1][2]–[3][4]
ORDERING INFORMATION
• Code number: M2VF-[1][2]-[3][4]
Specify a code from below for each [1] through [4].
(e.g. M2VF-6A-M2/CE/Q)
• Special input and output ranges (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/V01)
[3] POWER INPUT
AC Power
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
[1] INPUT
Current
(Select ‘/N’ for ‘Standards & Approvals’ code.)
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
A: 4 – 20 mA DC (Input resistance 250 Ω)
B: 2 – 10 mA DC (Input resistance 500 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 50 Ω)
E: 0 – 16 mA DC (Input resistance 62.5 Ω)
F: 0 – 10 mA DC (Input resistance 100 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
GW: -1 – +1 mA DC (Input resistance 1000 Ω)
FW: -10 – +10 mA DC (Input resistance 100 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
(90 – 264 V for UL)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
M2VF SPECIFICATIONS
ES-5014 Rev.20 Page 1/6
http://www.m-system.co.jp/
MODEL: M2VF
Load resistance: Output drive 15 V max.;
[4] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE or UL
7 V for bidirectional outputs
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
/CE: CE marking
Offset: Max. 1.5 times span
/UL: UL approval, CE marking
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
Custom specification
(Refer to the custom specification list for difference
of specification and combination of code numbers.)
blank: none
INSTALLATION
Power Consumption
/X1: Response time (CE or UL not available)
/X2: Input (CE or UL not available)
Other Options
•AC:
Approx. 3 VA at 100 V
Approx. 4 VA at 200 V
blank: none
Approx. 5 VA at 264 V
/Q: Option other than the above (specify the specification)
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
ADJUSTMENT
PERFORMANCE in percentage of span
Accuracy: ±0.1 %
/V01: Multi-turn fine adjustment (UL not available)
TERMINAL SCREW MATERIAL
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: ≤ 180 μsec. (0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength:
/S01: Stainless steel (UL not available)
GENERAL SPECIFICATIONS
Construction: Plug-in
1000 V AC @1 minute (input to output)
2000 V AC @1 minute (input or output to power to ground)
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
STANDARDS & APPROVALS
EU conformity:
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
EMC Directive
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
INPUT SPECIFICATIONS
■ DC Current:
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Functional insulation (300 V)
RoHS Directive
Shunt resistor attached to the input terminals (0.5 W)
Specify input resistance value for code Z.
■ DC Voltage: -300 – +300 V DC
(-30 – +30 V for the input code 01. Span 60 V max.)
Minimum span: 1 V
EN 50581
Approval:
UL/C-UL nonincendive Class I, Division 2,
Groups A, B, C, and D
Offset: Max. 1.5 times span
Input resistance: ≥ 1 MΩ
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
UL/C-UL general safety requirements
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)
OUTPUT SPECIFICATIONS
■ DC Current: -10 – +20 mA DC
Minimum span: 1 mA
Offset: Max. 1.5 times span
M2VF SPECIFICATIONS
ES-5014 Rev.20 Page 2/6
http://www.m-system.co.jp/
MODEL: M2VF
EXTERNAL DIMENSIONS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
4
1
5
8
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
12
9
8–M3
SCREW
14 13
21.5 (.85) 10 (.39)
84 (3.31)
114 (4.49)
15 (.59)
[4 (.16)]
23 (.91)
• When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm (inch)
INPUT RESISTOR
(model: REM2)
4
1
5
8
12
9
14 13
Input shunt resistor attached
for current input.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Z
S
Isolation
Low Drift
Amplifier
Output
Driver
+
–
+
1
4
5
8
9
*
SIGNAL SOURCE
R
OUTPUT
POWER
–
12
13
14
U(+)
V(–)
Base Socket
*Input shunt resistor attached for current input.
The M2VF, by its fast-response feature, is not designed to eliminate noise present in the input signal.
Use a shielded twisted-pair cable for preventing noise entering through the input wiring.
Specifications are subject to change without notice.
M2VF SPECIFICATIONS
ES-5014 Rev.20 Page 3/6
http://www.m-system.co.jp/
MODEL: M2VF
CUSTOM SPECIFICATION LIST
Refer to the following pages for each detailed custom specification.
Custom specification: Option /X1
■ Major specification changes
Response time: 5.3 ms ±30 % (0 – 90 %)
Custom specification: Option /X2
■ Major specification changes
Input: 0 - 0.5 V DC (Input resistance 200 kΩ min.)
M2VF SPECIFICATIONS
ES-5014 Rev.20 Page 4/6
http://www.m-system.co.jp/
MODEL: M2VF
CUSTOM SPECIFICATION : OPTION /X1
Major specification changes
Response time: 5.3 msec. ±30 %
MODEL: M2VF–4W4W–[3]/N/X1[4]
Same as standard specification (without customization)
except followings.
Refer to standard specification pages.
ORDERING INFORMATION
• Code number: M2VF-4W4W-[3]/N/X1[4]
For [3] and [4] same code as standard specification is
available.
(e.g. M2VF-4W4W-M2/N/X1/Q)
Refer to standard specification pages.
SPECIFICATION CHANGES
■ Performance in percentage of span
Response time: 5.3 msec. ±30 % (0 – 90 %)
M2VF SPECIFICATIONS
ES-5014 Rev.20 Page 5/6
http://www.m-system.co.jp/
MODEL: M2VF
CUSTOM SPECIFICATION : OPTION /X2
Major specification changes
Input: 0 - 0.5 V DC (input resistance 200 kΩ)
MODEL: M2VF–0[2]–[3]/N/X2[4]
Same as standard specification (without customization)
except followings.
Refer to standard specification pages.
ORDERING INFORMATION
• Code number: M2VF-0[2]-[3]/N/X2[4]
For each each [2] through [4] same code as standard
specification is available.
(e.g. M2VF-04W-M2/N/X2/Q)
Refer to standard specification pages.
SPECIFICATION CHANGES
■ Input specifications
• Input 0 - 0.5 V DC
• Input resistance: 200 kΩ min.
M2VF SPECIFICATIONS
ES-5014 Rev.20 Page 6/6
http://www.m-system.co.jp/
M2VF-5WA-R/X1 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M2VF-5WA-R2 | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-R2/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-R2/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-R2/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-R2/UL | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-R2/X1 | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-RM | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-RM/CE | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-RM/N | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 | |
M2VF-5WA-RM/Q | MSYSTEM | Super-mini Signal Conditioners Mini-M Series | 获取价格 |
M2VF-5WA-R/X1 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8