M6DBS-08P/UL [MSYSTEM]

Euro Terminal Ultra-Slim Signal Conditioners M6D Series;
M6DBS-08P/UL
型号: M6DBS-08P/UL
厂家: M-SYSTEM    M-SYSTEM
描述:

Euro Terminal Ultra-Slim Signal Conditioners M6D Series

文件: 总5页 (文件大小:268K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: M6DBS  
Euro Terminal Ultra-Slim Signal Conditioners M6D Series  
RELATED PRODUCTS  
• M6D series signal conditioners (Not able to supply to AC  
power signal conditioners (M2 code))  
INSTALLATION BASE  
Functions & Features  
• Power supply module (model: M6DPS1)  
• Power supply module (model: M6DPS2)  
• Power supply module (model: M6-PSM)  
• Blank filler module (model: M6DDM)  
• Backplane to collectively supply power to the M6D  
modules in combination with the Power Supply Module  
(model: M6DPSx or M6-PSM)  
GENERAL SPECIFICATIONS  
Capacity: Up to 48 modules (including power supply  
module) with Extension Bases (The usable number of signal  
conditioners depends on the capacity of the power supply  
module. Refer to the M6-PSM specification sheets.)  
Isolation: Power to ground  
INSTALLATION  
Operating temperature: -20 to +55°C (-4 to +131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Surface or DIN rail  
MODEL: M6DBS–[1][2]  
Weight:  
ORDERING INFORMATION  
• Code number: M6DBS-[1][2]  
Specify a code from below for each [1] and [2].  
(e.g. M6DBS-08/UL/Q)  
M6DBS-08, -08P: 50 g (1.8 oz) without signal conditioners  
M6DBS-08A: 80 g (2.8 oz) without signal conditioners  
• Specify the specification for option code /Q  
(e.g. /C01)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (power to ground)  
[1] NUMBER OF SLOTS  
08: 8 slots  
STANDARDS & APPROVALS  
EU conformity:  
08P: 8 slots (for extension)  
08A: 8 slots + power supply slot (for model M6-PSM)  
(UL not available)  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
[2] OPTIONS (multiple selections)  
Standards & Approvals  
EN 50581  
Approval:  
blank: CE marking  
UL/C-UL nonincendive Class I, Division 2,  
Groups A, B, C, and D  
/UL: UL approval, CE marking  
Other Options  
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)  
UL/C-UL general safety requirements  
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
Only solder side of the main PWB is coated.  
/C01: Silicone coating  
/C02: Polyurethane coating  
M6DBS SPECIFICATIONS  
ES-7845 Rev.11 Page 1/5  
http://www.m-system.co.jp/  
MODEL: M6DBS  
EXTERNAL VIEW  
Install signal conditioners from the slot at either end.  
Power Supply Modules (M6DPS1 or M6DPS2) could be mounted at any slots, however,  
installing them at either end is generally recommended.  
Mount the power supply module (M6-PSM) on the power module slot of M6DBS-08A.  
M6DBS-08, M6DBS-08P  
M6DBS-08A  
Signal Conditioner or  
Power Supply Module  
Power Supply  
Module  
Signal  
Conditioner  
1 2 • • • •  
8
1 2  
8
• • • •  
M6DBS SPECIFICATIONS  
ES-7845 Rev.11 Page 2/5  
http://www.m-system.co.jp/  
MODEL: M6DBS  
EXTERNAL DIMENSIONS unit: mm (inch)  
M6DBS-08, M6DBS-08P  
[5 (.20)]  
27 (1.06)  
11.5 (.45)  
49 (1.93)  
24.4 (.96)  
[3 (.12)]  
3–4.5 (.18) dia. MTG HOLE  
2 (.08) deep  
DIN RAIL  
35mm wide  
22.5 (.89)  
37 (1.46)  
116 (4.57)  
M6DBS-08A  
[3 (.12)]  
[5 (.20)]  
3 (.12)  
72 (2.83)  
27 (1.06)  
24.4 (.96)  
3–4.5 (.18) dia. MTG HOLE  
2 (.08) deep  
DIN RAIL  
35mm wide  
37 (1.46)  
22.5 (.89)  
116 (4.57)  
M6DBS SPECIFICATIONS  
ES-7845 Rev.11 Page 3/5  
http://www.m-system.co.jp/  
MODEL: M6DBS  
MOUNTING REQUIREMENTS unit: mm (inch)  
■ MOUNTING DIRECTION  
The unit must be mounted on a vertical panel. Mounting in any other angle will cause internal temperature to rise,  
may shorten the product’s life expectation or deteriorate its performance.  
Panel ceiling or wiring conduit (height ≤ 50 mm or 2 in.)  
M6DBS  
10  
10  
(.39)  
(.39)  
Panel bottom or wiring conduit (height ≤ 50 mm or 2 in.)  
■ SURFACE MOUNTING  
• M6DBS-08  
• M6DBS-08A  
24.4 (.96)  
3-M4  
3-M4  
37 (1.46)  
37 (1.46)  
• M6DBS-08 + M6DBS-08P  
• M6DBS-08A + M6DBS-08P  
24.4 (.96)  
1
1
n-M4  
*
n-M4 *  
37 (1.46)  
37 (1.46)  
37 (1.46)  
37 (1.46)  
11.8 (.46)  
11.8  
(.46)  
*1. n = (Number of bases) x 3  
M6DBS SPECIFICATIONS  
ES-7845 Rev.11 Page 4/5  
http://www.m-system.co.jp/  
MODEL: M6DBS  
Specifications are subject to change without notice.  
M6DBS SPECIFICATIONS  
ES-7845 Rev.11 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

M6DDY

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-4-R

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-4-R/Q

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-4-R/UL

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-5-R

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-5-R/Q

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-5-R/UL

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-6-R

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-6-R/Q

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-6-R/UL

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-A-R

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM

M6DDY-A-R/Q

Euro Terminal Ultra-Slim Signal Conditioners M6D Series
MSYSTEM