MODEL: MD73W  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
[2] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
(CENELEC intrinsic safety (ATEX) not available)  
LIGHTNING SURGE PROTECTOR FOR  
THREE-WIRE SIGNAL LOOP  
(ultra-slim)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Functions & Features  
• High discharge current capacity 20 kA (8 / 20 μs), 1 kA (10  
/ 350 μs)  
/C02: Polyurethane coating  
• Ultra-thin 7-mm-wide module can be mounted  
in high density  
GENERAL SPECIFICATIONS  
Construction: Slim-sized front terminal structure  
Degree of protection: IP20  
• Excellent protection employing multi-stage SPD circuits  
• DIN rail mounting and grounding  
Connection: Euro terminal block (torque 0.3 N·m)  
Typical Applications  
Applicable wire size: 0.2 – 2.5 mm2, stripped length 8 mm  
• Protecting a 3-wire transmitter loop  
• Protecting an electronic device I/O  
Grounding: DIN Rail  
Housing material: Flame-resistant resin (black)  
INSTALLATION  
7 (.28)  
Operating temperature: -25 to +85°C (-13 to +185°F)  
(See Safety Parameters for use in a hazardous location.)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)  
Oxide film on the surface of an aluminium DIN rail may  
lower the electric conductivity between this module and the  
ground. Use a steel or copper rail.  
95  
(3.74)  
Weight: 70 g (2.5 oz)  
98  
(3.86)  
mm (inch)  
PERFORMANCE  
Max. continuous operating voltage (Uc):  
Line to line: ±32 V  
MODEL: MD73W–32[1][2]  
Line to earth: ±32 V  
Voltage protection level (Up) @ 6 kV (1.2 / 50 μs):  
Line to line: ±60 V  
ORDERING INFORMATION  
• Code number: MD73W-32[1][2]  
Specify a code from below for each [1] and [2].  
(e.g. MD73W-320/Q)  
Line to earth: ±60 V  
Response time:  
Line to line: ≤ 4 nsec.  
Line to earth: ≤ 20 nsec.  
Leakage current @Uc:  
For the safety approval code 2, specify the product’s  
destination country using Ordering Information Sheet (No.  
ESU-8057).  
Line to line: ≤ 5 μA  
Line to earth: ≤ 5 μA  
• Specify the specification for option code /Q  
(e.g. /C01)  
Max. discharge current (Imax): 20 kA (8 / 20 μs); 1.0 kA (10  
/ 350 μs)  
Nominal current (I ): 400 mA  
N
NOMINAL VOLTAGE  
32: 32 V DC  
Internal series resistance: ≤ 2.2 Ω ±20 % per line  
Surge protection: IEC 61643-21 Categories C1, C2, D1  
[1] SAFETY APPROVAL  
0: None  
2: CENELEC intrinsic safety (ATEX)  
MD73W SPECIFICATIONS  
ES-8061 Rev.7 Page 1/3  
http://www.m-system.co.jp/  
MODEL: MD73W  
STANDARDS & APPROVALS  
EU conformity:  
ATEX Directive  
Ex ia EN 60079-11  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
EN 50581  
Safety approval:  
CENELEC: Intrinsic safety (ATEX)  
II 1G, Ex ia IIC; T4 and T5  
EN 60079-0  
EN 60079-11  
SAFETY PARAMETERS  
CENELEC / ATEX IS DATA  
Ui (Vmax)  
32V  
Ii (Imax)  
150mA  
Ci  
Li  
10 nF  
150 µH  
Temp. Class  
Range  
Parameter  
1.3W  
-25 to +40°C  
-25 to +60°C  
-25 to +80°C  
-25 to +40°C  
Pi  
T4  
T5  
1.2W  
1.0W  
1.0W  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
8–M3 EURO  
WIRE INSERTION ANGLE: approx. 20°  
TERMINAL  
8
6
5
4
8
DIN RAIL  
ADAPTOR  
6
5
DIN RAIL  
4
(35 mm wide)  
1
2
3
7
1
2
3
7
[1.5 (.06)]  
98 (3.86)  
7
(.28)  
MD73W SPECIFICATIONS  
ES-8061 Rev.7 Page 2/3  
http://www.m-system.co.jp/  
MODEL: MD73W  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Transmitter Protected Side  
M-RESTER  
Surge Side  
Surge Side  
M-RESTER  
Protected Side  
1
Receiver  
*4  
+
+
+
1
2
4
4
DISCHARGE  
ELEMENT  
DISCHARGE  
ELEMENT  
+
5
5
2
DISCHARGE  
ELEMENT  
DISCHARGE  
ELEMENT  
3
7
6
8
6
8
3
7
FG  
FG  
DIN RAIL ADAPTOR  
(for grounding)  
DIN RAIL ADAPTOR  
(for grounding)  
*3  
Crossover Wire  
*3  
Crossover Wire  
*1  
*1  
DIN RAIL  
Grounding  
DIN RAIL  
*2  
*2  
Grounding  
*1. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail.  
*2. Be sure to ground the DIN rail. Recommended grounding resistance ≤100Ω  
*3. Cross-wire between the DIN rail and the metal housing of the protected device to equalize the earth potential.  
Ground only the surge protector when the protected device has no ground terminal.  
*4. Install a circuit protector if the excitation supply rating is greater than the maximum load current of the surge protector.  
Specifications are subject to change without notice.  
MD73W SPECIFICATIONS  
ES-8061 Rev.7 Page 3/3  
http://www.m-system.co.jp/  

相关型号:

MD74R

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74R-FF

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74R-FF/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74R-FG

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74R-FG/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74SC240AC

Bus Driver, 2-Func, 4-Bit, Inverted Output, CMOS, CDIP20
MICROSEMI

MD74SC240AE

Bus Driver, 2-Func, 4-Bit, Inverted Output, CMOS, PDIP20
MICROSEMI

MD74SC241AC

Bus Driver, 2-Func, 4-Bit, True Output, CMOS, CDIP20,
ZARLINK

MD74SC241AE

Bus Driver, 2-Func, 4-Bit, True Output, CMOS, PDIP20
ZARLINK

MD74SC244AC

Bus Driver, 2-Func, 4-Bit, True Output, CMOS, CDIP20
ZARLINK

MD74SC373AC

D Latch, 1-Func, 8-Bit, CMOS, CDIP20,
MICROSEMI

MD74SC373AE

D Latch, 1-Func, 8-Bit, CMOS, PDIP20,
MICROSEMI