MODEL: MD72W
Lightning Surge Protectors for
Electronics Equipment M-RESTER
[2] LOOP DISCONNECT FUSE
0: Without
1: With (CENELEC intrinsic safety (ATEX) not available)
LIGHTNING SURGE PROTECTOR FOR
[3] SAFETY APPROVAL
0: None
TWO-WIRE SIGNAL LOOP
(ultra-slim)
2: CENELEC intrinsic safety (ATEX)
Functions & Features
• High discharge current capacity 20 kA (8 / 20μs), 1 kA (10
/ 350 μs)
[4] OPTIONS
• Ultra-thin 7-mm-wide module can be mounted
in high density
blank: none
/Q: With options (specify the specification)
(CENELEC intrinsic safety (ATEX) not available)
• Excellent protection employing multi-stage SPD circuits
• DIN rail mounting and grounding
• Loop disconnect fuse
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Typical Applications
• Protecting a 2-wire transmitter loop
• Protecting an electronic device I/O
/C02: Polyurethane coating
RELATED PRODUCTS
• Loop disconnect fuse (model: MD7F)
7 (.28)
GENERAL SPECIFICATIONS
Construction: Slim-sized front terminal structure
Degree of protection: IP20
95
(3.74)
Connection: Euro terminal block (torque 0.3 N·m)
Applicable wire size: 0.2 – 2.5 mm2, stripped length 8 mm
Grounding: DIN Rail
98
(3.86)
Housing material: Flame-resistant resin (black)
Loop disconnect fuse: Current rating 250 mA
mm (inch)
INSTALLATION
MODEL: MD72W–[1][2][3][4]
Operating temperature: -25 to +85°C (-13 to +185°F)
(See Safety Parameters for use in a hazardous location.)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)
Oxide film on the surface of an aluminium DIN rail may
lower the electric conductivity between this module and the
ground. Use a steel or copper rail.
ORDERING INFORMATION
• Code number: MD72W-[1][2][3][4]
Specify a code from below for each [1] through [4].
(e.g. MD72W-5500/Q)
For the safety approval code 2, specify the product’s
destination country using Ordering Information Sheet (No.
ESU-8057).
Weight: 70 g (2.5 oz)
• Specify the specification for option code /Q
(e.g. /C01)
[1] NOMINAL VOLTAGE
07: 7 V DC
16: 16 V DC
32: 32 V DC
55: 55 V DC
MD72W SPECIFICATIONS
ES-8051 Rev.8 Page 1/4
http://www.m-system.co.jp/
MODEL: MD72W
PERFORMANCE
MODEL NO.
MD72W-07
7ꢀ
MD72W-16
16ꢀ
MD72W-32
MD72W-55
55ꢀ
Max. continuous operating voltage (Uc)
Line to Line
Line to Earth
Line to Line
Line to Earth
Line to Line
Other sections
Line to Line
Other sections
32ꢀ
32ꢀ
7ꢀ
16ꢀ
55ꢀ
ꢀoltage protection level (Up)
@6kꢀ (1.2 / 50 µs)
20ꢀ
30ꢀ
50ꢀ
80ꢀ
30ꢀ
40ꢀ
60ꢀ
90ꢀ
Leakage current @Uc
≤ 10µA
≤ 10µA
≤ 5µA
≤ 5µA
Response time
≤ 4 nsec.
≤ 4 nsec.
Max. discharge current (Imax)
20kA (8 / 20 µs), 1.0kA (10 / 350 µs)
400mA
N
Nominal current (I )
Without fuse
With fuse
250mA
Internal series resistance
Surge protection
Without fuse
With fuse
2.2Ω 20ꢁ per line
4Ω 20ꢁ per line
IEC 61643-21 Categories C1, C2, D1
STANDARDS & APPROVALS
EU conformity:
ATEX Directive
Ex ia EN 60079-11
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
Safety approval:
CENELEC: Intrinsic safety (ATEX)
II 1G, Ex ia IIC; T4 and T5
EN 60079-0
EN 60079-11
SAFETY PARAMETERS
■ CENELEC / ATEX IS DATA
MD72W-07 MD72W-16 MD72W-32 MD72W-55
Ui (Vmax)
7V
16V
32V
60V
150mA
5 nF
Ii (Imax)
150mA
50 nF
150mA
35 nF
150mA
10 nF
Ci
Li
150 µH
Temp. Class
150 µH
150 µH
150 µH
Parameter
1.3W
Range
-25 to +40°C
-25 to +60°C
-25 to +80°C
-25 to +40°C
Pi
T4
T5
1.2W
1.0W
1.0W
MD72W SPECIFICATIONS
ES-8051 Rev.8 Page 2/4
http://www.m-system.co.jp/
MODEL: MD72W
DESCRIPTIONS
• Specify ‘Loop disconnect fuse’ type when multiple transmitters are connected to a single power bus.
• Loop disconnect fuse is used to separate a transmitter loop from the power bus when it fails in shortcircuit mode.
Fuse/Disconnect
DC Power Supply
M-RESTER
4 – 20mA Field-mount
Transmitter Surge Protector
+
–
+
–
4
1
2
5
250Ω
(model: MD6x)
8
7
DIN RAIL
ADAPTOR
DIN RAIL
Power Bus
To other 4 – 20mA loops
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
8–M3 EURO
WIRE INSERTION ANGLE: approx. 20°
TERMINAL
8
6
5
4
8
DIN RAIL
ADAPTOR
6
5
DIN RAIL
4
(35 mm wide)
LOOP DISCONNECT
FUSE (option)
1
2
3
7
1
2
3
7
[1.5 (.05)]
98 (3.86)
7
(.28)
MD72W SPECIFICATIONS
ES-8051 Rev.8 Page 3/4
http://www.m-system.co.jp/
MODEL: MD72W
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
*4
Fuse/Disconnect
4 – 20mA Field-mount
Transmitter Surge Protector
Current Loop
Supply
Surge Side
4
Protected Side
1
+
+
DISCHARGE
ELEMENT
–
–
5
6
8
2
3
7
FG
(model: MD6x)
DIN RAIL ADAPTOR
(for grounding)
*3
*1
Crossover Wire
DIN RAIL
*2
Grounding
*1. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground.
Use a steel or copper rail.
*2. Be sure to ground the DIN rail. Recommended grounding resistance ≤100Ω
*3. Cross-wire between the DIN rail or the terminal 7 and the metal housing of the protected device to equalize
the earth potential. Ground only the surge protector when the protected device has no ground terminal.
Without Fuse/Disconnect option, fuse circuit is shorted.
*4.
Specifications are subject to change without notice.
MD72W SPECIFICATIONS
ES-8051 Rev.8 Page 4/4
http://www.m-system.co.jp/
相关型号: