MD73W-322/Q [MSYSTEM]
Lightning Surge Protectors for Lightning Surge Protectors for;型号: | MD73W-322/Q |
厂家: | M-SYSTEM |
描述: | Lightning Surge Protectors for Lightning Surge Protectors for |
文件: | 总3页 (文件大小:122K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: MD73W
Lightning Surge Protectors for
Electronics Equipment M-RESTER
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
(CENELEC intrinsic safety (ATEX) not available)
LIGHTNING SURGE PROTECTOR FOR
THREE-WIRE SIGNAL LOOP
(ultra-slim)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Functions & Features
• High discharge current capacity 20 kA (8 / 20 μs), 1 kA (10
/ 350 μs)
/C02: Polyurethane coating
• Ultra-thin 7-mm-wide module can be mounted
in high density
GENERAL SPECIFICATIONS
Construction: Slim-sized front terminal structure
Degree of protection: IP20
• Excellent protection employing multi-stage SPD circuits
• DIN rail mounting and grounding
Connection: Euro terminal block (torque 0.3 N·m)
Typical Applications
Applicable wire size: 0.2 – 2.5 mm2, stripped length 8 mm
• Protecting a 3-wire transmitter loop
• Protecting an electronic device I/O
Grounding: DIN Rail
Housing material: Flame-resistant resin (black)
INSTALLATION
7 (.28)
Operating temperature: -25 to +85°C (-13 to +185°F)
(See Safety Parameters for use in a hazardous location.)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)
Oxide film on the surface of an aluminium DIN rail may
lower the electric conductivity between this module and the
ground. Use a steel or copper rail.
95
(3.74)
Weight: 70 g (2.5 oz)
98
(3.86)
mm (inch)
PERFORMANCE
Max. continuous operating voltage (Uc):
Line to line: ±32 V
MODEL: MD73W–32[1][2]
Line to earth: ±32 V
Voltage protection level (Up) @ 6 kV (1.2 / 50 μs):
Line to line: ±60 V
ORDERING INFORMATION
• Code number: MD73W-32[1][2]
Specify a code from below for each [1] and [2].
(e.g. MD73W-320/Q)
Line to earth: ±60 V
Response time:
Line to line: ≤ 4 nsec.
Line to earth: ≤ 20 nsec.
Leakage current @Uc:
For the safety approval code 2, specify the product’s
destination country using Ordering Information Sheet (No.
ESU-8057).
Line to line: ≤ 5 μA
Line to earth: ≤ 5 μA
• Specify the specification for option code /Q
(e.g. /C01)
Max. discharge current (Imax): 20 kA (8 / 20 μs); 1.0 kA (10
/ 350 μs)
Nominal current (I ): 400 mA
N
NOMINAL VOLTAGE
32: 32 V DC
Internal series resistance: ≤ 2.2 Ω ±20 % per line
Surge protection: IEC 61643-21 Categories C1, C2, D1
[1] SAFETY APPROVAL
0: None
2: CENELEC intrinsic safety (ATEX)
MD73W SPECIFICATIONS
ES-8061 Rev.7 Page 1/3
http://www.m-system.co.jp/
MODEL: MD73W
STANDARDS & APPROVALS
EU conformity:
ATEX Directive
Ex ia EN 60079-11
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
Safety approval:
CENELEC: Intrinsic safety (ATEX)
II 1G, Ex ia IIC; T4 and T5
EN 60079-0
EN 60079-11
SAFETY PARAMETERS
■ CENELEC / ATEX IS DATA
Ui (Vmax)
32V
Ii (Imax)
150mA
Ci
Li
10 nF
150 µH
Temp. Class
Range
Parameter
1.3W
-25 to +40°C
-25 to +60°C
-25 to +80°C
-25 to +40°C
Pi
T4
T5
1.2W
1.0W
1.0W
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
8–M3 EURO
WIRE INSERTION ANGLE: approx. 20°
TERMINAL
8
6
5
4
8
DIN RAIL
ADAPTOR
6
5
DIN RAIL
4
(35 mm wide)
1
2
3
7
1
2
3
7
[1.5 (.06)]
98 (3.86)
7
(.28)
MD73W SPECIFICATIONS
ES-8061 Rev.7 Page 2/3
http://www.m-system.co.jp/
MODEL: MD73W
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Transmitter Protected Side
M-RESTER
Surge Side
Surge Side
M-RESTER
Protected Side
1
Receiver
*4
+
+
–
+
1
2
4
4
DISCHARGE
ELEMENT
DISCHARGE
ELEMENT
+
–
5
5
2
DISCHARGE
ELEMENT
DISCHARGE
ELEMENT
3
7
6
8
6
8
3
7
FG
FG
DIN RAIL ADAPTOR
(for grounding)
DIN RAIL ADAPTOR
(for grounding)
*3
Crossover Wire
*3
Crossover Wire
*1
*1
DIN RAIL
Grounding
DIN RAIL
*2
*2
Grounding
*1. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail.
*2. Be sure to ground the DIN rail. Recommended grounding resistance ≤100Ω
*3. Cross-wire between the DIN rail and the metal housing of the protected device to equalize the earth potential.
Ground only the surge protector when the protected device has no ground terminal.
*4. Install a circuit protector if the excitation supply rating is greater than the maximum load current of the surge protector.
Specifications are subject to change without notice.
MD73W SPECIFICATIONS
ES-8061 Rev.7 Page 3/3
http://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明